PVC membrane, coated-wire, and carbon-paste ion-selective electrodes for potentiometric determination of galantamine hydrobromide in physiological fluids

被引:35
|
作者
Abdel-Haleem, Fatehy M. [1 ]
Saad, Mohamed [1 ]
Barhoum, Ahmed [2 ]
Bechelany, Mikhael [3 ]
Rizk, Mahmoud S. [1 ]
机构
[1] Cairo Univ, Fac Sci, Chem Dept, Gamaa St, Giza 12613, Egypt
[2] Helwan Univ, Fac Sci, Chem Dept, Cairo 11795, Egypt
[3] Univ Montpellier, CNRS, ENSCM, Inst Europeen Membranes,UMR 5635, Pl Eugene Bataillon, F-34095 Montpellier 5, France
关键词
Electrochemical biosensors; Ion-selective electrodes; Galantamine hydrobromide; PVC membrane electrode; Carbon-paste electrode; Coated-wire electrode; Graphene oxide; ELECTROCHEMICAL ANALYSIS; SENSORS; GRAPHENE; COEFFICIENTS; MERCURY(II);
D O I
10.1016/j.msec.2018.04.001
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
We report on highly-sensitive ion-selective electrodes (ISEs) for potentiometric determining of galantamine hydrobromide (GB) in physiological fluids. Galantamine hydrobromide (GB) was selected for this study due to its previous medical importance for treating Alzheimer's disease. Three different types of ISEs were investigated: PVC membrane electrode (PVCE), carbon-paste electrode (CPE), and coated-wire electrode (CWE). In the construction of these electrodes, galantaminium-reineckate (GR) ion-pair was used as a sensing species for GB in solutions. The modified carbon-paste electrode (MCPE) was prepared using graphene oxide (MCPE-GO) and sodium tetrakis (trifluoromethyl) phenyl borate (MCPE-SIFPB) as ion-exchanger. The potentiometric modified CPEs (MCPE-GO and MCPE-SIFPB) show an improved performance in term of Nernstian slope, selectivity, response time, and response stability compared to the unmodified CPE. The prepared electrodes PVCE, CWE, CPE, MCPE-GO and MCPE-STFPB show Nemstian slopes of 59.9, 59.5, 58.1, 58.3 and 57.0 mV/conc. decade, and detection limits of 5.0 x 10(-6), 6.3 x 10(-6), 8.0 x 10(-6), 6.0 x 10(-6) and 8.0 x 10(-6) mol L-1, respectively. The prepared ISEs also show high selectivity against cations (i.e. Na+, K+, NH4+, Ca2+, Al3+, Fe3+), amino acids (i.e. glycine, L-alanine alanine), and sugars (i.e. fructose, glucose, maltose, lactose). The prepared ISEs are applicable for determining GB in spiked serums, urines, and pharmaceutical preparations, using a standard addition and a direct potentiometric method. The fast response time (<10 s), long lifetime (1-5 weeks), reversibility and stability of the measured signals facilitate the application of these sensors for routine analysis of the real samples.
引用
收藏
页码:140 / 148
页数:9
相关论文