Real-time ultrasound shear wave elastography using a local phase gradient

被引:0
|
作者
González-Mateo, Enrique [1 ]
Camarena, Francisco [1 ]
Jiménez, Noé [1 ]
机构
[1] Instituto de Instrumentación para Imagen Molecular, Universitat Politècnica de València - CSIC, Camino de Vera s/n, València,46022, Spain
关键词
Frequency domain analysis;
D O I
10.1016/j.cmpb.2024.108529
中图分类号
学科分类号
摘要
Background and Objective: Current approaches for ultrasound spectral elastography make use of block processing, resulting in long computational times. This work describes a real-time, robust, and quantitative imaging modality to map the elastic and viscoelastic properties of soft tissues using ultrasound. Methods: This elastographic technique relies on the spectral estimation of the shear-wave phase speed by combining a local phase-gradient method and angular filtering. We first apply directional filtering in the spatio-temporal frequency domain for providing one-way, smooth, and harmonic displacement maps in the frequency range of interest. Thanks to this, we can apply a simple, fast, and local phase gradient approach to obtain the axial and lateral components of the wavevector, which are linked to phase velocity and soft-tissue elasticity and viscoelasticity. The technique is validated numerically and experimentally using a 7.6 MHz ultrasound probe, tested in calibrated soft-tissue phantoms and ex vivo liver tissues. The method is compared with state-of-the-art spectral methods. Results: The technique significantly reduces the computation time, e.g., the reconstruction time for a 155 × 315-pixel phase-velocity map was 0.16 s, while local-phase velocity-imaging techniques was 156.73 s for 2D implementation and 13.56 s for the 1D version, a reduction between two and three orders of magnitude, while showing a similar accuracy and resolution than standard methods. Conclusions: This approach eliminates the need for block processing that may limit the spatial resolution and computational time of the velocity map. In this way, the phase gradient elastography method is revealed as an efficient and robust approach for real-time spectral elastography. © 2024 The Authors
引用
收藏
相关论文
共 50 条
  • [21] Application value of conventional ultrasound and real-time shear wave elastography in patients with type 2 diabetic polyneuropathy
    Chen, Rui
    Wang, Xiao-Lei
    Xue, Wei-Li
    Sun, Jia-Wei
    Dong, Xue-Ying
    Jiang, Zhao-Peng
    Wu, Han
    Ma, Rao
    Zhou, Xian-Li
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [22] NAFLD evaluation: Which is more appropriate, multislice computed tomography or ultrasound real-time shear wave elastography?
    Lei, Pinggui
    Jiao, Jun
    Li, Hong
    Wang, Pingxian
    Duan, Qinghong
    Liu, Jing
    Zhou, Shi
    Wei, Qian
    Wang, Xiaolin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (05) : 871 - 883
  • [23] REAL TIME QUANTITATIVE ELASTOGRAPHY USING SUPERSONIC SHEAR WAVE IMAGING
    Tanter, Mickael
    Pernot, Mathieu
    Montaldo, Gabriel
    Gennisson, Jean-Luc
    Bavu, Eric
    Mace, Emilie
    Nguyen, Thu-Mai
    Couade, Mathieu
    Fink, Mathias
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 276 - 279
  • [24] Real-time shear wave elastography may predict autoimmune thyroid disease
    Vlad, Mihaela
    Golu, Ioana
    Bota, Simona
    Vlad, Adrian
    Timar, Bogdan
    Timar, Romulus
    Sporea, Ioan
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (9-10) : 330 - 336
  • [25] Real-time shear wave elastography may predict autoimmune thyroid disease
    Mihaela Vlad
    Ioana Golu
    Simona Bota
    Adrian Vlad
    Bogdan Timar
    Romulus Timar
    Ioan Sporea
    Wiener klinische Wochenschrift, 2015, 127 : 330 - 336
  • [26] Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave Elastography
    Correas, Jean-Michel
    Tissier, Anne-Marie
    Khairoune, Ahmed
    Vassiliu, Viorel
    Mejean, Arnaud
    Helenon, Olivier
    Memo, Richard
    Barr, Richard G.
    RADIOLOGY, 2015, 275 (01) : 280 - 289
  • [27] Application of real-time shear wave elastography in the assessment of torsional cervical dystonia
    Song, Ye
    Zhang, Tian-Jie
    Li, Yuan
    Gao, Yuan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (04) : 662 - 670
  • [28] Evaluation of normal and pathological Achilles tendon by real-time shear wave elastography
    Petrescu, Pompiliu Horatiu
    Izvernariu, Dragos Andrei
    Iancu, Catalina
    Dinu, Gabriel Ovidiu
    Crisan, Dan
    Popescu, Simona Alina
    Sirli, Roxana Lucia Denisa
    Nistor, Bogdan Mihai
    Rautia, Ion Calin
    Lazureanu, Dorela Codruta
    Dema, Sorin
    Prejbeanu, Ion Radu
    Sporea, Ioan
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2016, 57 (02): : 785 - 790
  • [29] Diagnostic role of real-time shear wave elastography on staging of liver fibrosis
    Xue, Yan
    Zhu, Qing
    Chen, Yuanzheng
    Bai, Nan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (08): : 12911 - 12917
  • [30] Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography
    Hao, Chang-Juan
    Kang, Xiao-Yan
    Kang, Chun-Song
    Li, Ting-Ting
    Huo, Jian-Zhong
    Xu, Qian
    Xiao, Wen-Li
    Zhao, Zhe-Xia
    Ji, Xing-Hua
    Zhang, Quan-Bin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 5168 - 5181