Study and optimization of the influence of the water tank temperature on the performance of a solar assisted multi-source heat pump drying system

被引:0
|
作者
Hou, Feng [1 ]
Lu, Yan [1 ]
He, Ting [1 ]
Sun, Hongchuang [1 ]
Li, Yawei [1 ]
Yuan, Pei [1 ]
机构
[1] Zhengzhou Univ Light Ind, Coll New Energy, Zhengzhou 450002, Henan, Peoples R China
关键词
Solar energy; Heat pump; Drying system; Control logic; ENERGY; DRYER;
D O I
10.1016/j.applthermaleng.2024.124922
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar assisted air source heat pump drying (SASHPD) system has been widely studied due to its excellent energy saving and high dried quality of product. To improve system performance, the control logic of a solar assisted multi-source heat pump drying (SMSHPD) system was investigated, and the simulation model and the experimental platform were established in this paper. The seasonal operating characteristics of the air source heat pump drying (ASHPD), the SASHPD and the SMSHPD modes were studied. The energy consumption, coefficient of performance (COP) and specific moisture extraction rate (SMER) of the three drying systems were calculated and analyzed. Additionally, the water tank temperature were also measured to determine the seasonal control logic of the drying system. It was found that compared to the ASHPD system, in summer, the energy consumption of the SASHPD system was reduced by 33.06 %, and COP and SMER was increased by 49.4 % and 49.38 %, respectively. Moreover, because of the high ambient temperature and water tank temperature, the experimental results indicated that only the SASHPD control logic should be implemented in summer. The maximum error of the simulation results was 9.1 % and the accuracy of the simulation model was confirmed. In autumn, the lower water tank temperature after drying illustrated that the solar energy can be more fully utilized, which explained why the performance of the SMSHPD mode was increased by 6.5 % compared to the SASHPD mode. Consequently, it is necessary to implement the SMSHPD control logic in autumn. Moreover, the operating temperature of the water source heat pump drying mode in autumn was optimized and the optimal temperature range was 28-54 degrees C. The average COP in one week after optimization was 6.21 % higher than that of the original operating temperature. Based on the validated simulation model, the optimal operating temperatures in spring and winter were also calculated and the control logic of the SMSHPD system operating in the four seasons were all obtained. This paper has important guiding significance for the reasonable choice of the control logic of a solar combined air source heat pump drying system.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Performance of solar energy automatic control system assisted dual water tank with phase change materials and heat pump
    Qu, Shilin
    Yang, Lixiang
    Peng, Li
    Hu, Jiaguo
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2014, 47 (01): : 42 - 46
  • [32] Simultaneous Optimization of Pump Configuration and Pipe Network in Multi-source Water Injection System
    Yang, Jianjun
    Wu, Tangfu
    Liu, Zhihao
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MECHATRONICS AND INDUSTRIAL INFORMATICS, 2015, 31 : 103 - 106
  • [33] Simultaneous Optimization of Pump Configuration and Operation Parameters in Multi-source Water Injection System
    Yang, Jianjun
    Li, Qingtang
    Zhang, Zhiyuan
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS, 2015, 21 : 63 - 67
  • [34] Performance investigation of a novel low-carbon solar-assisted multi-source heat pump heating system demonstrated in a public building in Hull
    Li, Yunhai
    Li, Zhaomeng
    Song, Zhiying
    Fan, Yi
    Zhao, Xudong
    Li, Jing
    ENERGY CONVERSION AND MANAGEMENT, 2024, 300
  • [35] PERFORMANCE ANALYSIS AND COST OPTIMIZATION OF A SOLAR-ASSISTED HEAT PUMP SYSTEM
    MACARTHUR, JW
    PALM, WJ
    LESSMANN, RC
    SOLAR ENERGY, 1978, 21 (01) : 1 - 9
  • [36] An economic optimization of evaporator and air collector area in a solar assisted heat pump drying system
    Rahman, S. M. A.
    Saidur, R.
    Hawlader, M. N. A.
    ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 377 - 384
  • [37] Performance analysis of a secondary heat recovery solar-assisted heat pump drying system for mango
    Wang, Yunfeng
    Li, Ming
    Qiu, Yu
    Yu, Qiongfen
    Luo, Xi
    Li, Guoliang
    Ma, Xun
    ENERGY EXPLORATION & EXPLOITATION, 2019, 37 (04) : 1377 - 1387
  • [38] Performance simulation of multiple heat source solar heat pump water heater system
    Yang, Lei
    Zhang, Xiaosong
    Huagong Xuebao/CIESC Journal, 2009, 60 (09): : 2292 - 2298
  • [39] Integrated optimization study of hot water supply system with multi-heat-source for the public bath based on PVT heat pump and water source heat pump
    Mi, Peiyuan
    Ma, Liangdong
    Zhang, Jili
    APPLIED THERMAL ENGINEERING, 2020, 176
  • [40] Life Cycle Cost Optimization of a Solar Assisted Ground Source Heat Pump System
    Weeratunge, Hansani
    de Hoog, Julian
    Dunstall, Simon
    Narsilio, Guillermo
    Halgamuge, Saman
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,