Potentiometric PVC membrane ion–selective electrode for the determination of Sr(II) ions

被引:0
|
作者
Özbek O. [1 ]
机构
[1] Zonguldak Bülent Ecevit University, Science and Technology, Application and Research Center, Zonguldak
来源
Sensors International | 2022年 / 3卷
关键词
Ion–selective electrode; Potentiometry; PVC membrane; Strontium;
D O I
10.1016/j.sintl.2022.100185
中图分类号
学科分类号
摘要
In this study, an ion–selective electrode was developed for the potentiometric determination of strontium ions. Membrane optimization studies showed that the most suitable membrane composition was 4.0% (w/w) synthesized ionophore, 63.0% (w/w) bis(2–ethylhexyl)sebacate (BEHS), 32.0% (w/w) poly(vinyl chloride; PVC) and 1.0% (w/w) potassium tetrakis(p–chlorophenyl)borate (KTpClPB) in terms of potentiometric performance characteristics. The electrode, which exhibits a stable potentiometric behaviour, shows a linear response in the concentration range of 1.0 ​× ​10−5 – 1.0 ​× ​10−1 ​mol ​L−1 ​(R2 ​= ​0.998). The electrode has a detection limit of 7.94 ​× ​10−6 ​mol ​L−1 and a fast response time of 7s. The electrode exhibits selectivity against Sr(II) ions in the presence of some cationic species and works without being affected by pH changes in the pH range of 6.0–9.0. The proposed electrode performs the determination of Sr(II) ions in water samples with high recoveries. © 2022 The Authors
引用
收藏
相关论文
共 50 条
  • [21] POTENTIOMETRIC DETERMINATION OF THE BILE PHOSPHATES BY A LEAD ION-SELECTIVE MEMBRANE-ELECTRODE
    CAMPANELLA, L
    DASCENZO, G
    DEANGELIS, G
    TOMASSETTI, M
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 629 - 630
  • [22] POTENTIOMETRIC DETERMINATION OF EPHEDRINE HYDROCHLORIDE USING PLASTIC MEMBRANE ION-SELECTIVE ELECTRODE
    ZAREH, MM
    ISSA, YM
    SHOUKRY, AF
    SHOHAIB, RE
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1993, 58 (04) : 371 - 376
  • [23] POTENTIOMETRIC DETERMINATION OF SULFATE ION WITH THE FLUORIDE SELECTIVE ELECTRODE
    BOBRIKOVA, EI
    ANDREEVA, TB
    BARDIN, VV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1982, 37 (12): : 1687 - 1690
  • [24] THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
    Revenco, Mihail
    Martin, Mariana
    Abu Dayyih, Waell
    CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (01): : 73 - 77
  • [25] DETERMINATION OF CITRATE BY POTENTIOMETRIC TITRATION WITH COPPER(II) AND A COPPER ION-SELECTIVE ELECTRODE
    OLIN, A
    WALLEN, B
    ANALYTICA CHIMICA ACTA, 1983, 151 (01) : 65 - 75
  • [26] POTENTIOMETRIC DETERMINATION OF COPPER IN PALM OIL WITH A COPPER(II) ION-SELECTIVE ELECTRODE
    FUNG, YS
    FUNG, KW
    ANALYST, 1978, 103 (1223) : 149 - 155
  • [27] PREPARATION AND CHARACTERIZATION ION SELECTIVE ELECTRODE Cd(II) BASED ON CHITOSAN IN PVC MEMBRANE
    Panggabean, A. Sentosa
    INDONESIAN JOURNAL OF CHEMISTRY, 2011, 11 (03) : 285 - 289
  • [28] Determination of isoniazid using mercury(II) ion selective membrane electrode
    Srivastava, Bharti
    Chattopadhyaya, M. C.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2011, 88 (10) : 1615 - 1618
  • [29] Asymmetric Pt(II)-Porphyrin Incorporated in a PVC Ion-Selective Membrane for the Potentiometric Detection of Citrate
    Vlascici, Dana
    Lascu, Anca
    Fratilescu, Ion
    Anghel, Diana
    Epuran, Camelia
    Birdeanu, Mihaela
    Chiriac, Vlad
    Fagadar-Cosma, Eugenia
    CHEMOSENSORS, 2023, 11 (02)
  • [30] Cetylpyridinium-iodomercurate PVC membrane ion selective electrode for the determination of cetylpyridinium cation in Ezafluor mouth wash and as a detector for some potentiometric titrations
    Abbas, MN
    Mostafa, GAE
    Homoda, AMA
    TALANTA, 2000, 53 (02) : 425 - 432