Direct Measurement of the Ciliary Sulcus Diameter Using Optical Coherence Tomography-Inter-Rater Variability

被引:0
|
作者
Eppig, Timo [1 ,2 ]
Seer, Manuel [2 ]
Martinez-Abad, Antonio [3 ]
Galvis, Virgilio [4 ,5 ]
Schuetz, Saskia [2 ]
Tello, Alejandro [4 ,5 ,6 ]
Rombach, Michiel C. [7 ]
Alio, Jorge L. [3 ]
机构
[1] Saarland Univ, Inst Expt Ophthalmol, D-66421 Homburg, Germany
[2] AMIPLANT GmbH, D-91220 Schnaittach, Germany
[3] Vissum Grp Miranza, Alicante 03016, Spain
[4] Ctr Oftalmol Virgilio Galvis, Floridablanca 681004, Colombia
[5] Univ Autonoma Bucamaranga UNAB, Fac Hlth, Dept Ophthalmol, Bucaramanga 680002, Colombia
[6] UIS, Dept Surg, Fac Hlth, Bucaramanga 680002, Colombia
[7] AKKOLENS Int Bv, NL-4836 BA Breda, Netherlands
关键词
ocular dimensions; optical coherence tomography; intraocular lens; ULTRASOUND BIOMICROSCOPY; REPEATABILITY; PARAMETERS; EYES;
D O I
10.3390/s24216950
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of sulcus-to-sulcus measurements has been challenging due to the limitations of current approaches. Ultrasound methods are highly operator-dependent and require extensive training, while traditional optical devices cannot visualize structures posterior to the iris. However, modern optical anterior segment coherence tomography (AS-OCT) devices are changing this paradigm by identifying some anatomical landmarks posterior to the iris. This study evaluates the reproducibility of optical sulcus measurements in the context of sizing a novel accommodative intraocular lens (IOL). Preoperative OCT scans of patients scheduled for cataract surgery were analyzed regarding the dimensions of the ciliary sulcus using a custom scan method with a clinically available anterior segment optical coherence tomographer. Measurements were compared between two different readers, and various derived parameters were compared. The measurements by both readers were highly correlated (R2 > 0.96), and their agreement was excellent (mean difference 0.02 mm with 95% limits of agreement from -0.11 to 0.15 mm). In contrast, the sulcus diameter measurement did not agree well with automatically calculated values, such as the anterior chamber width or white-to-white. This leads to the conclusion that modern swept-source AS-OCT measurements of the ciliary sulcus dimensions are feasible, reproducible, and may be a clinically useful tool.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] In Vivo Measurement of the Attenuation Coefficient of the Sclera and Ciliary Muscle from Transscleral Optical Coherence Tomography images
    Mesquita, Gabrielle Monterano
    Chang, Yu-Cherng
    Cabot, Florence
    Ruggeri, Marco
    Yoo, Sonia H.
    Parel, Jean-Marie A.
    Manns, Fabrice
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [32] Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging
    Uechi, Yuna
    Nakamura, Kentaro
    Shinozuka, Masato
    Kawasaki, Shohei
    Okawa, Kazuyoshi
    Inoue, Tatsuya
    Asaoka, Ryo
    Maruyama-Inoue, Maiko
    Yanagi, Yasuo
    Kadonosono, Kazuaki
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (10):
  • [33] Variability of Vessel Caliber Measurement in En Face Optical Coherence Tomography Angiography Images
    Tsai, Joby
    Zhang, Xuemin
    Tracey, Breanna
    Saeedi, Osamah
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [34] Inter-rater reliability of optic nerve sheath diameter measurement using real-time ultrasonography
    Jennings, Jason B.
    Oliva, Cynthia
    Joyce, Michael
    Vitto, Michael J.
    Tozer, Jordan
    Taylor, Lindsay A.
    Evans, David P.
    ULTRASOUND JOURNAL, 2022, 14 (01):
  • [35] Inter-rater reliability of optic nerve sheath diameter measurement using real-time ultrasonography
    Jason B. Jennings
    Cynthia Oliva
    Michael Joyce
    Michael J. Vitto
    Jordan Tozer
    Lindsay A. Taylor
    David P. Evans
    The Ultrasound Journal, 14
  • [36] Classification of human gingival sulcus using swept-source optical coherence tomography: In vivo imaging
    Lee, Jaeyul
    Park, Jaeseok
    Shirazi, Muhammad Faizan
    Jo, Hosung
    Kim, Pilun
    Wijesinghe, Ruchire Eranga
    Jeon, Mansik
    Kim, Jeehyun
    INFRARED PHYSICS & TECHNOLOGY, 2019, 98 : 155 - 160
  • [37] Intra- and Inter-Rater Agreement of Anterior Lamina Cribrosa Depth Measurements Using Enhanced-Depth Imaging Optical Coherence Tomography
    Leal, Ines
    Sousa, David Cordeiro
    Pinto, Filomena
    Marques-Neves, Carlos
    Pinto, Luis Abegao
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 92 - 99
  • [38] Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
    Dong, Jing
    Yao, Jinhan
    Chang, Shuimiao
    Kanclerz, Piotr
    Khoramnia, Ramin
    Wang, Xiaogang
    MEDICINA-LITHUANIA, 2023, 59 (05):
  • [39] Diameter-dependent classification of dermal vasculature using optical coherence tomography angiography
    Hoshino, Takuma
    Cheng, Yuxuan
    Ninomiya, Masato
    Katsuyama, Masako
    Yamashita, Toyonobu
    Katagiri, Chika
    Wang, Ruikang K.
    Hara, Yusuke
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (09) : 6238 - 6249
  • [40] Measurement of biofilm growth and local hydrodynamics using optical coherence tomography
    Weiss, Nicolas
    El Obied, Khalid El Tayeb
    Kalkman, Jeroen
    Lammertink, Rob G. H.
    van Leeuwen, Ton G.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (09): : 3508 - 3518