Asymmetric Pt(II)-Porphyrin Incorporated in a PVC Ion-Selective Membrane for the Potentiometric Detection of Citrate

被引:2
|
作者
Vlascici, Dana [1 ]
Lascu, Anca [2 ]
Fratilescu, Ion [2 ]
Anghel, Diana [2 ]
Epuran, Camelia [2 ]
Birdeanu, Mihaela [3 ]
Chiriac, Vlad [1 ]
Fagadar-Cosma, Eugenia [2 ]
机构
[1] West Univ Timisoara, Fac Chem Biol Geog, 4 Vasile Parvan Ave, Timisoara 300223, Romania
[2] Inst Chem Coriolan Dragulescu, Mihai Viteazu Ave 24, Timisoara 300223, Romania
[3] Natl Inst Res & Dev Electrochem & Condensed Matter, Plautius Andronescu St 1, Timisoara 300224, Romania
关键词
Pt-metalloporphyrin; A(3)B porphyrin; potentiometric sensor; PVC membrane; citrate ion detection; SOFT DRINKS; PI-PI; ELECTRODES; NANOPARTICLES; PORPHYRINS; PLATINUM(II); BEVERAGES; GRAPHITE; GRAPHENE; SENSOR;
D O I
10.3390/chemosensors11020108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensing material, Pt(II)-5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin (Pt(II)-COOH-TPOPP), was synthesized and characterized. Polymeric membranes containing the porphyrin and three different plasticizers were used as an electroactive material for a new anion-selective sensor. The best composition of the membrane was the one plasticized with dioctylsebacate (DOS), the obtained sensor being citrate-selective in a linear range of 5 x 10(-7)-1 x 10(-1) M citrate. The slope was Nernstian (19.73 mV/decade) with good selectivity towards a number of interfering anions and a lifetime of five weeks.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] BEHAVIOR OF THE IODIDE ION-SELECTIVE ELECTRODE IN THE POTENTIOMETRIC TITRATION OF PALLADIUM(II) WITH IODIDE
    GEISSLER, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (03): : 188 - 191
  • [42] The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics
    Baek, Jonggyu
    Paeng, Insook Rhee
    JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY, 2008, 11 (01): : 59 - 63
  • [43] Polymeric plasticizer extends the lifetime of PVC-membrane ion-selective electrodes
    Zahran, Elsayed M.
    New, Andrea
    Gavalas, Vasilis
    Bachas, Leonidas G.
    ANALYST, 2014, 139 (04) : 757 - 763
  • [44] A PVC MATRIX MEMBRANE COPPER ION-SELECTIVE ELECTRODE BASED ON A MACROCYCLIC POLYTHIAETHER
    KAMATA, S
    HIGO, M
    KAMIBEPPU, T
    TANAKA, I
    CHEMISTRY LETTERS, 1982, (03) : 287 - 288
  • [45] Response of PVC membrane ion-selective electrodes to alkylmethylimidazolium ionic liquid cations
    Zhuo, Kelei
    Wei, Yujing
    Ma, Jingjing
    Chen, Yujuan
    Bai, Guangyue
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 : 461 - 465
  • [46] SOLID-STATE ION-SELECTIVE ELECTRODES FOR THE POTENTIOMETRIC DETERMINATION OF HEXACYANOFERRATE(II)
    IHN, GS
    SOHN, MJ
    BUCK, RP
    ANALYTICA CHIMICA ACTA, 1988, 209 (1-2) : 345 - 349
  • [47] POTENTIOMETRIC DETERMINATION OF COPPER IN PALM OIL WITH A COPPER(II) ION-SELECTIVE ELECTRODE
    FUNG, YS
    FUNG, KW
    ANALYST, 1978, 103 (1223) : 149 - 155
  • [48] Iodide ion-selective PVC membrane electrode based on a recently synthesized salen-Mn(II) complex
    Shamsipur, M
    Sadeghi, S
    Naeimi, H
    Sharghi, H
    POLISH JOURNAL OF CHEMISTRY, 2000, 74 (02) : 231 - 238
  • [49] PVC membrane, coated-wire, and carbon-paste ion-selective electrodes for potentiometric determination of galantamine hydrobromide in physiological fluids
    Abdel-Haleem, Fatehy M.
    Saad, Mohamed
    Barhoum, Ahmed
    Bechelany, Mikhael
    Rizk, Mahmoud S.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 89 : 140 - 148
  • [50] Potentiometric determination of Cd(II) ions using PVC-based polyaniline Sn(IV) silicate composite cation-exchanger ion-selective membrane electrode
    Naushad, Mu
    Inamuddin
    Rangreez, Tauseef Ahmad
    DESALINATION AND WATER TREATMENT, 2015, 55 (02) : 463 - 470