Development and analysis of air-conditioning condensate assisted compact cooler unit: a novel approach in condensate recovery

被引:0
|
作者
Palanisamy Dhamodharan
Bakthavatsalam Kannappan Ayalur
Santhosh Kumar Annamalai
Rajendran Prabakaran
Sung Chul Kim
机构
[1] Yeungnam University,Department of Information and Communication Engineering
[2] Yeungnam University,School of Mechanical Engineering
[3] National Institute of Technology,Department of Energy and Environment
[4] SRMIST,Department of Mechanical Engineering
[5] Ramapuram Campus,Department of Automobile Engineering
[6] Kongu Engineering College,undefined
[7] Perundurai,undefined
关键词
Air-conditioning; Condensate energy recovery; Compact cooler unit; Thermal comfort; Energy saving potential; Economic benefit;
D O I
暂无
中图分类号
学科分类号
摘要
In line with the waste-to-energy conservation strategies, the present study focuses on the design and analysis of a Compact Cooler Unit (CCU) that can efficiently make use of cold condensate generated from air-conditioning plants. Condensate from air conditioners with cooling capabilities of 115 kW and 175 kW, respectively, producing 23 Lh−1 and 35 Lh−1 at temperatures of 15 ℃ and 10 ℃, are used in the study to investigate cabin thermal comfort. Experimental and simulation studies are conducted to analyze the cooling performance of the CCU within a 6 m3 cabin under likely condensate temperatures. A TRNSYS model, incorporating Type 32 cooling components, assesses indoor parameters at water temperatures of 10 °C and 15 °C against EN ISO 7730:2005. Simulation studies confirmed that CCU performed better at 10 °C compared to 15 ℃, and an experiment was carried out at 10 ℃ to validate the simulation results. The simulated results had good agreement with the experiments with a variation of less than 5%. The results show that the CCU can achieve a saving of 37% with a recovered condensate quantity of 25 Lh−1 at 11 ℃, and a payback period of 4.4 years. Overall, this study provides valuable insights into the effective utilization of condensate as a sustainable resource for energy-efficient cooling in air-conditioned plants. It is recommended that CCU be fitted wherever the available condensate quantity would be more than 25 Lh−1, and it could be run along with a conventional chiller unit to achieve better thermal comfort with minimum energy consumption.
引用
收藏
页码:3303 / 3316
页数:13
相关论文
共 50 条
  • [1] Development and analysis of air-conditioning condensate assisted compact cooler unit: a novel approach in condensate recovery
    Dhamodharan, Palanisamy
    Ayalur, Bakthavatsalam Kannappan
    Annamalai, Santhosh Kumar
    Prabakaran, Rajendran
    Kim, Sung Chul
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (08) : 3303 - 3316
  • [2] Experimental and exergy analysis of air-conditioning condensate energy recovery in HVAC and cold storage units
    Dhamodharan, Palanisamy
    Bakthavatsalam, A. K.
    Prabakaran, Rajendran
    Choi, Gyu Sang
    Kim, Sung Chul
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 59
  • [3] Air-conditioning condensate recovery and applications-Current developments and challenges ahead
    Algarni, Salem
    Saleel, C. A.
    Mujeebu, M. Abdul
    SUSTAINABLE CITIES AND SOCIETY, 2018, 37 : 263 - 274
  • [4] Current state of research in air-conditioning condensate utilization and challenges: A review approach
    Dhamodharan, Palanisamy
    Ayalur, Bakthavatsalam Kannappan
    Prabakaran, Rajendran
    Kumar, A. Santhosh
    Choi, Gyu Sang
    Kim, Sung Chul
    APPLIED THERMAL ENGINEERING, 2023, 233
  • [5] Experimental study on heat recovery and utilization of air conditioning condensate
    Chen, Xiaoyu
    Liang, Yiting
    Yin, Linjian
    Cheng, Haifeng
    ENERGY REPORTS, 2024, 12 : 4004 - 4015
  • [6] ANALYSIS OF THE ROTO-COOLER AIR-CONDITIONING SYSTEM
    HUANG, YM
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (06): : 367 - 372
  • [7] Quantitative and qualitative characteristics of condensate water of home air-conditioning system in Iran
    Alipour, Vali
    Mahvi, Amir Hossein
    Rezaei, Leila
    DESALINATION AND WATER TREATMENT, 2015, 53 (07) : 1834 - 1839
  • [8] Performance evaluation of a central air conditioning system using condensate as a discharge line cooler
    Sumeru, Kasni
    Pramudantoro, Triaji Pangripto
    Badarudin, Apip
    Setyawan, Andriyanto
    Sumeru, Husain Akbar
    bin Sukri, Mohamad Firdaus
    Sulaimon, Shodiya
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 63
  • [9] Numerical study on the thermal performance of water flow window fed with air-conditioning condensate
    Chan, Lok Shun
    ENERGY, 2023, 263
  • [10] Development and testing of condensate assisted pre-cooling unit for improved indoor air quality in a computer laboratory
    Palanisamy, Dhamodharan
    Ayalur, Bakthavatsalam Kannappan
    BUILDING AND ENVIRONMENT, 2019, 163