Study and optimization of the influence of the water tank temperature on the performance of a solar assisted multi-source heat pump drying system

被引:0
|
作者
Hou, Feng [1 ]
Lu, Yan [1 ]
He, Ting [1 ]
Sun, Hongchuang [1 ]
Li, Yawei [1 ]
Yuan, Pei [1 ]
机构
[1] Zhengzhou Univ Light Ind, Coll New Energy, Zhengzhou 450002, Henan, Peoples R China
关键词
Solar energy; Heat pump; Drying system; Control logic; ENERGY; DRYER;
D O I
10.1016/j.applthermaleng.2024.124922
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar assisted air source heat pump drying (SASHPD) system has been widely studied due to its excellent energy saving and high dried quality of product. To improve system performance, the control logic of a solar assisted multi-source heat pump drying (SMSHPD) system was investigated, and the simulation model and the experimental platform were established in this paper. The seasonal operating characteristics of the air source heat pump drying (ASHPD), the SASHPD and the SMSHPD modes were studied. The energy consumption, coefficient of performance (COP) and specific moisture extraction rate (SMER) of the three drying systems were calculated and analyzed. Additionally, the water tank temperature were also measured to determine the seasonal control logic of the drying system. It was found that compared to the ASHPD system, in summer, the energy consumption of the SASHPD system was reduced by 33.06 %, and COP and SMER was increased by 49.4 % and 49.38 %, respectively. Moreover, because of the high ambient temperature and water tank temperature, the experimental results indicated that only the SASHPD control logic should be implemented in summer. The maximum error of the simulation results was 9.1 % and the accuracy of the simulation model was confirmed. In autumn, the lower water tank temperature after drying illustrated that the solar energy can be more fully utilized, which explained why the performance of the SMSHPD mode was increased by 6.5 % compared to the SASHPD mode. Consequently, it is necessary to implement the SMSHPD control logic in autumn. Moreover, the operating temperature of the water source heat pump drying mode in autumn was optimized and the optimal temperature range was 28-54 degrees C. The average COP in one week after optimization was 6.21 % higher than that of the original operating temperature. Based on the validated simulation model, the optimal operating temperatures in spring and winter were also calculated and the control logic of the SMSHPD system operating in the four seasons were all obtained. This paper has important guiding significance for the reasonable choice of the control logic of a solar combined air source heat pump drying system.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Assessment of a solar assisted air source and a solar assisted water source heat pump system in a Canadian household
    Kegel, Martin
    Tamasauskas, Justin
    Sunye, Roberto
    Langlois, Antoine
    1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 : 654 - 663
  • [22] Performance study on heat pump sub-system in parallel of solar assisted heat pump water heater
    Feng, Shiyu
    Gao, Xiufeng
    Hu, Wei
    Li, Yun
    Gu, Zhaolin
    Wang, Huiyu
    Luo, Cong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (02): : 125 - 129
  • [23] Investigation of a solar assisted heat pump wheat drying system with underground thermal energy storage tank
    Ismaeel, Hatem Hasan
    Yumrutas, Recep
    SOLAR ENERGY, 2020, 199 : 538 - 551
  • [24] A Study on the Effect of the Weather Conditions on the Performance of the Solar Assisted Heat Pump Drying System for Red Chili
    Le Minh Nhut
    Huynh Thi Thu Hien
    Park, Youn Cheol
    Bui Quang Huy
    PROCEEDINGS OF 2019 INTERNATIONAL CONFERENCE ON SYSTEM SCIENCE AND ENGINEERING (ICSSE), 2019, : 677 - 680
  • [25] THERMAL PERFORMANCE ANALYSIS AND OPTIMIZATION OF SOLAR ASSISTED HEAT PUMP WATER HEATER
    Kokila, R. N.
    Rajakumar, S.
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 2416 - +
  • [26] Performance Predication of Solar Assisted Chemical Heat Pump Drying System in Tropical Region
    Ibrahim, M.
    Sopian, K.
    Daud, W. R. W.
    Yahya, M.
    Alghoul, M. A.
    Zaharim, A.
    RES 08: PROCEEDINGS OF THE 2ND WSEAS/IASME INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY SOURCES, 2008, : 122 - 126
  • [27] Experimental Study of the Performance of Air Source Heat Pump Systems Assisted by Low-Temperature Solar-Heated Water
    Wu, Jinshun
    Chen, Chao
    Pan, Song
    Wei, Jun
    Pan, Tianquan
    Wei, Yixuan
    Wang, Yunmo
    Wang, Xinru
    Su, Jiale
    ADVANCES IN MECHANICAL ENGINEERING, 2013,
  • [28] A solar assisted heat pump drying system for grain in-store drying
    Li H.
    Dai Y.
    Dai J.
    Wang X.
    Wei L.
    Frontiers of Energy and Power Engineering in China, 2010, 4 (3): : 386 - 391
  • [29] A heat pump coupled with photovoltaic thermal hybrid solar collectors: A case study of a multi-source energy system
    Emmi, Giuseppe
    Zarrella, Angelo
    De Carli, Michele
    ENERGY CONVERSION AND MANAGEMENT, 2017, 151 : 386 - 399
  • [30] Influence analysis and experimental study of heat storage water tank on performance characteristics of solar energy-water source heat
    Qu, Shilin
    Sun, Zhifeng
    Ji, Yubao
    Chen, Caixia
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2012, 33 (08): : 1405 - 1410