Experimental study on effect of energy transition of base-isolation with energy transducer system

被引:0
|
作者
Cheng, Shu-Liang [1 ]
Wang, Huan-Ding [1 ]
Sun, Zuo-Yu [2 ]
机构
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
[2] School of Civil Engineering, Guangzhou University, Guangzhou 510405, China
来源
Gongcheng Lixue/Engineering Mechanics | 2006年 / 23卷 / 11期
关键词
Energy dissipation - Hydraulics - Seismic waves - Structural analysis - Transducers - Vibration control;
D O I
暂无
中图分类号
学科分类号
摘要
The base-isolation with energy transducer (BIET) system is the base-isolation structure equipped with energy transducer on isolation storey, which can transform part of the seismic energy into hydraulic energy and store it. Shaking table tests of a 5-floor steel frame model (BIET system) are conducted to study the effects of energy transition, the control of the BIET system, and the performance of the transducer. The study lays the foundation for the application of the system. The results of the tests show that the energy transducer performs well in energy transition with merits such as reliable output of force and stable energy dissipation, and the BIET system can transform 50%-80% of the seismic energy into hydraulic energy on the premise that the structural control function is similar to that in the lead rubber bearing isolation system.
引用
收藏
页码:38 / 44
相关论文
共 50 条
  • [41] Adaptive base isolation system for the control of seismic energy flow into buildings
    Sener, M
    Utku, S
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1998, 9 (02) : 104 - 115
  • [42] Adaptive base isolation system for the control of seismic energy flow into buildings
    Adim Construction Ltd Co, Istanbul, Turkey
    J Intell Mater Syst Struct, 2 (104-115):
  • [43] Hybrid optimization design approach of asymmetric base-isolation coupling system for twin buildings
    Park, Wonsuk
    Ok, Seung-Yong
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2021, 40 (04) : 1993 - 2013
  • [44] Fuzzy control of base-isolation system using multi-objective genetic algorithm
    Kim, Hyun-Su
    Roschke, Paul N.
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2006, 21 (06) : 436 - 449
  • [45] Sliding mode control of base-isolation system using semi-active hydraulic damper
    Nagashima I.
    Shinozaki Y.
    Maseki R.
    Sanui Y.
    Kitagawa Y.
    Journal of Structural and Construction Engineering, 2010, 75 (649): : 511 - 519
  • [46] VERIFICATION OF RESPONSE REDUCTION EFFECT OF SEMI-ACTIVE CONTROL FOR BASE-ISOLATION SYSTEM USING E-DEFENSE
    Fujitani, Hideo
    Sato, Eiji
    Mukai, Yoichi
    Kishida, Akiko
    Itahara, Keiju
    Hashimoto, Mana
    Johnson, Erik
    Christenson, Richard
    Ito, Mai
    Journal of Structural and Construction Engineering, 89 (825): : 1202 - 1213
  • [47] Experimental study for wind power - Hydrogen energy system with energy capacitor system
    Nitta, M
    Hashimoto, S
    Sekiguchi, N
    Kouchi, Y
    Yachi, T
    Tani, T
    INTELEC'03: POWERING THE BROADBAND NETWORK, PROCEEDINGS, 2003, : 451 - 456
  • [48] Effects of nonlinear modelling of the base-isolation system on the seismic analysis of r.c. buildings
    Mazza, Fabio
    Labernarda, Rodolfo
    XIV INTERNATIONAL CONFERENCE ON BUILDING PATHOLOGY AND CONSTRUCTIONS REPAIR, 2018, 11 : 226 - 233
  • [49] Expansion of the investor base for the energy transition
    McInerney, Celine
    Bunn, Derek W.
    ENERGY POLICY, 2019, 129 : 1240 - 1244
  • [50] Study on the Total Life-cycle Cost Evaluation Method of the Base-isolation Structure
    Sun Hong-ling
    Sun Peng
    CIVIL ENGINEERING IN CHINA - CURRENT PRACTICE AND RESEARCH REPORT, 2010, : 1153 - 1157