X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution

被引:255
|
作者
Holler, M. [1 ]
Diaz, A. [1 ]
Guizar-Sicairos, M. [1 ]
Karvinen, P. [1 ]
Farm, Elina [2 ]
Harkonen, Emma [2 ]
Ritala, Mikko [2 ]
Menzel, A. [1 ]
Raabe, J. [1 ]
Bunk, O. [1 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Univ Helsinki, Dept Chem, FI-00014 Helsinki, Finland
来源
SCIENTIFIC REPORTS | 2014年 / 4卷
基金
芬兰科学院; 瑞士国家科学基金会;
关键词
PHASE RETRIEVAL; PILATUS;
D O I
10.1038/srep03857
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray ptychography is a scanning variant of coherent diffractive imaging with the ability to image large fields of view at high resolution. It further allows imaging of non-isolated specimens and can produce quantitative mapping of the electron density distribution in 3D when combined with computed tomography. The method does not require imaging lenses, which makes it dose efficient and suitable to multi-keV X-rays, where efficient photon counting, pixelated detectors are available. Here we present the first highly resolved quantitative X-ray ptychographic tomography of an extended object yielding 16 nm isotropic 3D resolution recorded at 2 angstrom wavelength. This first-of-its-kind demonstration paves the way for ptychographic X-ray tomography to become a promising method for X-ray imaging of representative sample volumes at unmatched resolution, opening tremendous potential for characterizing samples in materials science and biology by filling the resolution gap between electron microscopy and other X-ray imaging techniques.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
    M. Holler
    A. Diaz
    M. Guizar-Sicairos
    P. Karvinen
    Elina Färm
    Emma Härkönen
    Mikko Ritala
    A. Menzel
    J. Raabe
    O. Bunk
    Scientific Reports, 4
  • [2] Ptychographic X-ray computed tomography of porous membranes with nanoscale resolution
    Gorecki, Radoslaw
    Polo, Carla Cristina
    Kalile, Tiago Araujo
    Miqueles, Eduardo X. S.
    Tonin, Yuri R.
    Upadhyaya, Lakshmeesha
    Meneau, Florian
    Nunes, Suzana P.
    COMMUNICATIONS MATERIALS, 2023, 4 (01)
  • [3] Ptychographic X-ray computed tomography of porous membranes with nanoscale resolution
    Radosław Górecki
    Carla Cristina Polo
    Tiago Araujo Kalile
    Eduardo X. S. Miqueles
    Yuri R. Tonin
    Lakshmeesha Upadhyaya
    Florian Meneau
    Suzana P. Nunes
    Communications Materials, 4
  • [4] Ptychographic X-ray computed tomography at the nanoscale
    Martin Dierolf
    Andreas Menzel
    Pierre Thibault
    Philipp Schneider
    Cameron M. Kewish
    Roger Wepf
    Oliver Bunk
    Franz Pfeiffer
    Nature, 2010, 467 : 436 - 439
  • [5] Ptychographic X-ray computed tomography at the nanoscale
    Dierolf, Martin
    Menzel, Andreas
    Thibault, Pierre
    Schneider, Philipp
    Kewish, Cameron M.
    Wepf, Roger
    Bunk, Oliver
    Pfeiffer, Franz
    NATURE, 2010, 467 (7314) : 436 - U82
  • [6] X-ray computed tomography for 3D plant imaging
    Piovesan, Agnese
    Vancauwenberghe, Valerie
    Van de Looverbosch, Tim
    Verboven, Pieter
    Nicolai, Bart
    TRENDS IN PLANT SCIENCE, 2021, 26 (11) : 1171 - 1185
  • [7] Ptychographic X-ray computed tomography at a high-brilliance X-ray source
    Sala, Simone
    Batey, Darren J.
    Prakash, Anupama
    Ahmed, Sharif
    Rau, Christoph
    Thibault, Pierre
    OPTICS EXPRESS, 2019, 27 (02): : 533 - 542
  • [8] X-ray 3D computed tomography of bronze archaeological samples
    Rossi, M.
    Casali, F.
    Chirco, P.
    Morigi, M.P.
    Nava, E.
    Querzola, E.
    Zanarini, M.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 1 : 368 - 374
  • [9] X-ray 3D computed tomography of bronze archaeological samples
    Rossi, M
    Casali, F
    Chirco, P
    Morigi, MP
    Nava, E
    Querzola, E
    Zanarini, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 897 - 903
  • [10] X-ray 3D computed tomography of bronze archaeological samples
    Rossi, M.
    Casali, F.
    Chirco, P.
    Morigi, M.P.
    Nava, E.
    Querzola, E.
    Zanarini, M.
    IEEE Transactions on Nuclear Science, 1999, 46 (4 I): : 897 - 903