FE analysis of fire-resistance performance of concrete filled steel tubular columns under different loading cases

被引:0
|
作者
Liu, Fa-Qi [1 ]
Yang, Hua [1 ]
机构
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
关键词
Loading - Finite element method - Tubular steel structures - Concretes - Tubes (components) - ABAQUS - Columns (structural);
D O I
暂无
中图分类号
学科分类号
摘要
There are two main loading cases for concrete filled steel tubular (CFST) columns in the real application, i. e. 1) loading applied simultaneously on the core concrete and steel tube, 2) loading only applied on the core concrete, also known as steel tube confined concrete (STCC) columns. With the proper material models under fire loading, ABAQUS finite element program was used to analyze the fire-resistant performance of CFST columns under these two loading cases, accounting for the interaction behavior between steel tube and core concrete. The analysis results indicate that compared with those under the first loading case, the CFST columns under the second loading case exhibit different expansion behavior and fire resistance. Parametric analysis was then conducted to investigate the influence of factors on the fire-resistant performance of STCC columns exposed to ISO-834 standard fire conditions, including load ratio, slenderness ratio, section dimensions, load eccentricity ratio, strength of steel and concrete, etc, conclusions obtained in this paper will provide some reference for the further research.
引用
收藏
页码:201 / 204
相关论文
共 50 条
  • [41] Fire resistance of T-shaped concrete-filled steel tubular columns under eccentric compression
    Liu, Jiepeng
    Wei, Xuan
    Yang, Yuanlong
    Yang, Weiqi
    Chen, Y. Frank
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 187
  • [42] A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads
    Park, Su-Hee
    Choi, Sung-Mo
    Chung, Kyung-Soo
    STEEL AND COMPOSITE STRUCTURES, 2008, 8 (06): : 491 - 510
  • [43] Analysis on fire resistance of concrete-filled steel tube columns
    Yang, Hua
    Han, Lin-Hai
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2003, 35 (SUPPL.): : 93 - 96
  • [44] Nonlinear analysis and design of concrete-filled dual steel tubular columns under axial loading
    Wan, Cheng-Yong
    Zha, Xiao-Xiong
    STEEL AND COMPOSITE STRUCTURES, 2016, 20 (03): : 571 - 597
  • [45] Nonlinear analysis of circular concrete-filled steel tubular short columns under eccentric loading
    Liang, Qing Quan
    Fragomeni, Sam
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (02) : 159 - 169
  • [46] Behavior analysis of concrete-filled double skin steel tubular columns under axial loading
    Xu, Hanyong
    Yu, Zhiwu
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2011, 39 (12): : 123 - 127
  • [47] Nonlinear analysis of circular concrete-filled steel tubular short columns under axial loading
    Liang, Qing Quan
    Fragomeni, Sam
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (12) : 2186 - 2196
  • [48] Inelastic analysis of octagonal concrete-filled steel tubular short columns under eccentric loading
    Ahmed, Mizan
    Liang, Qing Quan
    Patel, Vipulkumar Ishvarbhai
    Hamoda, Ahmed
    STRUCTURAL CONCRETE, 2024, 25 (02) : 1418 - 1433
  • [49] Experimental study of concrete-filled steel tubular columns under blast loading
    Li, Guoqiang
    Qu, Haiyan
    Yang, Taochun
    Lu, Yong
    Chen, Suwen
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (12): : 69 - 76
  • [50] Nonlinear response of concrete-filled steel tubular columns under axial loading
    Shams, M
    Saadeghvaziri, MA
    ACI STRUCTURAL JOURNAL, 1999, 96 (06) : 1009 - 1017