Experimental evaluation on asymmetrical thermal sensation in modular radiant heating system

被引:8
|
作者
Wang, Tianhui [1 ,4 ]
Liu, Yanfeng [1 ,2 ]
Wang, Dengjia [1 ,2 ]
Gao, Weijun [3 ,4 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, Xian 710055, Peoples R China
[3] Qingdao Univ Technol, iSMART, Fushun Rd 11, Qingdao 266033, Peoples R China
[4] Univ Kitakyushu, Fac Environm Engn, Kitakyushu, Japan
基金
中国国家自然科学基金;
关键词
Modular radiant heating system; Asymmetric thermal sensation; Skin temperature differences; Asymmetric thermal environments; SKIN TEMPERATURE; SOLAR-RADIATION; COMFORT; ENVIRONMENT; FLOOR; RESPONSES; DESIGN; MODEL; COLD; ROOM;
D O I
10.1016/j.buildenv.2022.109433
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Modular radiant heating system has been widely used for heating during winter with the advantage of energy saving and meet thermal requirement. However, the asymmetry issues about thermal sensation would be often occurred because of the thermal radiation characteristics, and human thermal comfort would be affected by the position in relative to the radiant plate. How to solve asymmetrical thermal sensation will be an essential challenge to the popularization of radiant heating systems. This paper tries to evaluate the asymmetric thermal sensation of human body indoor at different exposure positions. Twenty volunteers were employed to investigate physiological and psychological situations during typical winter conditions. The experiment has assumed that the volunteers located at different positions to the radiant plate with different angles and vertical distance. Results illustrated that volunteers at different positions had different asymmetric thermal sensation because one side of the human body indoor was facing the radiant plate but the other was not. Besides, experimental data showed that the skin temperature difference was the biggest in upper arm, of 3 degrees C-4 degrees C. An asymmetric thermal sensation votes (ATSVs) was proposed to supplement the evaluation of the asymmetric thermal comfort, the highest difference values of all volunteers' ATSVs would get to 0.21, which were different with TSVs. Moreover, asymmetric skin temperature difference has a clear linear relationship with asymmetric thermal sensation vote, reflecting sensitivity of personnel at different positions to asymmetric thermal environments. The experimental results of this study can serve as a reference for thermal designs of buildings.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] THE EFFECTS OF PANEL SURFACE TEMPERATURE ON THERMAL COMFORT IN A RADIANT HEATING SYSTEM
    Lin, Jie
    Chen, Chao
    Li, Qingqing
    Wu, Pin
    Zhang, Ye
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1128 - 1135
  • [32] Thermal performance analysis of a solar heating and nocturnal radiant cooling system
    Wang Yiping
    Yong, Cui
    Li, Zhu
    Kong Jianguo
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 546 - 550
  • [33] Numerical Model and Experimental Analysis of the Thermal Behavior of Electric Radiant Heating Panels
    Ferrarini, Giovanni
    Fortuna, Stefano
    Bortolin, Alessandro
    Cadelano, Gianluca
    Bison, Paolo
    Peron, Fabio
    Romagnoni, Piercarlo
    APPLIED SCIENCES-BASEL, 2018, 8 (02):
  • [34] Comparison of thermal comfort between convective heating and radiant heating terminals in a winter thermal environment: A field and experimental study
    Sun, Hongli
    Yang, Zixu
    Lin, Borong
    Shi, Wenxing
    Zhu, Yingxin
    Zhao, Haitian
    ENERGY AND BUILDINGS, 2020, 224 (224)
  • [35] Experimental study on the thermal comfort in the room equipped with a radiant floor heating system exposed to direct solar radiation
    Li, Tianying
    Merabtine, Abdelatif
    Lachi, Mohammed
    Martaj, Nadia
    Bennacer, Rachid
    ENERGY, 2021, 230
  • [36] Experimental study on the thermal performance of radiant floor heating system with the influence of solar radiation on the local floor surface
    Zheng, Jiacheng
    Yu, Tao
    Lei, Bo
    Chen, Chen
    INDOOR AND BUILT ENVIRONMENT, 2023, 32 (05) : 977 - 991
  • [37] A comparative experimental investigation on radiant floor heating system and stratum ventilation
    Li, Han
    Xi, Chang
    Kong, Xiangfei
    Lin, Zhang
    Wang, Lu
    SUSTAINABLE CITIES AND SOCIETY, 2020, 52
  • [38] Thermal performance of a radiant floor heating system with different heat storage materials and heating pipes
    Zhou, Guobing
    He, Jing
    APPLIED ENERGY, 2015, 138 : 648 - 660
  • [39] Evaluation and comparison of thermal comfort of convective and radiant heating terminals in office buildings
    Borong Lin
    Zhe Wang
    Hongli Sun
    Yingxin Zhu
    Qin Ouyang
    侯恩哲
    建筑节能, 2016, 44 (09) : 37 - 37
  • [40] Evaluation and comparison of thermal comfort of convective and radiant heating terminals in office buildings
    Lin, Borong
    Wang, Zhe
    Sun, Hongli
    Zhu, Yingxin
    Ouyang, Qin