Freeze-necking and volumetric change of clay during freezing by 3D x-ray computed tomography

被引:0
|
作者
Fan, Wenhu [1 ]
Wang, Jiaqi [1 ]
Zhang, Tao [1 ]
Zuo, Xi [1 ]
Xiao, Zhi [1 ]
He, Pengfei [2 ]
Shi, Xin [3 ]
机构
[1] Jinling Inst Technol, Sch Architectural Engn, Nanjing 211169, Jiangsu, Peoples R China
[2] Lanzhou Univ Technol, Sch Civil Engn, Lanzhou 730050, Gansu, Peoples R China
[3] Nanjing Forestry Univ, Sch Civil Engn, Nanjing 210037, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
freeze-necking; volumetric change; clay; freezing; three-dimensional x-ray computed tomography; PORE-WATER-PRESSURE; FROST HEAVE; SOIL; THAW;
D O I
10.1088/2053-1591/ad913d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In artificial freezing engineering, the freezing temperature is an important factor affecting soil frost heave deformation, and studying its impact is of great significance. The frost heave ratio of soil is a crucial factor for designing and predicting soil frost heave. However, it only considers vertical deformation while neglecting radial deformation. This paper introduces a simple unidirectional freezing apparatus specifically designed for three-dimensional x-ray computed tomography (CT) scanning, which allows for the investigation of internal structural changes in clay during freezing at four different freezing temperatures (i.e., -3 degrees C, -5 degrees C, -7 degrees C, and -9 degrees C). Freeze-necking of the soil was observed during freezing. An image processing method was proposed to segment the soil samples, and parameters such as length, equivalent diameter, and volume were measured to assess changes during freezing. The observed variations in necking depth and equivalent diameter indicate that freeze-necking is uniform. As the freezing temperature decreased, the necking depth reduced from 72.4 mm to 38.1 mm, and within this necking depth, the equivalent diameter decreased progressively from the bottom to the top. Moisture content increased near the cold end of the soil and decreased near the warm end, suggesting that freeze-necking is due to moisture migration within the soil. Considering freeze-necking, the volumetric frost heave ratio was defined to characterize soil frost heave deformation. This ratio also decreases as the freezing temperature decreases, and the values are smaller than those of the traditional frost heave ratio. The discrepancies become more pronounced at higher freezing temperatures, reaching up to 1.8% at -3 degrees C. The results indicate that lower freezing temperatures can reduce frost heave deformation, and freeze-necking requires greater attention in engineering at higher freezing temperature.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Deep 3D reconstruction of synchrotron X-ray computed tomography for intact lungs
    Seungjoo Shin
    Min Woo Kim
    Kyong Hwan Jin
    Kwang Moo Yi
    Yoshiki Kohmura
    Tetsuya Ishikawa
    Jung Ho Je
    Jaesik Park
    Scientific Reports, 13
  • [42] X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
    Holler, M.
    Diaz, A.
    Guizar-Sicairos, M.
    Karvinen, P.
    Farm, Elina
    Harkonen, Emma
    Ritala, Mikko
    Menzel, A.
    Raabe, J.
    Bunk, O.
    SCIENTIFIC REPORTS, 2014, 4
  • [43] X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
    M. Holler
    A. Diaz
    M. Guizar-Sicairos
    P. Karvinen
    Elina Färm
    Emma Härkönen
    Mikko Ritala
    A. Menzel
    J. Raabe
    O. Bunk
    Scientific Reports, 4
  • [44] Spatial and Fourier Analysis of Non-Stationarity in 3D X-Ray Computed Tomography
    Pineda, A.
    Tward, D.
    Gonzalez, A.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [45] In situ measurement of 3D contact angle in sand based on X-ray computed tomography
    Schlueter, Steffen
    Blaser, Sebastian R. G. A.
    Benard, Pascal
    Carminati, Andrea
    VADOSE ZONE JOURNAL, 2022, 21 (03)
  • [46] 3D composite reinforcement meso FE analyses based on X-ray computed tomography
    Naouar, N.
    Vidal-Salle, E.
    Schneider, J.
    Maire, E.
    Boisse, P.
    COMPOSITE STRUCTURES, 2015, 132 : 1094 - 1104
  • [47] X-ray Computed Tomography Characterization of 3D Tufted Twill Textile Composite for Aerostructures
    A.Saboktakin
    M.Shahrouz
    T.Vu-Khanh
    J.Bicerano
    JournalofHarbinInstituteofTechnology(NewSeries), 2019, 26 (03) : 7 - 13
  • [48] 3D imaging of fractures in carbonate rocks using X-ray computed tomography technology
    Jia, Lichun
    Chen, Mian
    Jin, Yan
    CARBONATES AND EVAPORITES, 2014, 29 (02) : 147 - 153
  • [49] 3D visualization of the biliary tree by X-ray phase-contrast computed tomography
    Damle-Vartak, Amruta
    ARCHIVES OF TOXICOLOGY, 2018, 92 (12) : 3601 - 3602
  • [50] 3D Non-Destructive Fluorescent X-Ray Computed Tomography With a CdTe Array
    Yoon, Changyeon
    Kim, Younghak
    Lee, Wonho
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1844 - 1853