Asymmetric Pt(II)-Porphyrin Incorporated in a PVC Ion-Selective Membrane for the Potentiometric Detection of Citrate

被引:2
|
作者
Vlascici, Dana [1 ]
Lascu, Anca [2 ]
Fratilescu, Ion [2 ]
Anghel, Diana [2 ]
Epuran, Camelia [2 ]
Birdeanu, Mihaela [3 ]
Chiriac, Vlad [1 ]
Fagadar-Cosma, Eugenia [2 ]
机构
[1] West Univ Timisoara, Fac Chem Biol Geog, 4 Vasile Parvan Ave, Timisoara 300223, Romania
[2] Inst Chem Coriolan Dragulescu, Mihai Viteazu Ave 24, Timisoara 300223, Romania
[3] Natl Inst Res & Dev Electrochem & Condensed Matter, Plautius Andronescu St 1, Timisoara 300224, Romania
关键词
Pt-metalloporphyrin; A(3)B porphyrin; potentiometric sensor; PVC membrane; citrate ion detection; SOFT DRINKS; PI-PI; ELECTRODES; NANOPARTICLES; PORPHYRINS; PLATINUM(II); BEVERAGES; GRAPHITE; GRAPHENE; SENSOR;
D O I
10.3390/chemosensors11020108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensing material, Pt(II)-5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin (Pt(II)-COOH-TPOPP), was synthesized and characterized. Polymeric membranes containing the porphyrin and three different plasticizers were used as an electroactive material for a new anion-selective sensor. The best composition of the membrane was the one plasticized with dioctylsebacate (DOS), the obtained sensor being citrate-selective in a linear range of 5 x 10(-7)-1 x 10(-1) M citrate. The slope was Nernstian (19.73 mV/decade) with good selectivity towards a number of interfering anions and a lifetime of five weeks.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] DETERMINATION OF CITRATE BY POTENTIOMETRIC TITRATION WITH COPPER(II) AND A COPPER ION-SELECTIVE ELECTRODE
    OLIN, A
    WALLEN, B
    ANALYTICA CHIMICA ACTA, 1983, 151 (01) : 65 - 75
  • [2] THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
    Revenco, Mihail
    Martin, Mariana
    Abu Dayyih, Waell
    CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (01): : 73 - 77
  • [3] Potentiometric PVC membrane ion–selective electrode for the determination of Sr(II) ions
    Özbek O.
    Sensors International, 2022, 3
  • [4] Improvement of Lower Detection Limit of Ion-Selective Electrodes Based on PVC Membrane
    Huang Meirong
    Ding Yongbo
    Li Xingui
    PROGRESS IN CHEMISTRY, 2012, 24 (08) : 1560 - 1571
  • [5] ION-SELECTIVE ELECTRODE POTENTIOMETRIC DETECTION IN ION-CHROMATOGRAPHY
    ISILDAK, I
    COVINGTON, AK
    ELECTROANALYSIS, 1993, 5 (9-10) : 815 - 824
  • [6] Novel PVC membrane uranyl ion-selective sensor
    Saleh, MB
    Soliman, EM
    Gaber, AAA
    Ahmed, SA
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) : 199 - 205
  • [7] POTENTIOMETRIC ION-SELECTIVE, GAS-SELECTIVE, AND BIOSELECTIVE MEMBRANE ELECTRODES
    PRANITIS, DM
    TELTINGDIAZ, M
    MEYERHOFF, ME
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (03) : 163 - 186
  • [8] Thin polymeric membrane ion-selective electrodes for trace-level potentiometric detection
    Wang, Junhao
    Liang, Rongning
    Qin, Wei
    ANALYTICA CHIMICA ACTA, 2020, 1139 (1139) : 1 - 7
  • [9] Phenytoin speciation with potentiometric and chronopotentiometric ion-selective membrane electrodes
    Jansod, Sutida
    Afshar, Majid Ghahraman
    Crespo, Gaston A.
    Bakker, Eric
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 114 - 120
  • [10] POTENTIOMETRIC ION-SELECTIVE AND BIOSELECTIVE ELECTRODES BASED ON ASYMMETRIC POLYURETHANE MEMBRANES
    LIU, D
    MEYERHOFF, ME
    GOLDBERG, HD
    BROWN, RB
    ANALYTICA CHIMICA ACTA, 1993, 274 (01) : 37 - 46