Impact of wind farm integration on relay protection(3): Performance analysis for wind farm outgoing transformer protection

被引:12
|
作者
Xi'an Jiaotong University, Xi'an 710049, China [1 ]
不详 [2 ]
机构
关键词
D O I
10.3969/j.issn.1006-6047.2013.03.001
中图分类号
学科分类号
摘要
Simulative analysis shows that the short circuit current frequency of doubly-fed induction generator during low-voltage ride-through period deviates from the fundamental frequency according to the working conditions before the fault. When the transformer internal fault occurs, the differential action and braking currents of differential protection based on phasor values fluctuate widely and the action conditions of differential protection based on sample values are not satisfied at certain sampling points, resulting in the incorrect and instable operations. With an actual regional wind farm as an example, the off-line action performance of the main transformer protection of wind farm and the step-up transformer protection of wind power group is tested and analyzed on EMTDC platform, which shows that, the fast action of differential protection based on either phasor or sample values can not be ensured and the factors influencing the accurate operation of protections for wind farm outgoing transformers are generator type, operating condition, fault location, fault type and short circuit capacity ratio.
引用
收藏
相关论文
共 50 条
  • [21] The Transient Distance Protection on Wind Farm Transmission Line with Crowbar Protection
    Zhang, Xingyu
    Lu, Yuping
    Shi, Dongmin
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 366 - 371
  • [22] Analysis on Transformer Protection Maloperation Caused by Single-phase Tripping of Wind Farm Transmission Lines
    Luo, Yiping
    Zhang, Chun
    Yang, Qi
    Xiang, Bo
    Li, Xiaopeng
    Zhou, Wenyue
    2024 7TH ASIA CONFERENCE ON ENERGY AND ELECTRICAL ENGINEERING, ACEEE 2024, 2024, : 219 - 223
  • [23] Optimal sizing of the wind farm and wind farm transformer using MILP and dynamic transformer rating
    Gomez, Andrea Molina
    Morozovska, Kateryna
    Laneryd, Tor
    Hilber, Patrik
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 136
  • [24] Overcurrent Protection Behavior Before Wind Farm Contribution
    Comech, M. P.
    Montanes, M. A.
    Garcia, Gracia
    2008 IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 2008, : 741 - 746
  • [25] Surface protection of offshore wind-farm installations
    Stenzel, Volkmar
    Plagemann, Peter
    Momber, Andreas
    Galvanotechnik, 2007, 98 (10): : 2508 - 2513
  • [26] A zoning protection scheme for distribution system with wind farm
    Li, Fengting
    Energy Education Science and Technology Part A: Energy Science and Research, 2014, 32 (05): : 4035 - 4050
  • [27] Dynamic Line Rating Protection for Wind Farm Connections
    Yip, Tony
    An, Chang
    Lloyd, Graeme
    Aten, Martin
    Ferris, Bob
    2009 CIGRE/IEEE PES JOINT SYMPOSIUM INTEGRATION OF WIDE-SCALE RENEWABLE RESOURCES INTO THE POWER DELIVERY SYSTEM, 2009, : 330 - 334
  • [28] An FPGA-based Cost-effective Digital Differential Relay for Wind Farm Protection
    Uddin, M. Nasir
    Rezaei, Nima
    2020 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2020,
  • [29] Influence on Transmission Line Relay Protection under DFIG-based wind farm intergration
    Gao Feng
    Guan Zhe
    Zhang Shuang
    Zhang Jun
    Dou Jingming
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 290 - 295
  • [30] Identifying Inrush Current for Wind Farm Outgoing Transformer Based on MEMD-MMFE
    Li C.
    Zhou N.
    Liao J.
    Wang Q.
    Meng X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (17): : 5061 - 5073