Direct Measurement of the Ciliary Sulcus Diameter Using Optical Coherence Tomography-Inter-Rater Variability

被引:0
|
作者
Eppig, Timo [1 ,2 ]
Seer, Manuel [2 ]
Martinez-Abad, Antonio [3 ]
Galvis, Virgilio [4 ,5 ]
Schuetz, Saskia [2 ]
Tello, Alejandro [4 ,5 ,6 ]
Rombach, Michiel C. [7 ]
Alio, Jorge L. [3 ]
机构
[1] Saarland Univ, Inst Expt Ophthalmol, D-66421 Homburg, Germany
[2] AMIPLANT GmbH, D-91220 Schnaittach, Germany
[3] Vissum Grp Miranza, Alicante 03016, Spain
[4] Ctr Oftalmol Virgilio Galvis, Floridablanca 681004, Colombia
[5] Univ Autonoma Bucamaranga UNAB, Fac Hlth, Dept Ophthalmol, Bucaramanga 680002, Colombia
[6] UIS, Dept Surg, Fac Hlth, Bucaramanga 680002, Colombia
[7] AKKOLENS Int Bv, NL-4836 BA Breda, Netherlands
关键词
ocular dimensions; optical coherence tomography; intraocular lens; ULTRASOUND BIOMICROSCOPY; REPEATABILITY; PARAMETERS; EYES;
D O I
10.3390/s24216950
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of sulcus-to-sulcus measurements has been challenging due to the limitations of current approaches. Ultrasound methods are highly operator-dependent and require extensive training, while traditional optical devices cannot visualize structures posterior to the iris. However, modern optical anterior segment coherence tomography (AS-OCT) devices are changing this paradigm by identifying some anatomical landmarks posterior to the iris. This study evaluates the reproducibility of optical sulcus measurements in the context of sizing a novel accommodative intraocular lens (IOL). Preoperative OCT scans of patients scheduled for cataract surgery were analyzed regarding the dimensions of the ciliary sulcus using a custom scan method with a clinically available anterior segment optical coherence tomographer. Measurements were compared between two different readers, and various derived parameters were compared. The measurements by both readers were highly correlated (R2 > 0.96), and their agreement was excellent (mean difference 0.02 mm with 95% limits of agreement from -0.11 to 0.15 mm). In contrast, the sulcus diameter measurement did not agree well with automatically calculated values, such as the anterior chamber width or white-to-white. This leads to the conclusion that modern swept-source AS-OCT measurements of the ciliary sulcus dimensions are feasible, reproducible, and may be a clinically useful tool.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Evaluation of hematocrit measurement using spectral domain optical coherence tomography
    Xu, Xiangqun
    Chen, Zhongping
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 615 - +
  • [42] Electrokinetic measurement of cartilage using differential phase optical coherence tomography
    Youn, JI
    Akkin, T
    Milner, TE
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 85 - 95
  • [43] Automated detection and measurement of epidermal thickness using optical coherence tomography
    Weissman, J
    Hancewicz, T
    Kaplan, P
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2005, 52 (03) : P36 - P36
  • [44] Film thickness measurement and defect inspection using optical coherence tomography
    Qin, Yuwei
    Zhao, Hong
    Zhang, Lu
    Wang, Liwei
    OPTIK, 2013, 124 (22): : 5293 - 5296
  • [45] Measurement of anisotropic reflection of flowing blood using optical coherence tomography
    Nam, Kweon-Ho
    Jeong, Bosu
    Jung, In Oh
    Ha, Hojin
    Kim, Ki Hean
    Lee, Sang Joon
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (12)
  • [46] In vitro determination of Mexican Mestizo hair shaft diameter using optical coherence tomography
    Abril Martinez-Velasco, Maria
    Perper, Marina
    Maddy, Austin J.
    Cervantes, Jessica
    Eber, Ariel E.
    Verne, Sebastian H.
    Elizabeth Vazquez-Herrera, Norma
    Nouri, Keyvan
    Tosti, Antonella
    SKIN RESEARCH AND TECHNOLOGY, 2018, 24 (02) : 274 - 277
  • [47] Simultaneous and localized measurement of diffusion and flow using optical coherence tomography
    Weiss, Nicolas
    van Leeuwen, Ton G.
    Kalkman, Jeroen
    OPTICS EXPRESS, 2015, 23 (03): : 3448 - 3459
  • [48] Retinal flow velocity measurement using optical coherence tomography angiography
    Fard, Ali
    Rikhter, Dmitry
    Sha, Patricia
    Wei, Wei
    Zhang, Qinqin
    Wang, Ruikang K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [49] Fully-automatic segmentation of the ciliary muscle using anterior segment optical coherence tomography images
    Goyanes, Elena
    de Moura, Joaquim
    Novo, Jorge
    Fernandez-Vigo, Jose Ignacio
    Fernandez-Vigo, Jose Angel
    Ortega, Marcos
    2022 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2022,
  • [50] External elastic lamina vs. luminal diameter measurement for determining stent diameter by optical coherence tomography: an ILUMIEN III substudy
    Shlofmitz, Evan
    Jeremias, Allen
    Parviz, Yasir
    Galougahi, Keyvan Karimi
    Redfors, Bjorn
    Petrossian, Gregory
    Edens, Madison
    Matsumura, Mitsuaki
    Maehara, Akiko
    Mintz, Gary S.
    Stone, Gregg W.
    Shlofmitz, Richard A.
    Ali, Ziad A.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2021, 22 (07) : 753 - 759