Experimental study on effect of energy transition of base-isolation with energy transducer system

被引:0
|
作者
Cheng, Shu-Liang [1 ]
Wang, Huan-Ding [1 ]
Sun, Zuo-Yu [2 ]
机构
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
[2] School of Civil Engineering, Guangzhou University, Guangzhou 510405, China
来源
Gongcheng Lixue/Engineering Mechanics | 2006年 / 23卷 / 11期
关键词
Energy dissipation - Hydraulics - Seismic waves - Structural analysis - Transducers - Vibration control;
D O I
暂无
中图分类号
学科分类号
摘要
The base-isolation with energy transducer (BIET) system is the base-isolation structure equipped with energy transducer on isolation storey, which can transform part of the seismic energy into hydraulic energy and store it. Shaking table tests of a 5-floor steel frame model (BIET system) are conducted to study the effects of energy transition, the control of the BIET system, and the performance of the transducer. The study lays the foundation for the application of the system. The results of the tests show that the energy transducer performs well in energy transition with merits such as reliable output of force and stable energy dissipation, and the BIET system can transform 50%-80% of the seismic energy into hydraulic energy on the premise that the structural control function is similar to that in the lead rubber bearing isolation system.
引用
收藏
页码:38 / 44
相关论文
共 50 条
  • [22] Suggestion of the magnet solidification fluid (MSF), and application to a base-isolation system
    Sugimoto, N
    Kiyota, T
    Sasaki, T
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2005, 19 (7-9): : 1499 - 1505
  • [23] Sliding mode control of buildings with base-isolation hybrid protective system
    Zhao, Bin
    Lu, Xilin
    Wu, Minzhe
    Mei, Zhanxin
    Earthquake Engineering and Structural Dynamics, 2000, 29 (03) : 315 - 326
  • [24] DYNAMIC ANALYSIS OF A SMART BASE-ISOLATION SYSTEM BASED ON MR ELASTOMERS
    Jung, Hyung-Jo
    Park, Jeong-Su
    Koo, Jeong-Hoi
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2010, VOL 2, 2010, : 413 - 418
  • [25] Sliding mode control of buildings with base-isolation hybrid protective system
    Zhao, B
    Lu, XL
    Wu, MZ
    Mei, ZX
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (03): : 315 - 326
  • [26] Effect of the section geometry of saucepan base on the energy consumption: an experimental study
    Tahir Ayata
    Yılmaz Yücel
    Heat and Mass Transfer, 2017, 53 : 1155 - 1161
  • [27] Effect of the section geometry of saucepan base on the energy consumption: an experimental study
    Ayata, Tahir
    Yucel, Yilmaz
    HEAT AND MASS TRANSFER, 2017, 53 (04) : 1155 - 1161
  • [28] Low-Cost Base-Isolation System for Seismic Protection of Rural Buildings
    Nanda, Radhikesh P.
    Shrikhande, Manish
    Agarwal, Pankaj
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2016, 21 (01)
  • [29] ANALYSIS OF P-Δ EFFECTS IN CANTILEVER BASEMENT COLUMN OF THE BASE-ISOLATION SYSTEM
    Li Hui
    Zhang Huaying
    Zhang Xin
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON INSPECTION APPRAISAL REPAIRS AND MAINTENANCE OF STRUCTURES, VOLS 1 AND 2, 2010, : 569 - +
  • [30] Three-dimensional base-isolation system using thick rubber bearings
    Wang, T.
    Wang, F.
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2012, 2012, 8341