Experimental evaluation of attic radiant barriers

被引:0
|
作者
Al-Asmar, Husam R. [1 ]
Jones, Byron W. [1 ]
Matteson, Dennis K. [1 ]
机构
[1] Kansas State Univ, Manhattan, United States
来源
ASHRAE Transactions | 1996年 / 102卷 / 01期
关键词
Atmospheric temperature - Buildings - Cooling - Environmental chambers - Heat flux - Heat transfer - Mathematical models - Roofs - Thermal insulation - Ventilation;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the results of ASHRAE Research Project 577-RP, 'Attic Radiant Barrier Systems,' an experimental study to evaluate the impact of radiant barrier systems on summer cooling loads in residential buildings. A simulated attic was built inside the entire area of a 24-ft by 12-ft (7.3-m by 3.7-m) environmental chamber. A total of 72 steady-state experiments were conducted. Roof temperature varied from 120°F to 160°F (41°C to 71°C), attic ventilation varied from 0 to 2.0 cfm/ft2 (0.01 m3/s&middotm2), and nominal R-11 and R-19 (2.0 and 3.3 m2&middot°C/W) insulations were used in the experiments. Three radiant barrier configurations were used: under the roof deck between the rafters, directly over the ceiling insulation, and with no radiant barrier. Additional experiments were conducted to examine the movement of ventilation air inside the attic. The results show reductions in attic heat gains ranging from 17% to 26% with no ventilation and from 24% to 42% when the attic was ventilated. The location of the radiant barrier had little effect on ceiling heat gain. In addition to reducing ceiling heat gains, the radiant barrier mounted under the roof reduced attic temperatures 10°F to 15°F (6°C to 8°C) under typical conditions. The radiant barrier mounted over the ceiling insulation had a lesser effect on attic air temperature. Soffit-to-ridge ventilation was more effective in reducing ceiling heat gains than gable-to-gable ventilation.
引用
收藏
页码:297 / 306
相关论文
共 50 条
  • [21] Experimental Evaluation of an Innovative Command for Hydronic Radiant Heating Floors
    Silva, P. D.
    Gaspar, P. D.
    Batista, G.
    Domingues, C.
    4TH INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES (ICMEAT 2015), 2015, : 170 - 175
  • [22] Experimental evaluation of an active solar thermoelectric radiant wall system
    Liu, ZhongBing
    Zhang, Ling
    Gong, GuangCai
    Han, TianHe
    ENERGY CONVERSION AND MANAGEMENT, 2015, 94 : 253 - 260
  • [23] Experimental evaluation of thermal environment built by decoupled radiant cooling system with low radiant cooling temperature
    Guo, Yanling
    Du, Ke
    Wu, Huijun
    Li, Xuemei
    Huang, Huakun
    Liu, Jia
    Huang, Gongsheng
    Xu, Xinhua
    JOURNAL OF BUILDING ENGINEERING, 2024, 92
  • [24] Evaluation of heat flux reduction provided by the use of radiant barriers in clay tile roofs
    Michels, Caren
    Larnberts, Roberto
    Gueths, Saulo
    ENERGY AND BUILDINGS, 2008, 40 (04) : 445 - 451
  • [25] Experimental Evaluation of Circular Frequency Supply of Radiant Floor Heating System
    Cholewa, Tomasz
    Siuta-Olcha, Alicja
    ROCZNIK OCHRONA SRODOWISKA, 2015, 17 : 438 - 449
  • [26] Experimental evaluation of heat transfer coefficients between radiant ceiling and room
    Causone, Francesco
    Corgnati, Stefano P.
    Filippi, Marco
    Olesen, Bjarne W.
    ENERGY AND BUILDINGS, 2009, 41 (06) : 622 - 628
  • [27] Experimental evaluation on asymmetrical thermal sensation in modular radiant heating system
    Wang, Tianhui
    Liu, Yanfeng
    Wang, Dengjia
    Gao, Weijun
    BUILDING AND ENVIRONMENT, 2022, 222
  • [28] Experimental evaluation of a suspended metal ceiling radiant panel with inclined fins
    Zhang, Lun
    Liu, Xiao-Hua
    Jiang, Yi
    ENERGY AND BUILDINGS, 2013, 62 : 522 - 529
  • [29] Experimental evaluation of a cooling radiant wall coupled to a ground heat exchanger
    Romani, Joaquim
    Perez, Gabriel
    de Gracia, Alvaro
    ENERGY AND BUILDINGS, 2016, 129 : 484 - 490