Wind farm protection

被引:0
|
作者
Qureshi, Waqar A. [1 ]
Nair, Nirmal-Kumar C. [1 ]
机构
[1] Department of Electrical and Computer Engineering, Science Centre, University of Auckland, 38 Princes Street, Building 303, Auckland 1142, New Zealand
关键词
Electric power transmission networks - Electric power transmission - Quality control - Electric utilities - Electric equipment protection - Electric power system protection - Turbogenerators - Electric fault currents - Wind farm - Electric power system interconnection;
D O I
10.1007/978-981-4585-30-9_12
中图分类号
学科分类号
摘要
Transmission system operation with wind generators has been well analyzed for issues like forecasting, reliability, control, power quality, and fault ride through (FRT) impacts following large-scale integration. However, there are still no standardized protection schemes for wind farms such as those practiced for the protection of conventional generation plants. Wind generators' collective response under high penetration scenarios needs special attention especially under abnormal operations such as grid disturbances and faults. During abnormal grid situations like faults, protection requirements for wind farms depend on a variety of factors. Different wind generation technologies exhibit different dynamic characteristics compared to conventional synchronous generator plants. Network characteristics and their interaction with available wind technologies also impact the fault behavior. This chapter first comprehensively reviews the integration characteristics and criteria for three different wind generator technologies connected to high voltage (HV) transmission systems. Aspects such as selection of time step and impact of additional controls such as crowbar protection are also discussed with their possible impacts on fault current estimation. A case study in Dig SILENT® Power Factory has been developed to assess and compare the fault response of wind generator technology types. The response of each WTG type is generalized and analyzed in time domain to determine the number of electrical frequency cycles before the fault current reaches to steady-state value. Based on the estimated number of cycles and in the scenario of weaker interconnecting grids, protection schemes performance and protection relay operation are mainly assessed for each wind turbine generator (WTG) type. Technical challenges and difficulties are also highlighted before concluding. © Springer Science+Business Media Singapore 2014.
引用
收藏
页码:311 / 329
相关论文
共 50 条
  • [1] Protection for a Wind Turbine Generator in a Large Wind Farm
    Zheng, Tai-Ying
    Kim, Yeon-Hee
    Kang, Yong-Cheol
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2011, 6 (04) : 466 - 473
  • [2] Study on adaptive protection of wind farm
    Wen, Yu-Ling
    Chao, Qin
    Tuerxun, Yibulayin
    Liu, Jun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (05): : 47 - 51
  • [3] Impact of wind farm integration on relay protection(3): Performance analysis for wind farm outgoing transformer protection
    Xi'an Jiaotong University, Xi'an 710049, China
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2013, 3 (1-8):
  • [4] Protection algorithm for a wind turbine generator in a large wind farm
    Zheng, T.Y.
    Kim, Y.H.
    Crossley, P.A.
    Kang, Y.C.
    2011 IEEE PES Trondheim PowerTech: The Power of Technology for a Sustainable Society, POWERTECH 2011, 2011,
  • [5] Design and evaluation of a wind farm protection relay
    Haslam, SJ
    Crossley, PA
    Jenkins, N
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1999, 146 (01) : 37 - 44
  • [6] Challenges and issues involved in wind farm protection
    Mahadanaarachchi, V. P.
    Ramakumar, R.
    40TH ANNUAL FRONTIERS OF POWERS CONFERENCE, PROCEEDINGS, 2007, : U217 - +
  • [7] Impact of wind farm integration on relay protection(7): Analysis of relay protection configuration for wind farm outgoing power grid
    Zhang, B. (bhzhang@mail.xjtu.edu.cn), 1600, Electric Power Automation Equipment Press (33):
  • [8] The Transient Distance Protection on Wind Farm Transmission Line with Crowbar Protection
    Zhang, Xingyu
    Lu, Yuping
    Shi, Dongmin
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 366 - 371
  • [9] Overcurrent Protection Behavior Before Wind Farm Contribution
    Comech, M. P.
    Montanes, M. A.
    Garcia, Gracia
    2008 IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 2008, : 741 - 746
  • [10] Modeling and Simulation on Transformer Computer Protection in Wind Farm
    Tian, De
    Song, Haihui
    INDUSTRIAL DESIGN AND MECHANICS POWER II, 2013, 437 : 173 - 176