Directional Fault Detection Based on Active Power Coefficient in Resonant-Earthed Distribution System

被引:0
|
作者
Liu, Yuanlong [1 ,3 ]
Zhang, Hengxu [1 ]
Wang, Pengwei [2 ]
Xu, Bingyin [2 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan 250100, Peoples R China
[2] Shandong Univ Technol, Coll Elect & Elect Engn, Zibo 255000, Peoples R China
[3] Shandong Siji Technol Co LTD, Jinan 250021, Peoples R China
关键词
Earthing Fault; Active Power Coefficient; Frequency Band; Intermittent Fault; Measurement Error of Current Transformer;
D O I
10.1166/jno.2022.3195
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transients-based earth fault protections cannot trip reliably for earthing faults with high resistance in a small current distribution system due to low magnitude of the high-frequency transient signals. Directional protection based on zero-sequence active power can trip reliably only with the presence of damping resistor during fault, and can be used as back-up protection. Phase comparison method is not applicable to arcing fault and intermittent fault. Energy method also has a drawback because of its vulnerability to current transformer error. This method which use the active power coefficient of the zero-sequence signal which is lower than 100 Hz is proposed. This method determines the faulty point direction through this coefficient. Digital simulation and actual fault recordings data have verified the feasibility of the proposed method, and is not subject to measurement error of current transformer.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [1] Distributed fault-passage indicators versus central fault location: Comparison for reliability centred planning of resonant-earthed distribution systems
    Habib, Md Zakaria
    Zarkovic, Sanja Duvnjak
    Taylor, Nathaniel
    Hilber, Patrik
    Shayesteh, Ebrahim
    ENERGY REPORTS, 2023, 9 : 1731 - 1742
  • [2] Verbesserung der Erdschlusserfassung in gelöschten NetzenImprovement of earth fault protection in resonant-earthed grids
    L. H. Fickert
    e&i Elektrotechnik und Informationstechnik, 1999, 116 (11) : 642 - 648
  • [3] A new integration method of fault line detection in resonant earthed system based on instantaneous real power and instantaneous virtual power
    Li, Bin
    Shu, Hongchun
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2012, 27 (06): : 183 - 190
  • [4] Fault Line Selection in Resonant Earthed System Based on Morphological Peak-Valley Detection
    Shu H.
    Huang H.
    Tian X.
    Dong J.
    Huang R.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (01): : 228 - 233
  • [5] A Fault Line Detection Method Based on VMD and Phase Space Reconstruction for Resonant Earthed System
    Chen, Rongcheng
    Liao, Zhijun
    Wang, Weizhou
    Tang, Yunfeng
    Zhao, Liang
    Yue, Tong
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3967 - 3973
  • [6] Faulty line detection based on instantaneous zero-sequence power for resonant earthed system
    Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
    Li, B. (kmlb@vip.sina.com), 2013, Electric Power Automation Equipment Press (33):
  • [7] Correlation analysis for faulty feeder detection in resonant earthed system
    Faculty of Electric Engineering, Kunming University of Science and Technology, Kunming 650051, China
    不详
    不详
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2008, 9 (6-9+48):
  • [8] A method of fault line selection in resonant earthed system based on zero sequence impedance characteristic of lines
    Tang, Tao
    Huang, Chun
    Jiang, Yaqun
    Luo, Xunhua
    Liu, Penghui
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2016, 31 (20): : 192 - 201
  • [9] A Novel Fault Line Detection Method Based on 2-Order Accumulated Generating Operation Correlation Analysis for Resonant Earthed System
    Wei X.
    Wen B.
    1674, Power System Technology Press (41): : 1674 - 1682
  • [10] Study on the earthed fault detection method in indirectly earthed power system using summation of outgoing feeder measurement admittance mutual difference
    Tang, Yi
    Chen, Kui
    Chen, Qing
    Liu, Hao
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2005, 29 (11): : 69 - 73