Study and optimization of the influence of the water tank temperature on the performance of a solar assisted multi-source heat pump drying system

被引:0
|
作者
Hou, Feng [1 ]
Lu, Yan [1 ]
He, Ting [1 ]
Sun, Hongchuang [1 ]
Li, Yawei [1 ]
Yuan, Pei [1 ]
机构
[1] Zhengzhou Univ Light Ind, Coll New Energy, Zhengzhou 450002, Henan, Peoples R China
关键词
Solar energy; Heat pump; Drying system; Control logic; ENERGY; DRYER;
D O I
10.1016/j.applthermaleng.2024.124922
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar assisted air source heat pump drying (SASHPD) system has been widely studied due to its excellent energy saving and high dried quality of product. To improve system performance, the control logic of a solar assisted multi-source heat pump drying (SMSHPD) system was investigated, and the simulation model and the experimental platform were established in this paper. The seasonal operating characteristics of the air source heat pump drying (ASHPD), the SASHPD and the SMSHPD modes were studied. The energy consumption, coefficient of performance (COP) and specific moisture extraction rate (SMER) of the three drying systems were calculated and analyzed. Additionally, the water tank temperature were also measured to determine the seasonal control logic of the drying system. It was found that compared to the ASHPD system, in summer, the energy consumption of the SASHPD system was reduced by 33.06 %, and COP and SMER was increased by 49.4 % and 49.38 %, respectively. Moreover, because of the high ambient temperature and water tank temperature, the experimental results indicated that only the SASHPD control logic should be implemented in summer. The maximum error of the simulation results was 9.1 % and the accuracy of the simulation model was confirmed. In autumn, the lower water tank temperature after drying illustrated that the solar energy can be more fully utilized, which explained why the performance of the SMSHPD mode was increased by 6.5 % compared to the SASHPD mode. Consequently, it is necessary to implement the SMSHPD control logic in autumn. Moreover, the operating temperature of the water source heat pump drying mode in autumn was optimized and the optimal temperature range was 28-54 degrees C. The average COP in one week after optimization was 6.21 % higher than that of the original operating temperature. Based on the validated simulation model, the optimal operating temperatures in spring and winter were also calculated and the control logic of the SMSHPD system operating in the four seasons were all obtained. This paper has important guiding significance for the reasonable choice of the control logic of a solar combined air source heat pump drying system.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Performance optimization and benefit analyses of a photovoltaic loop heat pipe/solar assisted heat pump water heating system
    Li, Hong
    Sun, Yue
    RENEWABLE ENERGY, 2019, 134 : 1240 - 1247
  • [42] Theoretical and Experimental Study of Solar Assisted Heat Pump System for Grain Storage Drying
    Li, Haifeng
    Dai, Yanjun
    Li, Yong
    Li, Zongliang
    Lu, Xianli
    Gao, Sufen
    Wei, Lei
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1777 - 1784
  • [43] Investigation on the thermal performance and economy of a solar assisted air source heat pump domestic hot water system
    Ma, Shuo
    Lu, Shilei
    Ma, Dandan
    Li, Chen
    Liu, Chen
    Wu, Liwen
    Chen, Mo
    Xu, Chang
    Ma, Hongting
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [44] Simulative study on solar-assisted air source heat pump system
    Wang, Qiang
    Liu, Fengzhen
    Hou, Lijun
    Gao, Jianhua
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 2141 - +
  • [45] Theoretical Study of a Multilevel Heat Pump for Multi-Source Heating
    Badran, Bassam E.
    Mota-Babiloni, Adrian
    Ghanbarpour, Morteza
    Khodabandeh, Rahmatollah
    6TH IIR CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR2021), 2021, : 243 - 250
  • [46] Operational performance study on a photovoltaic loop heat pipe/solar assisted heat pump water heating system
    Li, Hong
    Sun, Yue
    ENERGY AND BUILDINGS, 2018, 158 : 861 - 872
  • [47] Performance, energy and exergy analysis of solar-assisted heat pump drying system with heat recovery: A comprehensive experimental study
    Yao, Muchi
    Li, Ming
    Zhang, Yi
    Wang, Yunfeng
    Li, Guoliang
    Zhang, Ying
    Deng, Zhihan
    Xing, Tianyu
    Zhu, Yinlong
    RENEWABLE ENERGY, 2025, 244
  • [48] Exergy analysis and experiment research of solar assisted water source heat pump system
    Gong, Guangcai
    Wang, Lijun
    Su, Huan
    Gong, G. (gcgong@hnu.edu.cn), 1600, Science Press (34): : 1051 - 1056
  • [49] Multi-source hydronic heat pump application study and analysis
    Meckler, Milton
    Energy Engineering: Journal of the Association of Energy Engineering, 1988, 85 (06): : 32 - 48
  • [50] PERFORMANCE ANALYSIS OF A HEAT-PUMP ASSISTED DRYING SYSTEM
    ALMEIDA, MSV
    GOUVEIA, MC
    ZDEBSKY, SR
    PARISE, JAR
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1990, 14 (04) : 397 - 406