Directional Fault Detection Based on Active Power Coefficient in Resonant-Earthed Distribution System

被引:0
|
作者
Liu, Yuanlong [1 ,3 ]
Zhang, Hengxu [1 ]
Wang, Pengwei [2 ]
Xu, Bingyin [2 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan 250100, Peoples R China
[2] Shandong Univ Technol, Coll Elect & Elect Engn, Zibo 255000, Peoples R China
[3] Shandong Siji Technol Co LTD, Jinan 250021, Peoples R China
关键词
Earthing Fault; Active Power Coefficient; Frequency Band; Intermittent Fault; Measurement Error of Current Transformer;
D O I
10.1166/jno.2022.3195
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transients-based earth fault protections cannot trip reliably for earthing faults with high resistance in a small current distribution system due to low magnitude of the high-frequency transient signals. Directional protection based on zero-sequence active power can trip reliably only with the presence of damping resistor during fault, and can be used as back-up protection. Phase comparison method is not applicable to arcing fault and intermittent fault. Energy method also has a drawback because of its vulnerability to current transformer error. This method which use the active power coefficient of the zero-sequence signal which is lower than 100 Hz is proposed. This method determines the faulty point direction through this coefficient. Digital simulation and actual fault recordings data have verified the feasibility of the proposed method, and is not subject to measurement error of current transformer.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [21] Wireless Power Transfer System Based on Magnetic Resonant Coupling with Directional Coupler
    Go, Sanghan
    Abramowicz, Adam
    PROCEEDINGS OF THE 2017 IEEE-APS TOPICAL CONFERENCE ON ANTENNAS AND PROPAGATION IN WIRELESS COMMUNICATIONS (APWC), 2017, : 197 - 198
  • [22] Fault Line Detection of Non-effectively Earthed Neutral System Based on Modulus Maximum Determining Polarity
    Yue Qing-yu
    Mu Long-hua
    Wang Li-yan
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1974 - 1977
  • [23] Method of fault area & section location for non-solidly earthed distribution system
    Zheng, G. (zhenggugping@126.com), 2012, Chinese Society for Electrical Engineering (32):
  • [24] Fault Line Detection Based on Cross Correlation Coefficient for Distribution Network with DG
    Gao, Jie
    Cheng, Qiming
    Wang, Xiaowei
    Tang, Fengren
    Zhang, Yu
    Yu, Deqing
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [25] Fault Line Detection Based on Cross Correlation Coefficient for Distribution Network with DG
    Gao, Jie
    Cheng, Qiming
    Wang, Xiaowei
    Tan, Fengren
    Zhang, Yu
    Yu, Deqing
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [26] Incremental Phase-Current Based Fault Passage Indication for Earth Faults in Resonant Earthed Networks
    Habib, Md Zakaria
    Taylor, Nathaniel
    ELECTRICITY, 2023, 4 (02): : 96 - 113
  • [27] Transient characteristics of single-phase-to-ground fault in the indirectly earthed power system
    Tang, Yi
    Chen, Kui
    Chen, Qing
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (11): : 175 - 179
  • [28] Active islanding detection method for inverter-based distribution generation power system
    Chiang, Wen-Jung
    Jou, Hurng-Liahng
    Wu, Jinn-Chang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 158 - 166
  • [29] Expert System Based Fault Detection of Power Transformer
    Nagpal, Tapsi
    Brar, Yadwinder Singh
    JOURNAL OF COMPUTATIONAL AND THEORETICAL NANOSCIENCE, 2015, 12 (02) : 208 - 214
  • [30] Rogowski coil-based autonomous fault management strategy using Karen Bell Transformation for earthed active distribution networks
    Esmail, Ehab M.
    Almalaq, Abdulaziz
    Alqunun, Khalid
    Ali, Ziad M.
    Aleem, Shady H. E. Abdel
    AIN SHAMS ENGINEERING JOURNAL, 2023, 14 (05)