Direct Measurement of the Ciliary Sulcus Diameter Using Optical Coherence Tomography-Inter-Rater Variability

被引:0
|
作者
Eppig, Timo [1 ,2 ]
Seer, Manuel [2 ]
Martinez-Abad, Antonio [3 ]
Galvis, Virgilio [4 ,5 ]
Schuetz, Saskia [2 ]
Tello, Alejandro [4 ,5 ,6 ]
Rombach, Michiel C. [7 ]
Alio, Jorge L. [3 ]
机构
[1] Saarland Univ, Inst Expt Ophthalmol, D-66421 Homburg, Germany
[2] AMIPLANT GmbH, D-91220 Schnaittach, Germany
[3] Vissum Grp Miranza, Alicante 03016, Spain
[4] Ctr Oftalmol Virgilio Galvis, Floridablanca 681004, Colombia
[5] Univ Autonoma Bucamaranga UNAB, Fac Hlth, Dept Ophthalmol, Bucaramanga 680002, Colombia
[6] UIS, Dept Surg, Fac Hlth, Bucaramanga 680002, Colombia
[7] AKKOLENS Int Bv, NL-4836 BA Breda, Netherlands
关键词
ocular dimensions; optical coherence tomography; intraocular lens; ULTRASOUND BIOMICROSCOPY; REPEATABILITY; PARAMETERS; EYES;
D O I
10.3390/s24216950
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of sulcus-to-sulcus measurements has been challenging due to the limitations of current approaches. Ultrasound methods are highly operator-dependent and require extensive training, while traditional optical devices cannot visualize structures posterior to the iris. However, modern optical anterior segment coherence tomography (AS-OCT) devices are changing this paradigm by identifying some anatomical landmarks posterior to the iris. This study evaluates the reproducibility of optical sulcus measurements in the context of sizing a novel accommodative intraocular lens (IOL). Preoperative OCT scans of patients scheduled for cataract surgery were analyzed regarding the dimensions of the ciliary sulcus using a custom scan method with a clinically available anterior segment optical coherence tomographer. Measurements were compared between two different readers, and various derived parameters were compared. The measurements by both readers were highly correlated (R2 > 0.96), and their agreement was excellent (mean difference 0.02 mm with 95% limits of agreement from -0.11 to 0.15 mm). In contrast, the sulcus diameter measurement did not agree well with automatically calculated values, such as the anterior chamber width or white-to-white. This leads to the conclusion that modern swept-source AS-OCT measurements of the ciliary sulcus dimensions are feasible, reproducible, and may be a clinically useful tool.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Objective Measurement of Vitreous Inflammation Using Optical Coherence Tomography
    Keane, Pearse A.
    Karampelas, Michael
    Sim, Dawn A.
    Sadda, Srinivas R.
    Tufail, Adnan
    Sen, H. Nida
    Nussenblatt, Robert B.
    Dick, Andrew D.
    Lee, Richard W.
    Murray, Philip I.
    Pavesio, Carlos E.
    Denniston, Alastair K.
    OPHTHALMOLOGY, 2014, 121 (09) : 1706 - 1714
  • [22] CHOROIDAL THICKNESS MEASUREMENT IN CHILDREN USING OPTICAL COHERENCE TOMOGRAPHY
    Bidaut-Garnier, Melanie
    Schwartz, Claire
    Puyraveau, Marc
    Montard, Michel
    Delbosc, Bernard
    Saleh, Maher
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (04): : 768 - 774
  • [23] Wire bias in coronary measurement using optical coherence tomography
    Danson E.J.
    Hansen P.
    Bhindi R.
    Cardiovascular Intervention and Therapeutics, 2018, 33 (3) : 217 - 223
  • [24] Contactless measurement of fabric thickness using optical coherence tomography
    Sabuncu, Metin
    Ozdemir, Hakan
    JOURNAL OF THE TEXTILE INSTITUTE, 2022, 113 (05) : 713 - 717
  • [25] Flow measurement using speckle in optical coherence tomography images
    Barton, JK
    Stromski, S
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 245 - 256
  • [26] Automated contact lens measurement using optical coherence tomography
    Davidson, Bryan R.
    Barton, Jennifer K.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VII, 2009, 7169
  • [27] Retinal blood flow measurement by using optical coherence tomography
    Makita, Shuichi
    Fabritius, Tapio
    Miura, Masahiro
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XII, 2008, 6847
  • [28] Intra and inter-rater agreement of anterior lamina cribrosa depth measurements using enhanced-depth imaging optical coherence tomography
    Leal, I.
    Sousa, D. Cordeiro
    Couceiro, R.
    Barata, A.
    Pinto, L. Abegao
    Pinto, F.
    Marques-Neves, C.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [29] In vivo assessment of ciliary muscle morphology using swept source optical coherence tomography
    Szostek, Nicola
    Buckhurst, Hetal D.
    Collinson, Avril
    Purslow, Christine
    Buckhurst, Phillip J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [30] Chromatic dispersion measurement of optical fiber using spectroscopic optical coherence tomography
    Chen, Shen
    Yang, Yaliang
    Yang, Fan
    Huang, Qixiang
    OPTICS AND LASERS IN ENGINEERING, 2024, 183