Experimental evaluation of indoor thermal environment with modularity radiant heating in low energy buildings

被引:17
|
作者
Li, Zhengrong [1 ]
Zhang, Dongkai [1 ]
Li, Cui [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
基金
国家重点研发计划;
关键词
Modularity terminal; Radiant heating; Thermal performance; Thermal comfort; Energy conservation; PERFORMANCE EVALUATION; TEMPERATURE; SYSTEMS; FLOOR; COMFORT; ROOM;
D O I
10.1016/j.ijrefrig.2020.11.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
The air conditioning system in low-energy buildings should be high-efficient because of its limitation on energy consumption and requirement for thermal comfort. This study proposed a novel modularity radiant terminal which can be moved freely in the vertical direction. A series of field experiments on the optimal design scheme of modularity radiant heating terminal was conducted in a laboratory in hot summer and cold winter region of China. Indoor thermal performance with different installation position and area of modularity radiant heating panel were investigated. Results indicated that the modularity radiant heating system can maintain a comfortable indoor environment which the operative temperature can reach 21 degrees C, the vertical temperature difference below 3 degrees C and the radiation asymmetry below 4 degrees C. The design scheme of the modularity radiant heating has significant effects on indoor thermal environment, in which the installation position was a key factor. The modularity radiant panel installed in the middle of the wall and close to the floor can effectively improve the response lag of indoor thermal environment in the operation period and reduce the heat attenuation speed in the shutdown period. The response time of operative temperature at the start period can be reduced for more than 1.5 h and the thermal lag can be increased for more than 2 h at the shutdown period. Besides, the operative temperature can be increased by 1.5 K and the vertical temperature difference and the radiation asymmetry can be reduced by approximately 1 K, respectively. The optimal design of modularity radiant system can simultaneously further improve thermal comfort and realize energy consumption for low energy buildings. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:159 / 168
页数:10
相关论文
共 50 条
  • [1] Experimental research on the indoor thermal environment of the office buildings with solar energy heating in Xinjiang, China
    Xu, Xin
    Li, Jie
    Jiang, Shuguang
    Wu, Mengyun
    Dai, Jin
    Qi, Dianwei
    [J]. FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [2] Performance of Radiant Heating Systems of Low-Energy Buildings
    Sarbu, Ioan
    Mirza, Matei
    Crasmareanu, Emanuel
    [J]. WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM - WMCAUS, 2017, 245
  • [3] Improving the indoor thermal environment in lightweight buildings in winter by passive solar heating: An experimental study
    Kou, Fangcheng
    Shi, Shaohang
    Zhu, Ning
    Song, Yehao
    Zou, Yu
    Mo, Jinhan
    Wang, Xin
    [J]. INDOOR AND BUILT ENVIRONMENT, 2022, 31 (09) : 2257 - 2273
  • [4] Measurement of Indoor Thermal Environment and Analysis of Heating Energy Saving in Residential Buildings in Ulaanbaatar, Mongolia
    Batsumber, Zolsaikhan
    He, Jiang
    [J]. SUSTAINABILITY, 2023, 15 (13)
  • [5] Experimental evaluation of thermal environment built by decoupled radiant cooling system with low radiant cooling temperature
    Guo, Yanling
    Du, Ke
    Wu, Huijun
    Li, Xuemei
    Huang, Huakun
    Liu, Jia
    Huang, Gongsheng
    Xu, Xinhua
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 92
  • [6] Winter indoor thermal environment analysis of heating office buildings in Chongqing
    Liu Hong
    Li Wen-jie
    Li Bai-zhan
    Tan Mei-lan
    Li Gang
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 43 - 47
  • [7] Evaluation and comparison of thermal comfort of convective and radiant heating terminals in office buildings
    Borong Lin
    Zhe Wang
    Hongli Sun
    Yingxin Zhu
    Qin Ouyang
    侯恩哲
    [J]. 建筑节能(中英文), 2016, 44 (09) : 37 - 37
  • [8] Evaluation and comparison of thermal comfort of convective and radiant heating terminals in office buildings
    Lin, Borong
    Wang, Zhe
    Sun, Hongli
    Zhu, Yingxin
    Ouyang, Qin
    [J]. BUILDING AND ENVIRONMENT, 2016, 106 : 91 - 102
  • [9] Indoor thermal environment and heating energy saving analysis of residential buildings in Northern small towns of China
    Zhao, Jing
    Wang, Qingqin
    Zhu, Neng
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1948 - 1954
  • [10] Experimental study on energy consumption and thermal environment of radiant ceiling heating system for different types of rooms
    Liao, Wei
    Luo, Yimo
    Peng, Jinqing
    Wang, Dengjia
    Yuan, Chenzhang
    Yin, Rongxin
    Li, Nianping
    [J]. ENERGY, 2022, 244