Factors affecting the accuracy of TMA measurements

被引:0
|
作者
Foreman, Jonathon
Kelsey, Mark
Widmann, Georg
机构
[1] Mettler-Toledo, Inc., Columbus, OH 43240, United States
[2] Mettler-Toledo GmbH, CH-8603 Schwerzenbach, Switzerland
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This study investigates factors that cause differences between reported temperatures in thermomechanical analysis (TMA) instruments and actual sample temperatures. Observations of the melting of indium are made under several sets of conditions. These include varying the indium specimen size, altering the position of the thermal sensor, changing the heating rate, and placing pieces of indium atop and below glass and copper specimens of varying thickness. A TMA instrument with direct-contact thermal sensor and single differential thermal analysis capability yields better sample temperature measurements and allows direct examination of the effects of heat capacity. In a second set of experiments, the glass transition of polycarbonate film is measured in the tension mode using different forces and specimen lengths. The results of this study show that low material thermal conductivity and high specimen heat capacity cause the sample temperature to be lower than that of the surrounding atmosphere. Temperature gradients along the length of the furnace can intensify the temperature difference. Furthermore, stress applied to specimens in tension can lead to erroneous Tg values. Specimen and calibration procedural changes are recommended.
引用
收藏
页码:181 / 196
相关论文
共 50 条
  • [31] FACTORS AFFECTING THE ACCURACY OF FACIAL AFFECT RECOGNITION
    MUFSON, L
    NOWICKI, S
    JOURNAL OF SOCIAL PSYCHOLOGY, 1991, 131 (06): : 815 - 822
  • [32] FACTORS AFFECTING THE ACCURACY OF COAGULASE TESTS OF STAPHYLOCOCCI
    CHAPMAN, GH
    JOURNAL OF BACTERIOLOGY, 1946, 52 (01) : 151 - 151
  • [33] Factors Affecting the Accuracy of Subcounty Population Forecasts
    Rayer, Stefan
    Smith, Stanley K.
    JOURNAL OF PLANNING EDUCATION AND RESEARCH, 2010, 30 (02) : 147 - 161
  • [34] Factors Affecting the Accuracy of Automatic Signature Verification
    Kumari, Kamlesh
    Shrivastava, V. K.
    PROCEEDINGS OF THE 10TH INDIACOM - 2016 3RD INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT, 2016, : 1805 - 1808
  • [35] Factors affecting the accuracy of ventricular catheter placement
    Wan, Kai Rui
    Toy, Jennifer Ah
    Wolfe, Rory
    Danks, Andrew
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (04) : 485 - 488
  • [36] FACTORS AFFECTING THE MACHINING ACCURACY OF A CHUCKED WORKPIECE
    RAHMAN, M
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1986, 8 (01): : 34 - 40
  • [37] ELECTROMOTIVE FORCE CENTRIFUGE - FACTORS AFFECTING ACCURACY
    MACINNES, DA
    KAY, RL
    SCIENCE, 1955, 122 (3175) : 877 - 877
  • [38] FACTORS AFFECTING THE ACCURACY OF RADIO NOISE METERS
    DINGER, HE
    PAINE, HG
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1947, 35 (01): : 75 - 81
  • [39] Factors affecting accuracy of engineer's estimates
    Skitmore, Martin
    Cost Engineering (Morgantown, West Virginia), 1988, 30 (10): : 16 - 23
  • [40] SOME FACTORS AFFECTING ACCURACY OF CANCER DIAGNOSIS
    EHRLICH, D
    LISIK, M
    MODAN, B
    JOURNAL OF CHRONIC DISEASES, 1975, 28 (7-8): : 359 - 364