Impact of wind farm integration on relay protection(3): Performance analysis for wind farm outgoing transformer protection

被引:12
|
作者
Xi'an Jiaotong University, Xi'an 710049, China [1 ]
不详 [2 ]
机构
关键词
D O I
10.3969/j.issn.1006-6047.2013.03.001
中图分类号
学科分类号
摘要
Simulative analysis shows that the short circuit current frequency of doubly-fed induction generator during low-voltage ride-through period deviates from the fundamental frequency according to the working conditions before the fault. When the transformer internal fault occurs, the differential action and braking currents of differential protection based on phasor values fluctuate widely and the action conditions of differential protection based on sample values are not satisfied at certain sampling points, resulting in the incorrect and instable operations. With an actual regional wind farm as an example, the off-line action performance of the main transformer protection of wind farm and the step-up transformer protection of wind power group is tested and analyzed on EMTDC platform, which shows that, the fast action of differential protection based on either phasor or sample values can not be ensured and the factors influencing the accurate operation of protections for wind farm outgoing transformers are generator type, operating condition, fault location, fault type and short circuit capacity ratio.
引用
收藏
相关论文
共 50 条
  • [41] Wind Farm Collector Protection using Directional Overcurrent Elements
    Jones, Doug
    Bennett, Kyle
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [42] An adaptive relaying for the protection of a wind farm interconnected with distribution networks
    Jang, SI
    Choi, JH
    Kim, JW
    Choi, DM
    Kim, KH
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 296 - 302
  • [43] Configuration and Setting of Protection for Large-scale Wind Farm
    Li, Y. B.
    Bi, T. S.
    Zheng, T. Y.
    Wang, J. X.
    Ma, L. H.
    Liu, D. P.
    Liu, S. M.
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 1008 - 1013
  • [44] Fault characteristics and protection adaptability analysis in VSC-HVDC-connected offshore wind farm integration system
    Jia, Ke
    Chen, Rui
    Xuan, Zhenwen
    Yang, Zhe
    Fang, Yu
    Bi, Tianshu
    IET RENEWABLE POWER GENERATION, 2018, 12 (13) : 1547 - 1554
  • [45] Strategic Environmental Assessment in the Application of Preventive Protection for Wind Farm Noise-Case Study: Maestrale Ring Wind Farm
    Josimovic, Bosko D.
    Cvjetic, Aleksandar
    Manic, Bozidar
    ENERGIES, 2021, 14 (19)
  • [46] PERFORMANCE ANALYSIS OF WIND FARM WITH DIFFERENT LAYOUTS
    Kaushik, Manisha
    Sandhu, K. S.
    PROCEEDINGS OF THE 2018 SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL SYSTEMS (ICICCS), 2018, : 1625 - 1630
  • [47] Wind Farm Integration in a Harmonic Environment
    Dang, Michael N. D.
    Al-Mutawaly, Nafia
    Sztur, Peter
    Coenen, Mark
    2015 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2015, : 1 - 7
  • [48] A novel protection method for a wind farm collector line based on FCM clustering analysis
    Yu, Kun
    Liu, Zhanlei
    Zhao, Guoxuan
    Li, Jiazheng
    Zeng, Xiangjun
    Wang, Zhan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 129
  • [49] Multiterminal DC Wind Farm Collection Grid Internal Fault Analysis and Protection Design
    Yang, Jin
    Fletcher, John Edward
    O'Reilly, John
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2308 - 2318
  • [50] Investigating the impact of a dynamic thermal rating on wind farm integration
    Dawson, Leanne
    Knight, Andrew M.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (10) : 2449 - 2457