High mass resolution spectrometer for isotope separator on line (ISOL) in Beijing radioactive ion-beam facilities (BRIF) project requires mass resolving power of 20000. A bi-energy system with big and small dipoles is used to reduce energy dispersion which is too large to get mass resolving power. When the width of beam with a Gaussian distribution is 0.06 mm and 10 mrad, resolving power of this spectrometer is 33400. After consideration of 0.002% energy spread introduced by acceleration, the final resolving power of this spectrometer reaches 20000.