Effect of apex angle variation on thermal and hydraulic performance of roughened triangular duct

被引:27
|
作者
Goel, Varun [1 ]
Guleria, Pankaj [2 ]
Kumar, Rajneesh [1 ]
机构
[1] Natl Inst Technol, Hamirpur 177005, HP, India
[2] Bhushan Steels, Dhenkanal, Orissa, India
关键词
Apex angle; Dimple shaped roughness; Triangular duct; Correlation; HEAT-TRANSFER; FORCED-CONVECTION; FRICTION CHARACTERISTICS; FLOW-THROUGH; ROUGHNESS ELEMENT; PRESSURE-DROP; LAMINAR;
D O I
10.1016/j.icheatmasstransfer.2017.06.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The experiments were performed to analyze the influence of apex angle on thermal and hydraulic characteristics of triangular duct for Reynolds number range from 2000 to 16,000. Four different triangular ducts of apex angle 30 degrees, 60 degrees, 90 degrees and 110 degrees were fabricated for the experimentation. The one side of the duct is roughened with dimple shaped roughness element. The both relative shortway length (s/e) and relative longway length (l/e) of dimple shaped roughened element was kept constant (i.e., 10) but relative roughness height (e/D) is varied from 0.016 to 0.038. Result shows that apex angle plays an important role in heat transfer. The experimental results are presented in a form of correlation for Nusselt number (Nu) and friction factor (f).
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [31] Thermal-hydraulic performance of solar receiver duct with inclined punched-ribs and grooves
    Jayranaiwachira, Nuthvipa
    Promvonge, Pongjet
    Thianpong, Chinaruk
    Skullong, Sompol
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [32] Effect of a Slotted Shield on Thermal and Hydraulic Performance of a Heat Sink
    Elsayed, Mohamed L.
    Mesalhy, Osama
    JOURNAL OF ELECTRONIC PACKAGING, 2015, 137 (01)
  • [33] Effect of 450 protruded and dimpled rib height on the performance of triangular duct solar heat collector
    Kumar, Anil
    Maithani, Rajesh
    Yadav, Anil Singh
    Sharma, Sachin
    MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 253 - 258
  • [34] Enhanced thermo-hydraulic performance in a V-ribbed triangular duct solar air heater: CFD and exergy analysis
    Nidhul, Kottayat
    Kumar, Sachin
    Yadav, Ajay Kumar
    Anish, S.
    ENERGY, 2020, 200
  • [35] A CFD based thermo-hydraulic performance analysis of an artificially roughened solar air heater having equilateral triangular sectioned rib roughness on the absorber plate
    Yadav, Anil Singh
    Bhagoria, J. L.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 70 : 1016 - 1039
  • [36] Thermal performance analysis of triangular solar air heater duct having broken V-shaped ribs
    Agrawal R.K.
    Prasad R.S.
    International Journal of Ambient Energy, 2024, 45 (01)
  • [37] Analysis of hydrodynamics and thermal-hydraulic performance of twisted angle fins within an annular conduit
    Haw, W.
    Oon, C. S.
    Lau, E. V.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025, 150 (01) : 377 - 394
  • [38] Investigation of the Effect of a Coolant Inlet Duct on the Thermal Performance of Car Radiators
    Petrik, Mate
    Szepesi, Gabor L.
    VEHICLE AND AUTOMOTIVE ENGINEERING 4, VAE2022, 2023, : 339 - 345
  • [39] EFFECT OF GEOMETRY AND IMPEDANCE VARIATION ON THE ACOUSTIC PERFORMANCE OF A POROUS MATERIAL LINED DUCT
    Masmoudi, Abdelmonem
    Makni, Amine
    Taktak, Mohamed
    Haddar, Mohamed
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2017, 55 (02) : 679 - 694
  • [40] Experimental and numerical study on thermal performance of new envelope and triangular vortex generators with different pitch and angle of attack
    Srivastava, Kartik
    Sahoo, Rashmi Rekha
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 49