Factors affecting the accuracy of TMA measurements

被引:0
|
作者
Foreman, Jonathon
Kelsey, Mark
Widmann, Georg
机构
[1] Mettler-Toledo, Inc., Columbus, OH 43240, United States
[2] Mettler-Toledo GmbH, CH-8603 Schwerzenbach, Switzerland
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This study investigates factors that cause differences between reported temperatures in thermomechanical analysis (TMA) instruments and actual sample temperatures. Observations of the melting of indium are made under several sets of conditions. These include varying the indium specimen size, altering the position of the thermal sensor, changing the heating rate, and placing pieces of indium atop and below glass and copper specimens of varying thickness. A TMA instrument with direct-contact thermal sensor and single differential thermal analysis capability yields better sample temperature measurements and allows direct examination of the effects of heat capacity. In a second set of experiments, the glass transition of polycarbonate film is measured in the tension mode using different forces and specimen lengths. The results of this study show that low material thermal conductivity and high specimen heat capacity cause the sample temperature to be lower than that of the surrounding atmosphere. Temperature gradients along the length of the furnace can intensify the temperature difference. Furthermore, stress applied to specimens in tension can lead to erroneous Tg values. Specimen and calibration procedural changes are recommended.
引用
收藏
页码:181 / 196
相关论文
共 50 条
  • [1] Factors affecting the accuracy of TMA measurements
    Foreman, J
    Kelsey, M
    Widmann, G
    LIMITATIONS OF TEST METHODS FOR PLASTICS, 2000, 1369 : 181 - 196
  • [2] Diagnostic Accuracy of FibroScan and Factors Affecting Measurements
    Oeda, Satoshi
    Tanaka, Kenichi
    Oshima, Ayaka
    Matsumoto, Yasue
    Sueoka, Eisaburo
    Takahashi, Hirokazu
    DIAGNOSTICS, 2020, 10 (11)
  • [3] Factors Affecting the Accuracy of Vitamin D Measurements
    Aydin, Fevzi Nuri
    Aydin, Ibrahim
    Agilli, Mehmet
    CLINICAL MEDICINE & RESEARCH, 2014, 12 (1-2) : 4 - 4
  • [4] FACTORS AFFECTING ACCURACY OF AVERAGE DUST CONCENTRATION MEASUREMENTS
    LECLARE, PC
    BRESLIN, AJ
    ONG, LDY
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1968, 29 (02): : 87 - &
  • [5] FACTORS AFFECTING ACCURACY OF AVERAGE DUST CONCENTRATION MEASUREMENTS
    LECLARE, PC
    BRESLIN, AJ
    ONG, LDY
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1969, 30 (04): : 386 - &
  • [6] A Systematic Review of the Factors Affecting Accuracy of SUV Measurements
    Adams, Michael C.
    Turkington, Timothy G.
    Wilson, Joshua M.
    Wong, Terence Z.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) : 310 - 320
  • [7] Factors affecting the accuracy of structure factor measurements in TiAl
    Swaminathan, S
    Wiezorek, JMK
    Zaluzec, NJ
    Jones, IP
    Maher, DM
    Fraser, HL
    ELECTRON MICROSCOPY AND ANALYSIS 1995, 1995, 147 : 133 - 136
  • [8] Factors affecting the accuracy of SHOWEX HF radar wave measurements
    Wyatt, LR
    Liakhovetski, G
    Graber, HC
    Haus, BK
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2005, 22 (07) : 847 - 859
  • [9] DISCUSSION OF FACTORS AFFECTING ABSOLUTE ACCURACY OF MOSSBAUER F MEASUREMENTS
    HOUSLEY, RM
    NUCLEAR INSTRUMENTS & METHODS, 1965, 35 (01): : 77 - &
  • [10] Some factors affecting the accuracy and variability of measurements of the height of ponies
    Lamas, L. P.
    Giovagnoli, G.
    Heath, M. F.
    Jeffcott, L. B.
    VETERINARY RECORD, 2007, 160 (20) : 691 - 694