Experimental evaluation on asymmetrical thermal sensation in modular radiant heating system

被引:8
|
作者
Wang, Tianhui [1 ,4 ]
Liu, Yanfeng [1 ,2 ]
Wang, Dengjia [1 ,2 ]
Gao, Weijun [3 ,4 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, Xian 710055, Peoples R China
[3] Qingdao Univ Technol, iSMART, Fushun Rd 11, Qingdao 266033, Peoples R China
[4] Univ Kitakyushu, Fac Environm Engn, Kitakyushu, Japan
基金
中国国家自然科学基金;
关键词
Modular radiant heating system; Asymmetric thermal sensation; Skin temperature differences; Asymmetric thermal environments; SKIN TEMPERATURE; SOLAR-RADIATION; COMFORT; ENVIRONMENT; FLOOR; RESPONSES; DESIGN; MODEL; COLD; ROOM;
D O I
10.1016/j.buildenv.2022.109433
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Modular radiant heating system has been widely used for heating during winter with the advantage of energy saving and meet thermal requirement. However, the asymmetry issues about thermal sensation would be often occurred because of the thermal radiation characteristics, and human thermal comfort would be affected by the position in relative to the radiant plate. How to solve asymmetrical thermal sensation will be an essential challenge to the popularization of radiant heating systems. This paper tries to evaluate the asymmetric thermal sensation of human body indoor at different exposure positions. Twenty volunteers were employed to investigate physiological and psychological situations during typical winter conditions. The experiment has assumed that the volunteers located at different positions to the radiant plate with different angles and vertical distance. Results illustrated that volunteers at different positions had different asymmetric thermal sensation because one side of the human body indoor was facing the radiant plate but the other was not. Besides, experimental data showed that the skin temperature difference was the biggest in upper arm, of 3 degrees C-4 degrees C. An asymmetric thermal sensation votes (ATSVs) was proposed to supplement the evaluation of the asymmetric thermal comfort, the highest difference values of all volunteers' ATSVs would get to 0.21, which were different with TSVs. Moreover, asymmetric skin temperature difference has a clear linear relationship with asymmetric thermal sensation vote, reflecting sensitivity of personnel at different positions to asymmetric thermal environments. The experimental results of this study can serve as a reference for thermal designs of buildings.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A review of local radiant heating systems and their effects on thermal comfort and sensation
    Hooshmand, Seyed Mohammad
    Zhang, Hui
    Javidanfar, Hashem
    Zhai, Yongchao
    Wagner, Andreas
    ENERGY AND BUILDINGS, 2023, 296
  • [2] Experimental Evaluation of Circular Frequency Supply of Radiant Floor Heating System
    Cholewa, Tomasz
    Siuta-Olcha, Alicja
    ROCZNIK OCHRONA SRODOWISKA, 2015, 17 : 438 - 449
  • [3] Experimental Evaluation of Radiant Heating Ceiling Systems Based on Thermal Comfort Criteria
    Safizadeh, M. Reza
    Schweiker, Marcel
    Wagner, Andreas
    ENERGIES, 2018, 11 (11)
  • [4] Experimental Evaluation of the Thermal Performance of Raised Floor Integrated Radiant Heating Panels
    Kim, Dong-Woo
    Joe, Goo-Sang
    Park, Sang-Hoon
    Yeo, Myoung-Souk
    Kim, Kwang-Woo
    ENERGIES, 2017, 10 (10):
  • [5] Thermal evaluation and optimization of a building heating system: radiant floor coupled with a solar system
    Simou Z.
    Hamdaoui S.
    Oubenmoh S.
    El Afou Y.
    Babaharra O.
    Mahdaoui M.
    Ait Msaad A.
    Journal of Building Pathology and Rehabilitation, 2024, 9 (1)
  • [6] Modular Radiant Floor Heating and its Effect on Local Thermal Comfort
    Houtart, Diego
    Jhang, Han-Yun
    Licina, Dusan
    Khovalyg, Dolaana
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 3, 2025, 554 : 110 - 116
  • [7] EXPERIMENTAL STUDY ON RADIANT FLOOR HEATING SYSTEM
    Ngo, C. C.
    Alhabeeb, B. A.
    Balestrieri, M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 8A, 2016,
  • [8] Experimental Study on Thermal Response Characteristics of Indoor Environment with Modular Radiant Cooling System
    Li, Zhengrong
    Zhang, Dongkai
    Li, Cui
    ENERGIES, 2020, 13 (19)
  • [9] Experimental evaluation of indoor thermal environment with modularity radiant heating in low energy buildings
    Li, Zhengrong
    Zhang, Dongkai
    Li, Cui
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 123 : 159 - 168
  • [10] Operation optimization of prefabricated light modular radiant heating system: Thermal resistance analysis and numerical study
    Li, Yao
    Hu, Ru-kun
    Xin, Li
    Xue, Jie
    Huang, Fei
    Xia, Jian-wei
    Yang, Xiao-hu
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2024, 31 (06) : 1983 - 1997