Physical design of high mass resolution spectrometer for ISOL

被引:0
|
作者
China Institute of Atomic Energy, P.O. Box 275-62, Beijing 102413, China [1 ]
机构
来源
Yuanzineng Kexue Jishu | 2006年 / 2卷 / 133-138期
关键词
Acceleration - Design - Dispersion (waves) - Ion beams - Isotopes - Optical resolving power - Radioactivity - Separators;
D O I
暂无
中图分类号
学科分类号
摘要
High mass resolution spectrometer for isotope separator on line (ISOL) in Beijing radioactive ion-beam facilities (BRIF) project requires mass resolving power of 20000. A bi-energy system with big and small dipoles is used to reduce energy dispersion which is too large to get mass resolving power. When the width of beam with a Gaussian distribution is 0.06 mm and 10 mrad, resolving power of this spectrometer is 33400. After consideration of 0.002% energy spread introduced by acceleration, the final resolving power of this spectrometer reaches 20000.
引用
收藏
相关论文
共 50 条
  • [21] HIGH-RESOLUTION MASS-SPECTROMETER FOR PROTEIN CHEMISTRY
    LI, YZ
    HUNTER, RL
    MCIVER, RT
    NATURE, 1994, 370 (6488) : 393 - 395
  • [22] DESIGN OF A HIGH-RESOLUTION MASS SPECTROMETER FOR STUDYING THE PHOTODISSOCIATION OF ORGANIC IONS IN THE GAS PHASE.
    Harris, F.M.
    Mukhtar, E.S.
    Griffiths, I.W.
    Beynon, J.H.
    Proceedings of The Royal Society of London, Series A: Mathematical and Physical Sciences, 1981, 374 (1759) : 461 - 473
  • [23] Optical design for a breadboard high resolution spectrometer for SIRTF/IRS
    Brown, RJ
    Houck, JR
    VanCleve, J
    CURRENT DEVELOPMENTS IN OPTICAL DESIGN AND ENGINEERING VI, 1996, 2863 : 222 - 226
  • [24] DESIGN OF A HIGH-RESOLUTION FOURIER-TRANSFORM SPECTROMETER
    PALMER, BA
    ENGLEMAN, R
    TESTERMAN, L
    BRAULT, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 380 : 68 - 69
  • [25] The design and performance of a high resolution translational energy loss spectrometer
    Brenton, AG
    Lock, CM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (11) : 1155 - 1170
  • [26] A pulsed corona discharge switchable high resolution ion mobility spectrometer-mass spectrometer
    Hill, CA
    Thomas, CLP
    ANALYST, 2003, 128 (01) : 55 - 60
  • [27] Cluster Measurements at CLOUD using a High Resolution Ion Mobility Spectrometer - Mass Spectrometer Combination
    Adamov, Alexey
    Junninen, Heikki
    Duplissy, Jonathan
    Sipila, Mikko
    Kulmala, Markku
    NUCLEATION AND ATMOSPHERIC AEROSOLS, 2013, 1527 : 350 - 353
  • [28] Design of a photoelectron/ion imaging spectrometer with high temporal resolution
    Liu, Yuzhu
    Guan, Yue
    Ao, Kuang
    Pei, Shixin
    Gu, Fang
    Su, Jing
    Xu, Linhua
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [29] High Mass Resolution Multireflection Time-of-Flight Secondary Ion Mass Spectrometer
    Jiang, Jichun
    Hua, Lei
    Xie, Yuanyuan
    Cao, Yixue
    Wen, Yuxuan
    Chen, Ping
    Li, Haiyang
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (05) : 1196 - 1204
  • [30] Linear high resolution dust mass spectrometer for a mission to the Galilean satellites
    Kempf, Sascha
    Srama, Ralf
    Gruen, Eberhard
    Mocker, Anna
    Postberg, Frank
    Hillier, Jon K.
    Horanyi, Mihaly
    Sternovsky, Zoltan
    Abel, Bernd
    Beinsen, Alexander
    Thissen, Roland
    Schmidt, Juergen
    Spahn, Frank
    Altobelli, Nicolas
    PLANETARY AND SPACE SCIENCE, 2012, 65 (01) : 10 - 20