Effect of apex angle variation on thermal and hydraulic performance of roughened triangular duct

被引:27
|
作者
Goel, Varun [1 ]
Guleria, Pankaj [2 ]
Kumar, Rajneesh [1 ]
机构
[1] Natl Inst Technol, Hamirpur 177005, HP, India
[2] Bhushan Steels, Dhenkanal, Orissa, India
关键词
Apex angle; Dimple shaped roughness; Triangular duct; Correlation; HEAT-TRANSFER; FORCED-CONVECTION; FRICTION CHARACTERISTICS; FLOW-THROUGH; ROUGHNESS ELEMENT; PRESSURE-DROP; LAMINAR;
D O I
10.1016/j.icheatmasstransfer.2017.06.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The experiments were performed to analyze the influence of apex angle on thermal and hydraulic characteristics of triangular duct for Reynolds number range from 2000 to 16,000. Four different triangular ducts of apex angle 30 degrees, 60 degrees, 90 degrees and 110 degrees were fabricated for the experimentation. The one side of the duct is roughened with dimple shaped roughness element. The both relative shortway length (s/e) and relative longway length (l/e) of dimple shaped roughened element was kept constant (i.e., 10) but relative roughness height (e/D) is varied from 0.016 to 0.038. Result shows that apex angle plays an important role in heat transfer. The experimental results are presented in a form of correlation for Nusselt number (Nu) and friction factor (f).
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [1] CFD Analysis on the Thermal Hydraulic Performance of an SAH Duct with Multi V-Shape Roughened Ribs
    Kumar, Anil
    Kim, Man-Hoe
    ENERGIES, 2016, 9 (06):
  • [2] Exergetic performance estimation for roughened triangular duct used in solar air heaters
    Kumar, Sunil
    Kumar, Rajneesh
    Goel, Varun
    Bhattacharyya, Suvanjan
    Issakhov, Alibek
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (03) : 1661 - 1672
  • [3] Exergetic performance estimation for roughened triangular duct used in solar air heaters
    Sunil Kumar
    Rajneesh Kumar
    Varun Goel
    Suvanjan Bhattacharyya
    Alibek Issakhov
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 1661 - 1672
  • [4] Comparative study of effect of various blockage arrangements on thermal hydraulic performance in a roughened air passage
    Kumar, Raj
    Kumar, Anil
    Chauhan, Ranchan
    Maithani, Rajesh
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 : 447 - 463
  • [5] FULLY-DEVELOPED TURBULENT MASS-TRANSFER IN A TRIANGULAR DUCT WITH A NARROW APEX ANGLE
    USUI, H
    YANAGI, M
    ENDOH, A
    SANO, Y
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1983, 16 (02) : 103 - 109
  • [6] Thermo-hydraulic performance of rectangular channel roughened with combined semi-circular and triangular ribs
    Sahu, M. K.
    Pandey, K. M.
    Chatterjee, S.
    HEAT AND MASS TRANSFER, 2019, 55 (10) : 2889 - 2900
  • [7] Thermo-hydraulic performance of rectangular channel roughened with combined semi-circular and triangular ribs
    M. K. Sahu
    K. M. Pandey
    S. Chatterjee
    Heat and Mass Transfer, 2019, 55 : 2889 - 2900
  • [8] TURBULENCE MEASUREMENTS AND MASS-TRANSFER IN FULLY-DEVELOPED FLOW IN A TRIANGULAR DUCT WITH A NARROW APEX ANGLE
    USUI, H
    SANO, Y
    FUKUMA, H
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1982, 25 (05) : 615 - 624
  • [9] Effect of duct length variation on solar air heater performance for smooth and D-shaped roughened absorber plate
    Dutt, Nitesh
    Hedau, Ankush
    Kumar, Ashwani
    Awasthi, Mukesh Kumar
    Singh, Varun Pratap
    HEAT TRANSFER, 2024, 53 (07) : 3902 - 3930
  • [10] A study on the effect of fin pitch variation on the thermal performance of a bus duct conductor
    Selvan, Mark
    Aziz, Mohd Sharizal Abdul
    Yu, Kok Hwa
    Nurulakmal, M. S.
    Ong, H. P.
    Khor, C. Y.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 184