In-situ adaptive calibration of incident signal of ultrasonic lubricant film thickness measurements

被引:0
|
作者
Wu, Quanzhong [1 ]
Dou, Pan [1 ,2 ]
Chang, Shiyuan [1 ]
Wu, Tonghai [1 ]
Yu, Min [2 ]
Lei, Yaguo [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Educ, Minist Modern Design & Rotor Bearing Syst, Xian 710049, Shaanxi, Peoples R China
[2] Imperial Coll London, Dept Mech Engn, London SW7 2AZ, England
基金
中国国家自然科学基金;
关键词
Ultrasound; Film thickness; Adaptive calibration; Circle fitting;
D O I
10.1016/j.ymssp.2024.112236
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In ultrasonic reflection measurements of lubricant film thickness, an incident wave is needed as a reference signal and is typically calibrated under controlled ex-situ conditions. However, existing calibration methods have two limitations: 1) significant measurement errors are introduced due to the discrepancy between the calibration environment and the varying operational conditions (for example, temperature), and 2) disassembly of tribo-pairs is necessary. To address these issues, a novel method that enables in-situ adaptive calibration of incident signals is proposed. Particularly, it is found that the variation of the reflected signal against lubricant film thickness can well fit a circle in the polar coordinate, where the desirable incident signals can be extracted using the size and the location of the established circle. Importantly, the circle is iteratively updated to adapt to the variation of the working environment. This novel approach of calibrating incident signals, named the "circle-fitting method", does not require knowledge of the acoustic properties of tribo-pairs and is thus temperature independent. For experimental validation, two test setups of a micrometer-driven calibration rig and a tilting pad thrust bearing platform have been used separately to implement ultrasound measurements of lubricant film thickness, demonstrating accurate results as evidenced by error analysis. Specifically, in the experiment with the micrometer-driven calibration rig, the measurements yielded an amplitude estimation error of 0.2% and a phase estimation error of 0.66%.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Accuracy-improved ultrasonic phase algorithm for measuring lubricant film thickness
    Wang, Jianyun
    He, Yanbo
    Wu, Jiaoyi
    Shu, Kun
    Zhang, Chuanwei
    Gu, Le
    Yu, Haide
    Wang, Tingjian
    Li, Zhen
    Wang, Liqin
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2024, 268
  • [22] An extended ultrasonic time-of-flight method for measuring lubricant film thickness
    Geng, Tao
    Meng, Qingfeng
    Xu, Xinping
    Wang, Peigong
    Yuan, Xiaoyang
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2015, 229 (07) : 861 - 869
  • [23] Lubricant Film Thickness Measurement Based on Ultrasonic Reflection Coefficient Phase Shift
    He Y.
    Gao T.
    Guo A.
    Qiao T.
    He C.
    Wang G.
    Liu X.
    Yang X.
    Mocaxue Xuebao/Tribology, 2021, 41 (01): : 1 - 8
  • [24] On-line measurement of lubricant film thickness using ultrasonic reflection coefficients
    Drinkwater, BW
    Dwyer-Joyce, RS
    Harper, P
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 23A AND 23B, 2004, 23 : 984 - 991
  • [25] Measurements of lubricant film thickness in reciprocating piston cylinder assemblies and engines
    Dellis, P.
    Arcoumanis, C.
    SECOND INTERNATIONAL CONFERENCE ON OPTICAL AND LASER DIAGNOSTICS, 2006, 45 : 161 - 161
  • [26] Measurements of lubricant film thickness in the iso-viscous elastohydrodynamic regime
    Gasni, D.
    Ibrahim, M. K. Wan
    Dwyer-Joyce, R. S.
    TRIBOLOGY INTERNATIONAL, 2011, 44 (7-8) : 933 - 944
  • [27] ESTIMATION OF IN-SITU STRESSES FROM ULTRASONIC MEASUREMENTS.
    Mao, N.H.
    Sweeney, J.J.
    SPE Formation Evaluation, 1986, 1 (05): : 532 - 538
  • [28] IN-SITU MEASUREMENTS OF FABRIC THICKNESS EVOLUTION DURING DRAPING
    Ivanov, D. S.
    Van Gestel, C.
    Lomov, S. V.
    Verpoest, I.
    14TH INTERNATIONAL CONFERENCE ON MATERIAL FORMING ESAFORM, 2011 PROCEEDINGS, 2011, 1353 : 924 - 929
  • [30] In-situ calibration of wire bonder ultrasonic system using integrated microsensor
    Mayer, M
    Paul, O
    Bolliger, D
    Baltes, H
    2ND ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, PROCEEDINGS, 1998, : 219 - 223