Real-time ultrasound shear wave elastography using a local phase gradient

被引:0
|
作者
González-Mateo, Enrique [1 ]
Camarena, Francisco [1 ]
Jiménez, Noé [1 ]
机构
[1] Instituto de Instrumentación para Imagen Molecular, Universitat Politècnica de València - CSIC, Camino de Vera s/n, València,46022, Spain
关键词
Frequency domain analysis;
D O I
10.1016/j.cmpb.2024.108529
中图分类号
学科分类号
摘要
Background and Objective: Current approaches for ultrasound spectral elastography make use of block processing, resulting in long computational times. This work describes a real-time, robust, and quantitative imaging modality to map the elastic and viscoelastic properties of soft tissues using ultrasound. Methods: This elastographic technique relies on the spectral estimation of the shear-wave phase speed by combining a local phase-gradient method and angular filtering. We first apply directional filtering in the spatio-temporal frequency domain for providing one-way, smooth, and harmonic displacement maps in the frequency range of interest. Thanks to this, we can apply a simple, fast, and local phase gradient approach to obtain the axial and lateral components of the wavevector, which are linked to phase velocity and soft-tissue elasticity and viscoelasticity. The technique is validated numerically and experimentally using a 7.6 MHz ultrasound probe, tested in calibrated soft-tissue phantoms and ex vivo liver tissues. The method is compared with state-of-the-art spectral methods. Results: The technique significantly reduces the computation time, e.g., the reconstruction time for a 155 × 315-pixel phase-velocity map was 0.16 s, while local-phase velocity-imaging techniques was 156.73 s for 2D implementation and 13.56 s for the 1D version, a reduction between two and three orders of magnitude, while showing a similar accuracy and resolution than standard methods. Conclusions: This approach eliminates the need for block processing that may limit the spatial resolution and computational time of the velocity map. In this way, the phase gradient elastography method is revealed as an efficient and robust approach for real-time spectral elastography. © 2024 The Authors
引用
收藏
相关论文
共 50 条
  • [1] Shear Wave Velocity Estimation Using the Real-Time Curve Tracing Method in Ultrasound Elastography
    Li, Yu
    Lv, Qian
    Dai, Jiayue
    Tian, Ye
    Guo, Jianzhong
    APPLIED SCIENCES-BASEL, 2021, 11 (05): : 1 - 15
  • [2] Qualitative Assessment of the Diaphragm in the Mechanically Ventilated Critically Ill Using Real-Time Shear Wave Ultrasound Elastography
    Jung, B.
    Flatres, A.
    Aarab, Y.
    Molinari, N.
    Matecki, S.
    Amalric, M.
    Larcher, R.
    Jaber, S.
    Klouche, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [3] Determination of Normal Skin Elasticity by Using Real-time Shear Wave Elastography
    Yang, Yujia
    Wang, Liyun
    Yan, Feng
    Xiang, Xi
    Tang, Yuanjiao
    Zhang, Lingyan
    Liu, Jibin
    Qiu, Li
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (11) : 2507 - 2516
  • [4] Real-time ultrasound elastography
    Bae, Unmin
    Kim, Yongmin
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [5] Associations of Real-Time Ultrasound and Strain and Shear Wave Elastography with Gastrointestinal Organs: A Systematic Review
    Javed, Nismat
    Ghazanfar, Haider
    Jyala, Abhilasha
    Patel, Harish
    DIAGNOSTICS, 2023, 13 (21)
  • [6] Analysis of transient shear wave generation for real-time elastography
    Yagi, S
    Sanuga, A
    Kondo, Y
    Tamura, K
    Sato, A
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1356 - 1359
  • [7] Determination of Normal Hepatic Elasticity by Using Real-time Shear-wave Elastography
    Suh, Chong Hyun
    Kim, So Yeon
    Kim, Kyoung Won
    Lim, Young-Suk
    Lee, So Jung
    Lee, Moon-Gyu
    Lee, JungBok
    Lee, Sung-Gyu
    Yu, Eunsil
    RADIOLOGY, 2014, 271 (03) : 895 - 900
  • [8] Evaluation of fatty liver fibrosis in rabbits using real-time shear wave elastography
    Lu, Yongping
    Wei, Jia
    Tang, Yueyue
    Yuan, Yuan
    Huang, Yanling
    Zhang, Yong
    Li, Yunyan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 8 (02) : 355 - 362
  • [9] Point shear wave ultrasound elastography with Esaote compared to real-time 2D shear wave elastography with supersonic imagine for the quantification of liver stiffness
    Mulazzani L.
    Salvatore V.
    Ravaioli F.
    Allegretti G.
    Matassoni F.
    Granata R.
    Ferrarini A.
    Stefanescu H.
    Piscaglia F.
    Journal of Ultrasound, 2017, 20 (3) : 213 - 225
  • [10] Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion
    Sun, Zhenxing
    Xie, Mingxing
    Xiang, Feixiang
    Song, Yue
    Yu, Cheng
    Zhang, Yanrong
    Ramdhany, Sachin
    Wang, Jing
    PLOS ONE, 2015, 10 (09):