FE analysis of fire-resistance performance of concrete filled steel tubular columns under different loading cases

被引:0
|
作者
Liu, Fa-Qi [1 ]
Yang, Hua [1 ]
机构
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
关键词
Loading - Finite element method - Tubular steel structures - Concretes - Tubes (components) - ABAQUS - Columns (structural);
D O I
暂无
中图分类号
学科分类号
摘要
There are two main loading cases for concrete filled steel tubular (CFST) columns in the real application, i. e. 1) loading applied simultaneously on the core concrete and steel tube, 2) loading only applied on the core concrete, also known as steel tube confined concrete (STCC) columns. With the proper material models under fire loading, ABAQUS finite element program was used to analyze the fire-resistant performance of CFST columns under these two loading cases, accounting for the interaction behavior between steel tube and core concrete. The analysis results indicate that compared with those under the first loading case, the CFST columns under the second loading case exhibit different expansion behavior and fire resistance. Parametric analysis was then conducted to investigate the influence of factors on the fire-resistant performance of STCC columns exposed to ISO-834 standard fire conditions, including load ratio, slenderness ratio, section dimensions, load eccentricity ratio, strength of steel and concrete, etc, conclusions obtained in this paper will provide some reference for the further research.
引用
收藏
页码:201 / 204
相关论文
共 50 条
  • [21] FE analysis of fire resistance of concrete filled CHS columns
    Zha, XX
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (06) : 769 - 779
  • [22] Burnout resistance of concrete-filled steel tubular (CFST) columns under realistic fire conditions
    Szymkuc, Wojciech
    Malendowski, Michal
    Glema, Adam
    ce/papers, 2023, 6 (3-4) : 2184 - 2188
  • [23] Fire performance of concrete-filled steel tubular columns strengthened by CFRP
    Civionics Research Centre, University of Western Sydney, Penrith, NSW 2751, Australia
    不详
    不详
    Steel Compos. Struct., 4 (307-324):
  • [24] Fire performance of stiffened concrete filled double skin steel tubular columns
    Shekastehband, B.
    Taromi, A.
    Abedi, K.
    FIRE SAFETY JOURNAL, 2017, 88 : 13 - 25
  • [25] Review of fire performance experiment of concrete-filled steel tubular columns
    Xiang, Kai
    Wang, Guohui
    Pan, Yanchong
    Progress in Industrial and Civil Engineering III, Pt 1, 2014, 638-640 : 1397 - 1401
  • [26] Fire performance of concrete-filled steel tubular columns strengthened by CFRP
    Tao, Zhong
    Wang, Zhi-Bin
    Han, Lin-Hai
    Uy, Brian
    STEEL AND COMPOSITE STRUCTURES, 2011, 11 (04): : 307 - 324
  • [27] Test research on fire resistance performance of bar-reinforced concrete filled steel tubular columns
    Wu, Xiaoli
    Han, Jinsheng
    Cheng, Wenrang
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2009, 39 (SUPPL. 2): : 174 - 178
  • [28] ENHANCEMENT OF THE FIRE RESISTANCE OF CONCRETE-FILLED STEEL TUBULAR COLUMNS BY USING HIGH PERFORMANCE STEELS
    Espinos, Ana
    Ibanez, Carmen
    Lapuebla-Ferri, Andres
    Romero, Manuel L.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1470 - 1481
  • [29] Fire performance on steel-reinforced concrete-filled steel tubular columns with fire protection
    Mao, Wen-Jing
    Wang, Wen-Da
    Zhou, Kan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199
  • [30] Fire performance of concrete-filled tubular columns
    Lie, TT
    Kodur, VKR
    INTERNATIONAL CONFERENCE ON TUBULAR STRUCTURES, PROCEEDINGS, 1996, : 86 - 96