Impact of wind farm integration on relay protection(3): Performance analysis for wind farm outgoing transformer protection

被引:12
|
作者
Xi'an Jiaotong University, Xi'an 710049, China [1 ]
不详 [2 ]
机构
关键词
D O I
10.3969/j.issn.1006-6047.2013.03.001
中图分类号
学科分类号
摘要
Simulative analysis shows that the short circuit current frequency of doubly-fed induction generator during low-voltage ride-through period deviates from the fundamental frequency according to the working conditions before the fault. When the transformer internal fault occurs, the differential action and braking currents of differential protection based on phasor values fluctuate widely and the action conditions of differential protection based on sample values are not satisfied at certain sampling points, resulting in the incorrect and instable operations. With an actual regional wind farm as an example, the off-line action performance of the main transformer protection of wind farm and the step-up transformer protection of wind power group is tested and analyzed on EMTDC platform, which shows that, the fast action of differential protection based on either phasor or sample values can not be ensured and the factors influencing the accurate operation of protections for wind farm outgoing transformers are generator type, operating condition, fault location, fault type and short circuit capacity ratio.
引用
收藏
相关论文
共 50 条
  • [1] Impact of wind farm integration on relay protection(7): Analysis of relay protection configuration for wind farm outgoing power grid
    Zhang, B. (bhzhang@mail.xjtu.edu.cn), 1600, Electric Power Automation Equipment Press (33):
  • [2] Impact of wind farm integration on relay protection(2): DFIG-based wind farm electromagnetic transient equivalent model
    Zhang, B. (bhzhang@mail.xjtu.edu.cn), 1600, Electric Power Automation Equipment Press (33):
  • [3] Design and evaluation of a wind farm protection relay
    Haslam, SJ
    Crossley, PA
    Jenkins, N
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1999, 146 (01) : 37 - 44
  • [4] Impact of DFIG-Based Wind Farm on Outgoing Transmission Line Protection
    Jin, Xiaoming
    Xiong, Qing
    Chen, Linhao
    Zhang, Baohui
    PROCEEDINGS OF THE 6TH INTERNATIONAL ASIA CONFERENCE ON INDUSTRIAL ENGINEERING AND MANAGEMENT INNOVATION: CORE THEORY AND APPLICATIONS OF INDUSTRIAL ENGINEERING, VOL 1, 2016, : 971 - 983
  • [5] Wind farm protection
    Qureshi, Waqar A.
    Nair, Nirmal-Kumar C.
    Green Energy and Technology, 2014, : 311 - 329
  • [6] Impact Analyses of Wind Farm on Performances of Transmission Line Relay Protection
    Jin WANG Baohui ZHANG School of Electrical EngineeringXian Jiaotong UniversityXian China
    电力系统自动化, 2012, 36 (08) : 148 - 153
  • [7] Impact analyses of wind farm on performances of transmission line relay protection
    Wang, Jin
    Zhang, Baohui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (08): : 148 - 153
  • [8] Modeling and Simulation on Transformer Computer Protection in Wind Farm
    Tian, De
    Song, Haihui
    INDUSTRIAL DESIGN AND MECHANICS POWER II, 2013, 437 : 173 - 176
  • [9] Research of Impact of The Direct Drive Wind Farm on Power System Relay Protection
    Zhou Shenghai
    Gu Ying
    Song Wei
    Wang Chong
    Bai Feng
    Wang Yuqiang
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [10] Doubly-Fed Wind Farm Outgoing Transformer Differential Protection Based on Excitation Inductance Calculation
    Sun, Dejuan
    Sun, Shiyun
    Fan, Xiaohong
    Hai, Shifang
    Wang, Yang
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (02): : 395 - 407