In-situ adaptive calibration of incident signal of ultrasonic lubricant film thickness measurements

被引:0
|
作者
Wu, Quanzhong [1 ]
Dou, Pan [1 ,2 ]
Chang, Shiyuan [1 ]
Wu, Tonghai [1 ]
Yu, Min [2 ]
Lei, Yaguo [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Educ, Minist Modern Design & Rotor Bearing Syst, Xian 710049, Shaanxi, Peoples R China
[2] Imperial Coll London, Dept Mech Engn, London SW7 2AZ, England
基金
中国国家自然科学基金;
关键词
Ultrasound; Film thickness; Adaptive calibration; Circle fitting;
D O I
10.1016/j.ymssp.2024.112236
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In ultrasonic reflection measurements of lubricant film thickness, an incident wave is needed as a reference signal and is typically calibrated under controlled ex-situ conditions. However, existing calibration methods have two limitations: 1) significant measurement errors are introduced due to the discrepancy between the calibration environment and the varying operational conditions (for example, temperature), and 2) disassembly of tribo-pairs is necessary. To address these issues, a novel method that enables in-situ adaptive calibration of incident signals is proposed. Particularly, it is found that the variation of the reflected signal against lubricant film thickness can well fit a circle in the polar coordinate, where the desirable incident signals can be extracted using the size and the location of the established circle. Importantly, the circle is iteratively updated to adapt to the variation of the working environment. This novel approach of calibrating incident signals, named the "circle-fitting method", does not require knowledge of the acoustic properties of tribo-pairs and is thus temperature independent. For experimental validation, two test setups of a micrometer-driven calibration rig and a tilting pad thrust bearing platform have been used separately to implement ultrasound measurements of lubricant film thickness, demonstrating accurate results as evidenced by error analysis. Specifically, in the experiment with the micrometer-driven calibration rig, the measurements yielded an amplitude estimation error of 0.2% and a phase estimation error of 0.66%.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] In-situ calibration of wire bonder ultrasonic system using integrated microsensor
    Mayer, Michael
    Paul, Oliver
    Bolliger, Daniel
    Baltes, Henry
    Proceedings of the Electronic Packaging Technology Conference, EPTC, 1998, : 219 - 223
  • [32] LUBRICANT FILM THICKNESS MEASUREMENTS IN A DIESEL-ENGINE PISTON RING ZONE
    LUX, JP
    HOULT, DP
    OLECHOWSKI, MJ
    LUBRICATION ENGINEERING, 1991, 47 (05): : 353 - 364
  • [33] Adaptive ultrasound reflectometry for lubrication film thickness measurements
    Kaeseler, R. L.
    Johansen, P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (02)
  • [34] IN-SITU THICKNESS CALIBRATION OF THIN TARGETS USED IN THE DETERMINATION OF STOPPING POWER
    UNTER, E
    EPPACHER, C
    SEMRAD, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 83 (04): : 577 - 580
  • [35] A simple in-situ optical film thickness monitor for infrared coatings
    Arora, VK
    Chopra, KN
    THIN SOLID FILMS, 1997, 304 (1-2) : 24 - 27
  • [36] In-situ measurement of optical film thickness in vacuum device fabrication
    Nanjing Univ of Science and, Technology, Nanjing, China
    Zhenkong Kexue yu Jishu Xuebao, 6 (441-443):
  • [37] Development of an in-situ thickness measurement technique for film growth by APCVD
    Rivero, JM
    Marsh, J
    Raisbeck, D
    JOURNAL DE PHYSIQUE IV, 1999, 9 (P8): : 1003 - 1011
  • [38] In situ simultaneous measurement of temperature and thin film thickness with ultrasonic techniques
    KhuriYakub, BT
    Pei, J
    Degertekin, FL
    Saraswat, KC
    NONDESTRUCTIVE EVALUATION FOR PROCESS CONTROL IN MANUFACTURING, 1996, 2948 : 131 - 135
  • [39] In situ simultaneous measurement of temperature and thin film thickness with ultrasonic techniques
    Pei, J
    KhuriYakub, BT
    Degertekin, FL
    Honein, BV
    Stanke, FE
    Saraswat, KC
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1039 - 1042
  • [40] The effect of titanium dioxide nanoparticles on bio-lubricant film thickness using ultrasonic reflection
    Kasolang, S.
    Mohamad, N. S.
    Bakar, M. A. A.
    Jumahat, A.
    Roselina, N. R. Nik
    PROCEEDINGS OF MALAYSIAN INTERNATIONAL TRIBOLOGY CONFERENCE 2015, 2015, : 324 - 326