Performance evaluation of a central air conditioning system using condensate as a discharge line cooler

被引:0
|
作者
Sumeru, Kasni [1 ]
Pramudantoro, Triaji Pangripto [1 ]
Badarudin, Apip [1 ]
Setyawan, Andriyanto [1 ]
Sumeru, Husain Akbar [2 ]
bin Sukri, Mohamad Firdaus [3 ]
Sulaimon, Shodiya [4 ]
机构
[1] Politeknik Negeri Bandung, Dept Refrigerat & Air Conditioning, Gegerkalong Hilir Ciwaruga, Bandung 40012, Indonesia
[2] Univ Padjadjaran, Dept Chem Ind Technol, Sumedang 45363, Indonesia
[3] Univ Teknikal Malaysia Melaka, Fac Mech Technol & Engn, Durian Tunggal 76100, Melaka, Malaysia
[4] Univ Maiduguri UNIMAID, Dept Mech Engn, Borno, Nigeria
关键词
Condensate; Cooling capacity; Discharge line; DX system; COP improvement; INTERNAL HEAT-EXCHANGER; WATER; NANOPARTICLES; DESIGN; PLANT; R134A; SIO2;
D O I
10.1016/j.csite.2024.105310
中图分类号
O414.1 [热力学];
学科分类号
摘要
The energy consumption by central air conditioning (A/C) in a building is very high and efforts to reduce this energy consumption is ongoing. This study investigates the use of condensate produced by the evaporator inside the air handling unit (AHU) to cool the compressor discharge line. A central A/C with a direct expansion (DX) system and a compressor capacity of about 25 HP which uses R22 as a working fluid was used. The discharge line has a diameter of 15.9 mm wrapped with a 520 mm long heat exchanger with diameter 50 mm. The condensate produced by the AHU is passed to the heat exchanger that envelops the discharge line. The use of discharge line cooler could reduce the input power from 18.21 kW to 17.54 kW. On the other hand, the cooling capacity increased from 46.44 kW to 49.11 kW. This means that discharge cooler reduces the input power by 3.8 % and increases the cooling capacity by 5.7 %. As a result, the COP increases by 9.8 %, from 2.5 to 2.8. The method developed is not complex and only simple modification is required, thus an improvement of the performance of a central A/C system can be achieved.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Effect of Compressor Discharge Cooling Using Condensate on Performance of Residential Air Conditioning System
    Sumeru, K.
    Sunardi, Cecep
    Sukri, M. F.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [2] Experimental investigation on the performance of residential air conditioning system using water condensate for subcooling
    Sumeru, Kasni
    Pramudantoro, Triaji Pangripto
    Setyawan, Andriyanto
    3RD ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2018), 2018, 197
  • [3] AUTOMOBILE AIR CONDITIONING SYSTEM PERFORMANCE EVALUATION
    DEADY, FW
    SAE TRANSACTIONS, 1969, 78 : 86 - &
  • [4] Development and analysis of air-conditioning condensate assisted compact cooler unit: a novel approach in condensate recovery
    Palanisamy Dhamodharan
    Bakthavatsalam Kannappan Ayalur
    Santhosh Kumar Annamalai
    Rajendran Prabakaran
    Sung Chul Kim
    Journal of Thermal Analysis and Calorimetry, 2024, 149 : 3303 - 3316
  • [5] Development and analysis of air-conditioning condensate assisted compact cooler unit: a novel approach in condensate recovery
    Dhamodharan, Palanisamy
    Ayalur, Bakthavatsalam Kannappan
    Annamalai, Santhosh Kumar
    Prabakaran, Rajendran
    Kim, Sung Chul
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (08) : 3303 - 3316
  • [6] Experimental study on the effect of condensate water on the performance of split air conditioning system
    Yang, Hua
    Pei, Na
    Liu, Liansheng
    Fan, Man
    Qin, Yue
    ENERGY REPORTS, 2021, 7 : 840 - 851
  • [7] Performance evaluation of an automobile air conditioning system using R134a
    Esen, Dilek Ozlem
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 4952 - 4958
  • [8] Enhancement of condensate water quantity and coefficient of performance of an air conditioning system: An experimental study
    Meher, Raghavarapu Satya
    Jaikumar, Sagari
    HEAT TRANSFER, 2021, 50 (05) : 4144 - 4151
  • [9] ANALYSIS OF THE ROTO-COOLER AIR-CONDITIONING SYSTEM
    HUANG, YM
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (06): : 367 - 372
  • [10] Effects of sub-cooler on cooling performance of variable refrigerant flow air conditioning system
    Tu, Qiu
    Zhang, Lina
    Cai, Wei
    Guo, Xiujuan
    Deng, Chenmian
    Zhang, Jie
    Wang, Bingjun
    APPLIED THERMAL ENGINEERING, 2017, 127 : 1152 - 1163