Experimental study on effect of energy transition of base-isolation with energy transducer system

被引:0
|
作者
Cheng, Shu-Liang [1 ]
Wang, Huan-Ding [1 ]
Sun, Zuo-Yu [2 ]
机构
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
[2] School of Civil Engineering, Guangzhou University, Guangzhou 510405, China
来源
Gongcheng Lixue/Engineering Mechanics | 2006年 / 23卷 / 11期
关键词
Energy dissipation - Hydraulics - Seismic waves - Structural analysis - Transducers - Vibration control;
D O I
暂无
中图分类号
学科分类号
摘要
The base-isolation with energy transducer (BIET) system is the base-isolation structure equipped with energy transducer on isolation storey, which can transform part of the seismic energy into hydraulic energy and store it. Shaking table tests of a 5-floor steel frame model (BIET system) are conducted to study the effects of energy transition, the control of the BIET system, and the performance of the transducer. The study lays the foundation for the application of the system. The results of the tests show that the energy transducer performs well in energy transition with merits such as reliable output of force and stable energy dissipation, and the BIET system can transform 50%-80% of the seismic energy into hydraulic energy on the premise that the structural control function is similar to that in the lead rubber bearing isolation system.
引用
收藏
页码:38 / 44
相关论文
共 50 条
  • [31] Comparative Study of Smart Base-Isolation Using Fuzzy Control and Neural Network
    Lakhani, Megha T.
    Soni, Devesh P.
    PLASTICITY AND IMPACT MECHANICS, 2017, 173 : 1825 - 1832
  • [32] DESIGN EXPERIENCE OF A BASE-ISOLATION SYSTEM APPLIED TO A COMPUTER-CENTER BUILDING
    HASEBE, A
    KOJIMA, H
    TAMURA, K
    NUCLEAR ENGINEERING AND DESIGN, 1991, 127 (03) : 339 - 349
  • [33] Seismic Performance Analysis of A Smart Base-isolation System Considering Dynamics of MR Elastomers
    Jung, Hyung-Jo
    Eem, Seung-Hyun
    Jang, Dong-Doo
    Koo, Jeong-Hoi
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2011, 22 (13) : 1439 - 1450
  • [34] FINITE-ELEMENT ANALYSIS OF LAMINATED RUBBER BEARING USED IN BASE-ISOLATION SYSTEM
    TAKAYAMA, M
    TADA, H
    TANAKA, R
    RUBBER CHEMISTRY AND TECHNOLOGY, 1992, 65 (01): : 46 - 62
  • [35] Semi-active control of base isolation with energy transition control device
    Cheng Shuliang
    Xin Yajun
    Wang Yanwu
    CEIS 2011, 2011, 15
  • [36] Passive combined control of the seismic response of structures by use of base-isolation and TMD system
    Zhu, HP
    Tang, JX
    Kuang, JS
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 567 - 574
  • [37] Base isolation versus energy dissipation
    Olariu, I
    Olariu, F
    Sarbu, D
    STRUCTURAL DYNAMICS, VOLS 1 AND 2, 1999, : 543 - 548
  • [38] INTERACTIVE BASE-ISOLATION FOUNDATION SYSTEM .1. FINITE-ELEMENT FORMULATION
    KI, JA
    GOULD, PL
    JOURNAL OF ENGINEERING MECHANICS, 1992, 118 (10) : 2048 - 2058
  • [39] PASSIVE ANTISEISMIC PROTECTIONS OF MULTISTORY BUILDING BY CONTROLLED BUCKLING OF A STEEL BASE-ISOLATION SYSTEM
    CAROTTI, A
    DEMIRANDA, FG
    MECHANICS RESEARCH COMMUNICATIONS, 1990, 17 (03) : 149 - 155
  • [40] PERFORMANCE OF A HIGH DAMPING RUBBER BEARING BASE-ISOLATION SYSTEM FOR A SHEAR BEAM STRUCTURE
    CHEN, Y
    AHMADI, G
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1994, 23 (07): : 729 - 744