A new integration method of fault line detection in resonant earthed system based on instantaneous real power and instantaneous virtual power

被引:0
|
作者
Li, Bin [1 ]
Shu, Hongchun [1 ]
机构
[1] Kunming University of Science and Technology, Kunming 650051, China
关键词
Damping - Electric fault currents - Integration - Fault detection - Virtual Power Plants;
D O I
暂无
中图分类号
学科分类号
摘要
The accident transition information is not only complex but also enrichment when single-phase-to-ground fault occurs in resonant earthed system. A new integration method of fault line detection based on instantaneous real power and instantaneous virtual power is proposed in this paper. Not as health lines, when single-phase-to-ground fault occurs in resonant earthed system, the grounded current of faulty line contains distinct transition damping oscillation direct current component with the compensation of arc suppressing. The damping oscillation direct current component shows the characteristics obviously of damping oscillation of industrial frequency through the analyses of instantaneous real power and instantaneous virtual power. Here, the characteristic frequency of 50 Hz in instantaneous power theory is defined. By calculating the instantaneous real power and instantaneous virtual power respectively of each line after single-phase-to-ground fault occurred, the oscillator components can be decomposed. Through comprehensively analyzing the value of oscillator components with the characteristic frequency of instantaneous real power and instantaneous virtual power, the integration algorithm of fault line detection can be established. The new method makes full use of transition information without considering phase position and multiple distinguish. Large amount of simulation results shows that the proposed method is accurate and reliable.
引用
收藏
页码:183 / 190
相关论文
共 50 条
  • [21] A new method for real time computation of power quality indices based on instantaneous space phasors
    Milanese, DL
    Ciric, RM
    UPEC 2004: 39TH INTERNATIONAL UNIVERSITITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2005, : 924 - 928
  • [22] Fault Line Selection in Resonant Earthed System Based on Morphological Peak-Valley Detection
    Shu H.
    Huang H.
    Tian X.
    Dong J.
    Huang R.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (01): : 228 - 233
  • [23] Detection of power swing and fault occurring simultaneously with power swing using instantaneous frequency
    Behrooz Taheri
    Sirus Salehimehr
    Farzad Razavi
    Mohammad Parpaei
    Energy Systems, 2020, 11 : 491 - 514
  • [24] Detection of power swing and fault occurring simultaneously with power swing using instantaneous frequency
    Taheri, Behrooz
    Salehimehr, Sirus
    Razavi, Farzad
    Parpaei, Mohammad
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2020, 11 (02): : 491 - 514
  • [25] Analysis and Calculation of the Instantaneous Power Based on a New Method of Load Identification
    Jiang, Jian
    Liu, Wen
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON ENERGY, 2013, : 297 - 303
  • [26] Analysis and Calculation of the Instantaneous Power Based on A New Method of Load Identification
    Jiang, Jian
    Liu, Wen
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [27] A new method for separating AC component of instantaneous real power and imaginary power suitable for active filters
    Nakata, A
    Ueda, A
    Torii, A
    PROCEEDINGS OF THE POWER CONVERSION CONFERENCE - NAGAOKA 1997, VOLS I AND II, 1997, : 719 - 724
  • [28] New two-terminal fault location algorithm based on instantaneous measurement of power system frequency
    Chen, Zheng
    Dong, Xin-Zhou
    Luo, Cheng-Mu
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2001, 21 (SUPPL.): : 106 - 109
  • [29] A new complementary method to instantaneous inactive power compensation
    Bina, MT
    PESC'03: 2003 IEEE 34TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1542 - 1547
  • [30] Fault detection and location in gears by the smoothed instantaneous power spectrum distribution
    Yesilyurt, I
    NDT & E INTERNATIONAL, 2003, 36 (07) : 535 - 542