Physical design of high mass resolution spectrometer for ISOL

被引:0
|
作者
China Institute of Atomic Energy, P.O. Box 275-62, Beijing 102413, China [1 ]
机构
来源
Yuanzineng Kexue Jishu | 2006年 / 2卷 / 133-138期
关键词
Acceleration - Design - Dispersion (waves) - Ion beams - Isotopes - Optical resolving power - Radioactivity - Separators;
D O I
暂无
中图分类号
学科分类号
摘要
High mass resolution spectrometer for isotope separator on line (ISOL) in Beijing radioactive ion-beam facilities (BRIF) project requires mass resolving power of 20000. A bi-energy system with big and small dipoles is used to reduce energy dispersion which is too large to get mass resolving power. When the width of beam with a Gaussian distribution is 0.06 mm and 10 mrad, resolving power of this spectrometer is 33400. After consideration of 0.002% energy spread introduced by acceleration, the final resolving power of this spectrometer reaches 20000.
引用
收藏
相关论文
共 50 条
  • [31] HIGH-RESOLUTION TIME-OF-FLIGHT MASS-SPECTROMETER
    BERGMANN, T
    MARTIN, TP
    SCHABER, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (04): : 792 - 793
  • [32] High-resolution mass spectrometer for liquid metal ion sources
    Wortmann, Martin
    Ludwig, Arne
    Meijer, Jan
    Reuter, Dirk
    Wieck, Andreas D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (09):
  • [33] A high-resolution mass spectrometer to measure atmospheric ion composition
    Junninen, H.
    Ehn, M.
    Petaja, T.
    Luosujarvi, L.
    Kotiaho, T.
    Kostiainen, R.
    Rohner, U.
    Gonin, M.
    Fuhrer, K.
    Kulmala, M.
    Worsnop, D. R.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2010, 3 (04) : 1039 - 1053
  • [34] ON-LINE HIGH RESOLUTION MASS SPECTROMETER DATA ACQUISITION SYSTEM
    HERRMANN, RA
    MCNEILL, JP
    APPLIED SPECTROSCOPY, 1968, 22 (03) : 240 - &
  • [35] Design and performance of a high resolution electrospray ion source for a magnetic sector mass spectrometer with a heated capillary inlet
    Jiang, LF
    Moini, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (12) : 1256 - 1261
  • [36] Miniature, high-resolution, quadrupole mass-spectrometer array
    Orient, OJ
    Chutjian, A
    Garkanian, V
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (03): : 1393 - 1397
  • [37] HIGH-RESOLUTION ON A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    SCHWARTZ, JC
    SYKA, JEP
    JARDINE, I
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) : 198 - 204
  • [39] Design and test of a lens system for a high energy and high resolution electron spectrometer
    Offi, F
    Fondacaro, A
    Paolicelli, G
    De Luisa, A
    Stefani, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2): : 454 - 466
  • [40] Design and implementation of a high-resolution, high-efficiency optical spectrometer
    Utter, SB
    López-Urrutia, JRC
    Beiersdorfer, P
    Träbert, E
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (11): : 3737 - 3741