Factors affecting the accuracy of TMA measurements

被引:0
|
作者
Foreman, Jonathon
Kelsey, Mark
Widmann, Georg
机构
[1] Mettler-Toledo, Inc., Columbus, OH 43240, United States
[2] Mettler-Toledo GmbH, CH-8603 Schwerzenbach, Switzerland
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This study investigates factors that cause differences between reported temperatures in thermomechanical analysis (TMA) instruments and actual sample temperatures. Observations of the melting of indium are made under several sets of conditions. These include varying the indium specimen size, altering the position of the thermal sensor, changing the heating rate, and placing pieces of indium atop and below glass and copper specimens of varying thickness. A TMA instrument with direct-contact thermal sensor and single differential thermal analysis capability yields better sample temperature measurements and allows direct examination of the effects of heat capacity. In a second set of experiments, the glass transition of polycarbonate film is measured in the tension mode using different forces and specimen lengths. The results of this study show that low material thermal conductivity and high specimen heat capacity cause the sample temperature to be lower than that of the surrounding atmosphere. Temperature gradients along the length of the furnace can intensify the temperature difference. Furthermore, stress applied to specimens in tension can lead to erroneous Tg values. Specimen and calibration procedural changes are recommended.
引用
收藏
页码:181 / 196
相关论文
共 50 条
  • [21] FACTORS AFFECTING VISUAL INSPECTION ACCURACY
    MEGAW, ED
    APPLIED ERGONOMICS, 1979, 10 (01) : 27 - 32
  • [22] SITUATIONAL FACTORS AFFECTING FORECAST ACCURACY
    SCHNAARS, SP
    JOURNAL OF MARKETING RESEARCH, 1984, 21 (03) : 290 - 297
  • [23] Factors Affecting Insulin Dosing Accuracy
    Virdi, Naunihal S.
    Mahoney, John J.
    DIABETES, 2012, 61 : A589 - A589
  • [24] Factors Affecting Accuracy in Proton Therapy
    Cheng, C.
    Zhao, L.
    Zhao, Q.
    Moskvin, V.
    Buchsbaum, J.
    Das, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3771 - 3771
  • [25] Factors affecting SMD placement accuracy
    Amistar, San Marcos, United States
    Electron Packag Prod, 1 (5pp):
  • [26] Some factors affecting diagnostic accuracy
    Atwell, R
    Heath, T
    AUSTRALIAN VETERINARY PRACTITIONER, 2006, 36 (01): : 23 - 28
  • [27] Some factors affecting diagnostic accuracy
    Atwell, R
    Heath, T
    AUSTRALIAN VETERINARY PRACTITIONER, 2001, 31 (01): : 18 - +
  • [28] FACTORS AFFECTING THE ACCURACY OF PRICE FORECASTS
    Fox, Karl A.
    JOURNAL OF FARM ECONOMICS, 1953, 35 (03): : 323 - 340
  • [29] Factors affecting the accuracy of pressure measurements in vascular stenoses from phase-contrast MRI
    Nasiraei-Moghaddam, A
    Behrens, G
    Fatouraee, N
    Agarwal, R
    Choi, ET
    Amini, AA
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) : 300 - 309
  • [30] A Systematic Review of the Factors Affecting Accuracy of SUV Measurements (vol 195, pg 310, 2010)
    Chandarana, Hersh
    Lee, Carol H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) : 1043 - 1043