Performance prediction of three sides hemispherical dimple roughened solar duct

被引:0
|
作者
Kumar V. [1 ]
Prasad L. [2 ]
机构
[1] Dept. of Mechanical Engineering, Malla Reddy College of Engineering, Secunderabad
[2] Dept. of Mechanical Engineering, NIT Jamshedpur, Jharkhand
来源
Instrumentation Mesure Metrologie | 2018年 / 17卷 / 02期
关键词
Concave dimple; One and three sides roughened duct; Relative roughness height relative roughness pitch; Solar air heater;
D O I
10.3166/I2M.17.273-293
中图分类号
学科分类号
摘要
The present paper deals with the results of experimental investigation conducted upon one and three sides concave dimple roughened solar air heater ducts and examine the effects of roughness and flow parameters on thermal efficiency results. The present investigation is carried under the Reynolds number range of 2500-12500, relative roughness pitch of 8-15 and relative roughness height of 0.018-0.045. The augmentation in fluid (air) temperature flowing under three sides concave dimple roughened duct is found to be 34.87% more than one side roughened duct. The plate temperature excess range for three sides roughened duct is significantly lower (12.5-28.5C) compared to one side roughened duct (17.5-35.5C). The maximum thermal efficiency is obtained at relative roughness pitch of 12 and relative roughness height of 0.036. The augmentation in thermal efficiency of three sides over those of one side roughened duct is found to be 44-56 % for varying p/e and 39-51 % for varying e/Dh. © 2018 Lavoisier.
引用
收藏
页码:273 / 293
页数:20
相关论文
共 50 条
  • [41] OPTIMAL THERMOHYDRAULIC PERFORMANCE OF ARTIFICIALLY ROUGHENED SOLAR AIR HEATERS
    PRASAD, BN
    SAINI, JS
    SOLAR ENERGY, 1991, 47 (02) : 91 - 96
  • [42] A review of thermohydraulic performance of artificially roughened solar air heaters
    Kumar, Anil
    Saini, R. P.
    Saini, J. S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 37 : 100 - 122
  • [43] Effect of apex angle variation on thermal and hydraulic performance of roughened triangular duct
    Goel, Varun
    Guleria, Pankaj
    Kumar, Rajneesh
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 86 : 239 - 244
  • [44] Thermohydraulic performance of solar air heaters with roughened absorber plates
    Gupta, D
    Solanki, SC
    Saini, JS
    SOLAR ENERGY, 1997, 61 (01) : 33 - 42
  • [45] Analytical investigation of jet impingement solar air heater with dimple-roughened absorber surface via thermal and effective analysis
    Salman, Mohammad
    Chauhan, Ranchan
    Poongavanam, Ganesh Kumar
    Kim, Sung Chul
    RENEWABLE ENERGY, 2022, 199 : 1248 - 1257
  • [46] Heat Transfer and Friction Characteristics of Artificially Roughened Duct used for Solar Air Heaters—a Review
    Kumar K.
    Prajapati D.R.
    Samir S.
    Journal of The Institution of Engineers (India): Series C, 2018, 99 (1) : 105 - 123
  • [47] Solar air heater duct roughened with wavy delta winglets: correlations development and parametric optimization
    Rajesh Maithani
    Sunil Chamoli
    Anil Kumar
    Ashutosh Gupta
    Heat and Mass Transfer, 2019, 55 : 3473 - 3491
  • [48] Experimental investigations on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct
    Bopche, Santosh B.
    Tandale, Madhukar S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (11-12) : 2834 - 2848
  • [49] Solar air heater duct roughened with wavy delta winglets: correlations development and parametric optimization
    Maithani, Rajesh
    Chamoli, Sunil
    Kumar, Anil
    Gupta, Ashutosh
    HEAT AND MASS TRANSFER, 2019, 55 (12) : 3473 - 3491
  • [50] Exergy analysis of roughened duct using multiple arcs with gaps used in solar air heaters
    Pandey, Navneet Kumar
    Bajpai, V. K.
    Sharma, Abhishek
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 43 (01) : 4129 - 4137