Stochastic model for predicting the temporal structure of the plan delivery in a synchrotron-based pencil beam scanning proton therapy system

被引:2
|
作者
Burguete, J. [1 ]
Garcia-Cardosa, M. [1 ]
Antolin, E. [2 ]
Aguilar, B. [2 ]
Azcona, J. D. [2 ]
机构
[1] Univ Navarra, Dept Phys & Appl Math, Irunlarrea 1, Pamplona 31008, Spain
[2] Clin Univ Navarra, Serv Radiat Phys & Radiat Protect, Marquesado Santa Marta 1, Madrid 28027, Spain
关键词
Proton therapy; Synchrotron; Stochastic model; Pencil beam scanning; Temporal structure of the beam; SPILL RIPPLE; TIME; MOTION; LUNG;
D O I
10.1016/j.radphyschem.2024.112276
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Accurately predicting dose delivery is crucial for achieving fully personalized treatments in external beam radiation therapy. However, this task remains challenging in some current technologies. In the case of Proton Therapy, for example, current systems employ complex strategies where a pencil beam is scanned in the tumor for treatment delivery. Some parameters in these treatments fluctuate and cannot be fully controlled. Therefore, a stochastic model that accounts for temporal uncertainties can be the best approach to describe these behaviors, particularly when the time-dependent beam interacts with other processes such as moving tumors or organs at risk. This paper aims to provide medical physicists with a tool for accurately predicting the temporal structure of beam delivery. To achieve this, we followed a two-step process. First, we characterized the probability distributions for all relevant times in dose delivery. Second, we developed a model based on the measured data. This model serves as a starting point to improve treatment planning performance by providing a range of expected times for dose delivery. While the process was carried out using a compact synchrotron at our university, it can be easily adapted to other technologies.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Efficiency of Respiratory-Gated Synchrotron Based Scanning Beam Delivery of Proton Therapy for Lung
    Tsunashima, Y.
    Vedam, S.
    Dong, L.
    Zhang, X.
    Umezawa, M.
    Smith, A.
    Balter, P.
    Mohan, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [22] Development and Validation of an Optimal GATE Model for Pencil Beam Scanning (PBS) Proton Beam Delivery
    Asadi, Ali
    Varnaseri, Seraj
    Moshiri, Shirin
    Akhavanallaf, Azadeh
    Arabi, Hossein
    Zaidi, Habib
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 471 - 474
  • [23] IH-DTL design with modified KONUS beam dynamics for a synchrotron-based proton therapy system
    Tang, Ruo
    Xing, Qingzi
    Zheng, Shuxin
    Guan, Xialing
    Tang, Chuanxiang
    Wang, Xuewu
    Shi, Jinshui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 920 : 50 - 57
  • [24] Effective Treatment Plan Integrity Verification for Passive Scattering and Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Ho, M.
    Liu, C.
    Liang, X.
    Johnson, P.
    Park, J.
    Artz, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] A Monte Carlo Model of a Spot Scanning Proton Beam. Based On a Synchrotron Proton Therapy Accelerator
    Xie, C.
    Lin, H.
    Jing, J.
    Chen, C.
    Cao, R.
    Pei, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3341 - 3341
  • [26] Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Smith, Blake R.
    Flynn, Ryan T.
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [27] Commissioning the beam model of apertures in a compact proton system using pencil beam scanning
    Perez Moreno, J. M.
    Vera Sanchez, J. A.
    Cerron Campoo, F.
    Castro Novais, J.
    Canals de las Casas, E.
    Lorenzo Villanueva, I.
    Sallabanda Hajro, M.
    Montero Feijoo, M.
    de Pablo Gonzalez, A.
    Matute Martin, R.
    Miralbell, R.
    Mazal, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1750 - S1751
  • [28] Development and Evaluation of a Pixel Detector System for Pencil Beam Scanning Proton Therapy
    Eichin, Michael
    Actis, O.
    Grossmann, M.
    Konig, S.
    Mayor, A.
    Meer, D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (07) : 1273 - 1279
  • [29] Investigation of dosimetric effect of beam current fluctuations in synchrotron-based proton PBS continuous scanning
    Liu, Chunbo
    Furutani, Keith M.
    Shen, Jiajian
    Tseung, Hok Wan Chan
    Tan, Hong Qi
    Li, Heng
    Whitaker, Thomas J.
    Beltran, Chris J.
    Liang, Xiaoying
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (13):
  • [30] Development and validation of an optimal GATE model for proton pencil-beam scanning delivery
    Asadi, Ali
    Akhavanallaf, Azadeh
    Hosseini, Seyed Abolfazl
    Vosoughi, Naser
    Zaidi, Habib
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (04): : 591 - 600