Performance evaluation of a central air conditioning system using condensate as a discharge line cooler

被引:0
|
作者
Sumeru, Kasni [1 ]
Pramudantoro, Triaji Pangripto [1 ]
Badarudin, Apip [1 ]
Setyawan, Andriyanto [1 ]
Sumeru, Husain Akbar [2 ]
bin Sukri, Mohamad Firdaus [3 ]
Sulaimon, Shodiya [4 ]
机构
[1] Politeknik Negeri Bandung, Dept Refrigerat & Air Conditioning, Gegerkalong Hilir Ciwaruga, Bandung 40012, Indonesia
[2] Univ Padjadjaran, Dept Chem Ind Technol, Sumedang 45363, Indonesia
[3] Univ Teknikal Malaysia Melaka, Fac Mech Technol & Engn, Durian Tunggal 76100, Melaka, Malaysia
[4] Univ Maiduguri UNIMAID, Dept Mech Engn, Borno, Nigeria
关键词
Condensate; Cooling capacity; Discharge line; DX system; COP improvement; INTERNAL HEAT-EXCHANGER; WATER; NANOPARTICLES; DESIGN; PLANT; R134A; SIO2;
D O I
10.1016/j.csite.2024.105310
中图分类号
O414.1 [热力学];
学科分类号
摘要
The energy consumption by central air conditioning (A/C) in a building is very high and efforts to reduce this energy consumption is ongoing. This study investigates the use of condensate produced by the evaporator inside the air handling unit (AHU) to cool the compressor discharge line. A central A/C with a direct expansion (DX) system and a compressor capacity of about 25 HP which uses R22 as a working fluid was used. The discharge line has a diameter of 15.9 mm wrapped with a 520 mm long heat exchanger with diameter 50 mm. The condensate produced by the AHU is passed to the heat exchanger that envelops the discharge line. The use of discharge line cooler could reduce the input power from 18.21 kW to 17.54 kW. On the other hand, the cooling capacity increased from 46.44 kW to 49.11 kW. This means that discharge cooler reduces the input power by 3.8 % and increases the cooling capacity by 5.7 %. As a result, the COP increases by 9.8 %, from 2.5 to 2.8. The method developed is not complex and only simple modification is required, thus an improvement of the performance of a central A/C system can be achieved.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] PERFORMANCE EVALUATION OF AIR-CONDITIONING UNITS
    ALBASSAM, E
    MAHESHWARI, GP
    RENEWABLE ENERGY, 1994, 4 (07) : 873 - 878
  • [42] State space based modeling and performance evaluation of an air-conditioning system
    Kumar, Mahendra
    Kar, I. N.
    Ray, Anjan
    HVAC&R RESEARCH, 2008, 14 (05): : 797 - 816
  • [43] Performance Evaluation and Experimental Study of the Induction Radiant Air-conditioning System
    Si, Qiang
    Zhang, Xiaosong
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1795 - 1804
  • [44] Dynamic Simulation to the Operation of Central Air Conditioning System
    Wei Bing
    Tang Juan
    Wei Zhe
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 2, 2010, : 296 - 302
  • [45] A Central Air Conditioning System Design for Hotel in Guangzhou
    Wu, Zhou
    Yang, Fang
    Tian, Huifang
    Wang, Jingjing
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 1612 - +
  • [46] Performance improvements evaluation of an automobile air conditioning system using CO2 - propane mixture as a refrigerant
    Yu, Binbin
    Wang, Dandong
    Liu, Cichong
    Jiang, Fuzheng
    Shi, Junye
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 172 - 181
  • [47] Power saving in a central air conditioning system by using multiple PCMs integrated with fresh air path
    Soliman, Ahmed Saad
    Fouda, Mohamed Samir
    Cheng, Ping
    ENERGY AND BUILDINGS, 2023, 300
  • [48] Economic evaluation of cold air conditioning system
    Yang, H
    Li, R
    Xuan, ZY
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1619 - 1626
  • [49] Performance of a solar absorption air conditioning system
    Li, ZF
    Sumathy, K
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 362 - 369
  • [50] Performance assessment of a desiccant air-conditioning system combined with dew-point indirect evaporative cooler and PV/T
    Olmus, Umutcan
    Guzelel, Yunus Emre
    Pinar, Engin
    Ozbek, Arif
    Buyukalaca, Orhan
    SOLAR ENERGY, 2022, 231 : 566 - 577