PREPARATION AND CHARACTERIZATION ION SELECTIVE ELECTRODE Cd(II) BASED ON CHITOSAN IN PVC MEMBRANE

被引:7
|
作者
Panggabean, A. Sentosa [1 ]
机构
[1] Univ Mulawarman, Fac Math & Nat Sci, Dept Chem, Samarinda 75119, Indonesia
关键词
Ion Selective Electrodes; Cadmium; PVC membrane; Chitosan;
D O I
10.22146/ijc.21394
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Preparation of the chitosan membrane of ion-selective electrode for determination of cadmium ion has been conducted. Chitosan is a natural polymer containing nitrogen could coordinate with Cd2+ to increase the membrane conductivity value. Chitosan is a principal material and mixed with polyvinylchloride (PVC) as matrix dissolved previously to solvent tetrahydrofuran (THF) and dioctylphenylphosphonate (DOPP) is added as plasticizer by proportion chitosan: PVC: DOPP (6: 3: 1). To obtain the dopant optimum concentration, membrane was dipped in Cd2+ for 7 days and its conductivity value was measured using the four-point probe method. From FT-IR spectrum the peaks of amine, acetylamide and hydroxy groups wavelength number was observed to assure that Cd2+ bound to the chitosan. The optimum concentration of Cd2+ dopant was obtained at 1.00 M with conductivity value of 549.45 ohm(-1)m(-1) wich gave a Nernstian factor of 32.03 mV/decade with the detection limit of 2.512 x 10(-5) M. The electrodes work in the pH range 3 - 7. The life time of the electrode was 8 weeks. The ions of Ni2+, Fe3+, Pb2+, Cu2+, Zn2+, Cl and SO42- toward concentration range 10(-3) M gave response did not interfere in the determine of Cd2+ ion.
引用
收藏
页码:285 / 289
页数:5
相关论文
共 50 条
  • [1] Preparation and characterization of an atenolol selective electrode based on a PVC matrix membrane
    Nassory, Nabil S.
    Maki, Shahbaz A.
    Ali, Mutaz A.
    TURKISH JOURNAL OF CHEMISTRY, 2007, 31 (01) : 75 - 82
  • [2] PVC Membrane Selective Electrode for Determination of Cadmium(II) Ion in Chocolate Samples
    Chandra, Sulekh
    Singh, Deepshikha
    Sarkar, Anjana
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2014, 22 (04) : 480 - 488
  • [3] Potentiometric PVC membrane ion–selective electrode for the determination of Sr(II) ions
    Özbek O.
    Sensors International, 2022, 3
  • [4] PREPARATION AND CHARACTERIZATION OF AN ION-SELECTIVE ELECTRODE FOR COPPER(II)
    SRIVASTAVA, SK
    PAL, N
    SINGH, RP
    AGARWAL, S
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1983, 22 (12): : 1033 - 1036
  • [5] THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
    Revenco, Mihail
    Martin, Mariana
    Abu Dayyih, Waell
    CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (01): : 73 - 77
  • [6] Preparation and characterization of a diclofenac sensitive electrode based on a PVC matrix membrane
    Kormosh, Zholt
    Hunka, Iryna
    Bazel, Yaroslav
    ACTA CHIMICA SLOVENICA, 2008, 55 (02) : 261 - 267
  • [7] Preparation and Characterization of Pb(II) Ion Selective Electrode based on Dithizone as Chemical Sensor
    Panggabean, Aman Sentosa
    Gripaldi, Fakhry
    Pasaribu, Subur P.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (03): : 383 - 392
  • [8] A New PVC-Membrane Based Ion-Selective Electrode for Perchlorate
    Yari, Abdollah
    Shamsipur, Mojtaba
    De Filippo, Greta
    Lippolis, Vito
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2009, 1 (02): : 60 - 70
  • [9] Manganese(II)-selective PVC membrane electrode based on a pentaazamacrocyclic manganese complex
    Singh, AK
    Saxena, P
    Panwar, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) : 377 - 381
  • [10] Tin(II) Selective PVC Membrane Electrode Based on Salicylaldehyde Thiosemicarbazone as an Ionophore
    Chandra, Sulekh
    Sharma, Kusum
    Kumar, Adarsh
    JOURNAL OF CHEMISTRY, 2013, 2013