A new integration method of fault line detection in resonant earthed system based on instantaneous real power and instantaneous virtual power

被引:0
|
作者
Li, Bin [1 ]
Shu, Hongchun [1 ]
机构
[1] Kunming University of Science and Technology, Kunming 650051, China
关键词
Damping - Electric fault currents - Integration - Fault detection - Virtual Power Plants;
D O I
暂无
中图分类号
学科分类号
摘要
The accident transition information is not only complex but also enrichment when single-phase-to-ground fault occurs in resonant earthed system. A new integration method of fault line detection based on instantaneous real power and instantaneous virtual power is proposed in this paper. Not as health lines, when single-phase-to-ground fault occurs in resonant earthed system, the grounded current of faulty line contains distinct transition damping oscillation direct current component with the compensation of arc suppressing. The damping oscillation direct current component shows the characteristics obviously of damping oscillation of industrial frequency through the analyses of instantaneous real power and instantaneous virtual power. Here, the characteristic frequency of 50 Hz in instantaneous power theory is defined. By calculating the instantaneous real power and instantaneous virtual power respectively of each line after single-phase-to-ground fault occurred, the oscillator components can be decomposed. Through comprehensively analyzing the value of oscillator components with the characteristic frequency of instantaneous real power and instantaneous virtual power, the integration algorithm of fault line detection can be established. The new method makes full use of transition information without considering phase position and multiple distinguish. Large amount of simulation results shows that the proposed method is accurate and reliable.
引用
收藏
页码:183 / 190
相关论文
共 50 条
  • [1] Faulty line detection based on instantaneous zero-sequence power for resonant earthed system
    Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
    Li, B. (kmlb@vip.sina.com), 2013, Electric Power Automation Equipment Press (33):
  • [2] Fault analysis method for a power line based on instantaneous phase consistency
    Luo J.
    Jiang L.
    Cui Q.
    Zhong J.
    Zhang L.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (21): : 178 - 186
  • [3] A New Bearing Fault Detection Method in Induction Machines Based on Instantaneous Power Factor
    Ibrahim, Ali
    El Badaoui, Mohamed
    Guillet, Francois
    Bonnardot, Ferderic
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) : 4252 - 4259
  • [4] Multilevel Inverter Compensation System of the Single-phase Based on Instantaneous P-instantaneous Real Power and Q-instantaneous Virtual Power Theory
    Wang, Xijuan
    Zhou, Tao
    Zhao, Yang
    Feng, Jingxiao
    Zhang, Jialun
    Zhang, Hongjun
    INTERNATIONAL JOURNAL OF ONLINE ENGINEERING, 2015, 11 (07) : 47 - 50
  • [5] Identification of Single-Phase Reclosing Fault on AC Line Based on Virtual Instantaneous Power
    Ma, Jing
    Wu, Yuchong
    Li, Pei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3339 - 3350
  • [6] A Fault Line Detection Method Based on VMD and Phase Space Reconstruction for Resonant Earthed System
    Chen, Rongcheng
    Liao, Zhijun
    Wang, Weizhou
    Tang, Yunfeng
    Zhao, Liang
    Yue, Tong
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3967 - 3973
  • [7] Instantaneous Faults Detection in Power System
    Binns, Richard
    Al-Mamari, Salwa Juma
    Salehifar, Mehdi
    2018 TWENTIETH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2018, : 90 - 95
  • [8] Directional Fault Detection Based on Active Power Coefficient in Resonant-Earthed Distribution System
    Liu, Yuanlong
    Zhang, Hengxu
    Wang, Pengwei
    Xu, Bingyin
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2022, 17 (02) : 275 - 284
  • [9] A new harmonic power flow method based on the instantaneous power balance
    Madrigal, M
    Acha, E
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 655 - 662
  • [10] A study on photovoltaic power system based on instantaneous real and imaginary power control
    Iwane, H. (iwane@dove.kuee.kyoto-u.ac.jp), 1600, IEEE Power Engineering Society, IEEE Japan (Institute of Electrical and Electronics Engineers Inc.):