CASE HISTORY OF ON-LINE CONDENSER TUBE CLEANING.

被引:0
|
作者
Petritsch, Joseph [1 ]
机构
[1] General Services Administration, San, Francisco, CA, USA, General Services Administration, San Francisco, CA, USA
来源
关键词
AIR CONDITIONING - Maintainability - HEAT EXCHANGERS - Condensers;
D O I
暂无
中图分类号
学科分类号
摘要
Condenser tubes with helical internal ribbing have been offered for several years. One such tube is of the multiple helix type that reportedly requires areas of only one-third to two-thirds those of smooth tubes. Thus, the incentive for chiller manufacturers to use internal helical ribbed tubes, especially with new energy conservation demands, is apparent. The ribs cause increased turbulence at the water side film boundary and increased heat transfer surface per tube. The potential problem with such internal ribs, however, is that deposits from the circulating condenser water can collect in the valleys between the helical ribs. Automatic brush cleaning system increases performance and efficiency with lowered energy and maintenance costs.
引用
收藏
页码:155 / 158
相关论文
共 50 条
  • [41] More efficiency with cleaning agents through on-line measuring of slime
    Goll, D.
    WOCHENBLATT FUR PAPIERFABRIKATION, 2007, 135 (17): : 914 - 915
  • [42] Investigation of fall-film evaporator with on-line cleaning system
    Qin, Yu-Yao
    Fu, Qin
    Xiao, Qian
    Shiyou Huagong Shebei/ Petro-Chemical Equipment, 2002, 31 (05):
  • [43] On-line cleaning of transformer oil boosts reliability, dielectric properties
    Munson, G
    Mitchell, CW
    Hachadoorian, RH
    POWER, 2003, 147 (03) : 13 - 14
  • [44] Optimisation and on-line acoustic monitoring of laser cleaning of soiled paper
    Strlic, M
    Selih, VS
    Kolar, J
    Kocar, D
    Pihlar, B
    Ostrowski, R
    Marczak, J
    Strzelec, M
    Marincek, M
    Vuorinen, T
    Johansson, LS
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2005, 81 (05): : 943 - 951
  • [45] On-line cleaning technique for mitigation of biofouling in heat exchangers: A case study of a hydroelectric power plant in Brazil
    Frota, M. N.
    Ticona, E. M.
    Neves, A. V.
    Marques, R. P.
    Braga, S. L.
    Valente, G.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 53 : 197 - 206
  • [46] LOANS AND VARIATION: THE CASE OF ON LINE/ON-LINE/ONLINE
    Sanchez Ibanez, Miguel
    DEBATE TERMINOLOGICO, 2014, (12): : 60 - 64
  • [47] Laser ultrasonic system for on-line steel tube gauging
    Monchalin, JP
    Choquet, M
    Padioleau, C
    Néron, C
    Lévesque, D
    Blouin, A
    Corbeil, C
    Talbot, R
    Bendada, A
    Lamontagne, M
    Kolarik, RV
    Jeskey, GV
    Dominik, ED
    Duly, LJ
    Samblanet, KJ
    Agger, SE
    Roush, KJ
    Mester, ML
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 22A AND 22B, 2003, 20 : 264 - 272
  • [48] Application of a design code for estimating fouling on-line in a power plant condenser cooled by seawater
    Prieto, M
    Vallina, JM
    Suárez, I
    Martín, I
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2001, 25 (05) : 329 - 336
  • [49] Comparison of power plant steam condenser heat transfer models for on-line condition monitoring
    Saari, Jussi
    Kaikko, Juha
    Vakkilainen, Esa
    Savolainen, Samuli
    APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 37 - 47
  • [50] Application of a design code for estimating fouling on-line in a power plant condenser refrigerated by seawater
    Prieto, M
    Vallina, JM
    Suárez, I
    Martín, I
    THERMAL SCIENCES 2000, 2000, : 287 - 293