Performance prediction of three sides hemispherical dimple roughened solar duct

被引:0
|
作者
Kumar V. [1 ]
Prasad L. [2 ]
机构
[1] Dept. of Mechanical Engineering, Malla Reddy College of Engineering, Secunderabad
[2] Dept. of Mechanical Engineering, NIT Jamshedpur, Jharkhand
来源
Instrumentation Mesure Metrologie | 2018年 / 17卷 / 02期
关键词
Concave dimple; One and three sides roughened duct; Relative roughness height relative roughness pitch; Solar air heater;
D O I
10.3166/I2M.17.273-293
中图分类号
学科分类号
摘要
The present paper deals with the results of experimental investigation conducted upon one and three sides concave dimple roughened solar air heater ducts and examine the effects of roughness and flow parameters on thermal efficiency results. The present investigation is carried under the Reynolds number range of 2500-12500, relative roughness pitch of 8-15 and relative roughness height of 0.018-0.045. The augmentation in fluid (air) temperature flowing under three sides concave dimple roughened duct is found to be 34.87% more than one side roughened duct. The plate temperature excess range for three sides roughened duct is significantly lower (12.5-28.5C) compared to one side roughened duct (17.5-35.5C). The maximum thermal efficiency is obtained at relative roughness pitch of 12 and relative roughness height of 0.036. The augmentation in thermal efficiency of three sides over those of one side roughened duct is found to be 44-56 % for varying p/e and 39-51 % for varying e/Dh. © 2018 Lavoisier.
引用
收藏
页码:273 / 293
页数:20
相关论文
共 50 条
  • [31] Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs
    Deo, Narinderpal Singh
    Chander, Subhash
    Saini, J. S.
    RENEWABLE ENERGY, 2016, 91 : 484 - 500
  • [32] Design and performance of a transportable hemispherical solar still
    Ismail, Basel I.
    RENEWABLE ENERGY, 2009, 34 (01) : 145 - 150
  • [33] Review and performance evaluation of roughened solar air heaters
    Bisht, Vijay Singh
    Patil, Anil Kumar
    Gupta, Anirudh
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 : 954 - 977
  • [34] Thermal performance of artificially roughened solar air heaters
    Prasad, B. N.
    SOLAR ENERGY, 2013, 91 : 59 - 67
  • [35] A numerical method to calculate the cooling performance of a rib-roughened duct
    Abdon, A
    Sundén, B
    ADVANCED COMPUTATIONAL METHODS IN HEAT TRANSFER V, 1998, : 381 - 391
  • [36] Optimization of artificial roughness parameters in a solar air heater duct roughened with hybrid ribs
    Gill, Raminder Singh
    Hans, Vishavjeet Singh
    Singh, Rupinder Pal
    APPLIED THERMAL ENGINEERING, 2021, 191
  • [37] Performance Evaluation of Roughened Solar Air Heaters for Stretched Parameters
    Alaskari, Mustafa
    Kadhim, Arwa M.
    Farhan, Ammar A.
    Al-Damook, Moustafa
    Al Qubeissi, Mansour
    CLEAN TECHNOLOGIES, 2022, 4 (02): : 555 - 569
  • [38] Performance of artificially roughened solar air heaters-A review
    Hans, Vishavjeet Singh
    Saini, R. P.
    Saini, J. S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (08): : 1854 - 1869
  • [39] THERMAL PERFORMANCE IMPROVEMENT OF ARTIFICIALLY ROUGHENED SOLAR AIR HEATER
    Bader, Nabaa M.
    Mushatet, Khudheyer S.
    ENGINEERING REVIEW, 2023, 43 (01) : 66 - 81
  • [40] Thermal performance investigation of frustum roughened solar air heater
    Singh, Dharam
    Kumar, Vikash
    SOLAR ENERGY, 2023, 255 : 339 - 354