High-precision measurement of Wolter-I mandrel for X-ray microscopy by using double confocal probes

被引:0
|
作者
Xue, Chunan [1 ,3 ]
Yu, Jun [1 ,3 ]
Sheng, Pengfeng [1 ,2 ]
Wang, Haojie [1 ,3 ]
Wang, Zhanshan [1 ,3 ]
Wang, Dongfang [4 ]
机构
[1] Institute of Precision Optical Engineering, School of Physics Science and Engineering, Tongji University, Shanghai,200092, China
[2] School of Mechanical Engineering, Tongji University, Shanghai,200092, China
[3] Key Laboratory of Advanced Micro-structured Materials, Ministry of Education, Tongji University, Shanghai,200092, China
[4] Optoelectronic Manufacturing Engineering Center, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai,200092, China
关键词
D O I
10.37188/OPE.20243213.2004
中图分类号
学科分类号
摘要
The Wolter-type X-ray microscope, known for its high resolution and collecting area, is replacing KB-type X-ray microscopy in advanced light sources and high-energy lasers. A notable method for fabricating Wolter-type X-ray mirrors is nickel electroforming, where the surface accuracy and quality of the replication mandrel crucially impact mirror performance. Preparing the mandrel requires high-precision inspection technology, yet traditional equipment struggles to measure the circumferentially symmetric surface profile of the Wolter type. To address this challenge, we developed an offline detection device using a non-contact probe to measure the mandrel's middle and low frequency surface profile. Systematic and random errors in the detection device were analyzed, and we employed a dual-probe calibration method with a standard mirror, reducing the peak-to-valley (PV) value of drift due to temperature and humidity to 23 nm. A comparative experiment between our detection device and the CGH interferometric detection method showed a deviation of approximately 60 nm in the PV value of the surface test results for the Wolter mandrel, validating the effectiveness and accuracy of our detection method. © 2024 Chinese Academy of Sciences. All rights reserved.
引用
收藏
页码:2004 / 2016
相关论文
共 50 条
  • [21] HIGH-PRECISION X-RAY MASK TECHNOLOGY
    OHKI, S
    YOSHIHARA, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1990, 29 (11): : 2600 - 2604
  • [22] Constraint analysis of measurement accuracy in high-precision X-ray pulsar positioning
    Yao, Li
    Tong, Su
    Mei, Luan
    Zhang, Furui
    Zhu, Yechuan
    Yun, Du
    Zhao, Baosheng
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2020, 34 (30):
  • [23] APPLICATION OF THE FLUX FLOW EQUATION TO THE WOLTER-I X-RAY TELESCOPE AND THIN-FILM MULTILAYERED OPTICS
    CHAO, SH
    SHEALY, DL
    APPLIED OPTICS, 1986, 25 (12): : 1997 - 2002
  • [24] Point Spread Function of real Wolter-I X-ray mirrors: computation by means of the Huygens-Fresnel principle
    Raimondi, L.
    Spiga, D.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY V, 2011, 8147
  • [25] HIGH-PRECISION MEASUREMENT OF PHOSPHORUS IN GLASSES USING X-RAY-FLUORESCENCE
    MADDEN, M
    COX, JN
    FRUECHTING, B
    MATTEAU, J
    SOLID STATE TECHNOLOGY, 1989, 32 (08) : 53 - 55
  • [26] High-precision measurement of the wavelength of a nickel-like silver X-ray laser
    Hasegawa, N
    Kawachi, T
    Utsumi, T
    Sasaki, A
    Tanaka, M
    Kado, M
    Sukegawa, K
    Lu, PX
    Kishimoto, M
    Tai, RZ
    Nagashima, K
    Koike, M
    Daido, H
    Kato, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (5A): : 2519 - 2522
  • [27] High-precision measurement of the wavelength of a nickel-like silver X-ray laser
    Hasegawa, Noboru
    Kawachi, Tetsuya
    Utsumi, Takayuki
    Sasaki, Akira
    Tanaka, Momoko
    Kado, Masataka
    Sukegawa, Kouta
    Peixiang, Lu
    Kishimoto, Maki
    Renzhong, Tai
    Nagashima, Keisuke
    Koike, Masato
    Daido, Hiroyuki
    Kato, Yoshiaki
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2004, 43 (5 A): : 2519 - 2522
  • [28] SOFT-ELECTRON BACKGROUND IN X-RAY TELESCOPES USING WOLTER-I GRAZING-INCIDENCE OPTICS IN NEAR-EARTH ORBITS
    SUMNER, TJ
    LIEU, R
    OPTICAL ENGINEERING, 1990, 29 (10) : 1291 - 1295
  • [29] High-precision X-ray diffractometer on the base of acoustic monochromator
    A. R. Mkrtchyan
    A. H. Mkrtchyan
    V. R. Kocharyan
    A. E. Movsisyan
    S. B. Dabagov
    A. P. Potylicyn
    Journal of Contemporary Physics (Armenian Academy of Sciences), 2013, 48 : 141 - 143
  • [30] High-precision X-ray diffractometer on the base of acoustic monochromator
    Mkrtchyan, A. R.
    Mkrtchyan, A. H.
    Kocharyan, V. R.
    Movsisyan, A. E.
    Dabagov, S. B.
    Potylicyn, A. P.
    JOURNAL OF CONTEMPORARY PHYSICS-ARMENIAN ACADEMY OF SCIENCES, 2013, 48 (03) : 141 - 143